dc9c0c950c
Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.
External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths
Also fixes two tests that were not rename-related but became visible
while validating the rename:
- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
gateway service correctly maps to RpcException(Cancelled) per gRPC
convention was being misclassified as a stream fault. Added a sibling
catch on RpcException with StatusCode.Cancelled.
- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
and made it accept either a .git marker OR a .sln/.slnx next to src/
so the worker-exe walker works in non-git working copies.
clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.
Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
Tests: 472/472 pass
Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
IntegrationTests: 18/18 pass
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
39 lines
1.8 KiB
C#
39 lines
1.8 KiB
C#
namespace ZB.MOM.WW.MxGateway.Server.Configuration;
|
|
|
|
public sealed class WorkerOptions
|
|
{
|
|
/// <summary>The path to the worker executable.</summary>
|
|
public string ExecutablePath { get; init; } =
|
|
@"src\ZB.MOM.WW.MxGateway.Worker\bin\x86\Release\ZB.MOM.WW.MxGateway.Worker.exe";
|
|
|
|
/// <summary>The working directory for the worker process, or null to inherit.</summary>
|
|
public string? WorkingDirectory { get; init; }
|
|
|
|
/// <summary>The required processor architecture for the worker.</summary>
|
|
public WorkerArchitecture RequiredArchitecture { get; init; } = WorkerArchitecture.X86;
|
|
|
|
/// <summary>The maximum time in seconds for the worker to start.</summary>
|
|
public int StartupTimeoutSeconds { get; init; } = 30;
|
|
|
|
/// <summary>The number of retry attempts for the startup probe.</summary>
|
|
public int StartupProbeRetryAttempts { get; init; } = 3;
|
|
|
|
/// <summary>The delay in milliseconds between startup probe retries.</summary>
|
|
public int StartupProbeRetryDelayMilliseconds { get; init; } = 250;
|
|
|
|
/// <summary>The timeout in milliseconds for connecting to the worker pipe.</summary>
|
|
public int PipeConnectAttemptTimeoutMilliseconds { get; init; } = 2000;
|
|
|
|
/// <summary>The maximum time in seconds for graceful shutdown.</summary>
|
|
public int ShutdownTimeoutSeconds { get; init; } = 10;
|
|
|
|
/// <summary>The interval in seconds for worker heartbeats.</summary>
|
|
public int HeartbeatIntervalSeconds { get; init; } = 5;
|
|
|
|
/// <summary>The grace period in seconds after a heartbeat before considering the worker unresponsive.</summary>
|
|
public int HeartbeatGraceSeconds { get; init; } = 15;
|
|
|
|
/// <summary>The maximum message size in bytes for IPC communication.</summary>
|
|
public int MaxMessageBytes { get; init; } = 16 * 1024 * 1024;
|
|
}
|