22964e192b
- New MxGateway:Worker:WorkerHeartbeatGraceSeconds (default 15), exported as MXGATEWAY_WORKER_HEARTBEAT_GRACE_MS and read by WorkerPipeSessionOptions.FromEnvironment (a grace the ceiling does not exceed falls back to the default so the worker still starts). Validation now checks WorkerHeartbeatStuckCeilingSeconds against the configured grace; the copied WorkerWatchdogGraceSeconds constant is gone. - EffectiveWorkerConfiguration and the dashboard Settings page now show the worker heartbeat send interval, watchdog grace and stuck ceiling (render test added). - Docs updated. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
98 lines
4.4 KiB
C#
98 lines
4.4 KiB
C#
using System;
|
|
using System.Collections.Generic;
|
|
using ZB.MOM.WW.MxGateway.Contracts;
|
|
using ZB.MOM.WW.MxGateway.Worker.Ipc;
|
|
|
|
namespace ZB.MOM.WW.MxGateway.Worker.Tests.Ipc;
|
|
|
|
/// <summary>
|
|
/// Covers <see cref="WorkerPipeSessionOptions.FromEnvironment"/>: the gateway conveys the
|
|
/// worker's heartbeat send interval and watchdog stuck ceiling through the launch environment
|
|
/// (mxaccessgw#218), and a bad value must fall back rather than keep the worker from starting.
|
|
/// </summary>
|
|
public sealed class WorkerPipeSessionOptionsTests
|
|
{
|
|
/// <summary>Verifies that launcher-provided values replace the compiled defaults.</summary>
|
|
[Fact]
|
|
public void FromEnvironment_WithLauncherValues_UsesThem()
|
|
{
|
|
WorkerPipeSessionOptions options = WorkerPipeSessionOptions.FromEnvironment(Lookup(
|
|
(WorkerLaunchEnvironment.HeartbeatSendIntervalMilliseconds, "3000"),
|
|
(WorkerLaunchEnvironment.HeartbeatStuckCeilingMilliseconds, "240000")));
|
|
|
|
Assert.Equal(TimeSpan.FromSeconds(3), options.HeartbeatInterval);
|
|
Assert.Equal(TimeSpan.FromSeconds(240), options.HeartbeatStuckCeiling);
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatGrace, options.HeartbeatGrace);
|
|
options.Validate();
|
|
}
|
|
|
|
/// <summary>Verifies that a launcher-provided grace replaces the compiled default (mxaccessgw#224).</summary>
|
|
[Fact]
|
|
public void FromEnvironment_WithGrace_UsesItAndStaysValid()
|
|
{
|
|
WorkerPipeSessionOptions options = WorkerPipeSessionOptions.FromEnvironment(Lookup(
|
|
(WorkerLaunchEnvironment.HeartbeatGraceMilliseconds, "30000"),
|
|
(WorkerLaunchEnvironment.HeartbeatStuckCeilingMilliseconds, "120000")));
|
|
|
|
Assert.Equal(TimeSpan.FromSeconds(30), options.HeartbeatGrace);
|
|
Assert.Equal(TimeSpan.FromSeconds(120), options.HeartbeatStuckCeiling);
|
|
options.Validate();
|
|
}
|
|
|
|
/// <summary>Verifies that a grace the ceiling does not exceed is dropped rather than failing the worker.</summary>
|
|
[Fact]
|
|
public void FromEnvironment_WithGraceAtOrAboveCeiling_FallsBackToDefaultGrace()
|
|
{
|
|
WorkerPipeSessionOptions options = WorkerPipeSessionOptions.FromEnvironment(Lookup(
|
|
(WorkerLaunchEnvironment.HeartbeatGraceMilliseconds, "80000")));
|
|
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatGrace, options.HeartbeatGrace);
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatStuckCeiling, options.HeartbeatStuckCeiling);
|
|
options.Validate();
|
|
}
|
|
|
|
/// <summary>Verifies that an absent environment yields the compiled defaults.</summary>
|
|
[Fact]
|
|
public void FromEnvironment_WithNothingSet_KeepsDefaults()
|
|
{
|
|
WorkerPipeSessionOptions options = WorkerPipeSessionOptions.FromEnvironment(Lookup());
|
|
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatInterval, options.HeartbeatInterval);
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatStuckCeiling, options.HeartbeatStuckCeiling);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Verifies that unusable values fall back to the defaults, including a ceiling that would
|
|
/// fail <see cref="WorkerPipeSessionOptions.Validate"/> by not exceeding the grace.
|
|
/// </summary>
|
|
/// <param name="interval">Send-interval environment value.</param>
|
|
/// <param name="ceiling">Stuck-ceiling environment value.</param>
|
|
[Theory]
|
|
[InlineData("0", "0")]
|
|
[InlineData("-5", "-5")]
|
|
[InlineData("abc", "1.5")]
|
|
[InlineData("", "15000")]
|
|
[InlineData("99999999999", "99999999999")]
|
|
public void FromEnvironment_WithUnusableValues_FallsBackToDefaults(string interval, string ceiling)
|
|
{
|
|
WorkerPipeSessionOptions options = WorkerPipeSessionOptions.FromEnvironment(Lookup(
|
|
(WorkerLaunchEnvironment.HeartbeatSendIntervalMilliseconds, interval),
|
|
(WorkerLaunchEnvironment.HeartbeatStuckCeilingMilliseconds, ceiling)));
|
|
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatInterval, options.HeartbeatInterval);
|
|
Assert.Equal(WorkerPipeSessionOptions.DefaultHeartbeatStuckCeiling, options.HeartbeatStuckCeiling);
|
|
options.Validate();
|
|
}
|
|
|
|
private static Func<string, string?> Lookup(params (string Name, string Value)[] values)
|
|
{
|
|
Dictionary<string, string> map = new(StringComparer.Ordinal);
|
|
foreach ((string name, string value) in values)
|
|
{
|
|
map[name] = value;
|
|
}
|
|
|
|
return name => map.TryGetValue(name, out string? value) ? value : null;
|
|
}
|
|
}
|