Proto comments (comment-only, no wire change):
- mxaccess_worker.proto GatewayHello.max_frame_bytes: every worker->gateway frame
must serialize within the negotiated max; reply builders truncate (IPC-23).
- mxaccess_gateway.proto DrainEventsReply: count-cap + byte-cap, drain-until-empty
caller contract (IPC-23).
- mxaccess_gateway.proto ReplayGap.oldest_available_sequence: empty-ring value is
highest-observed+1, oldest-1 resume formula stays valid (GWC-25 deferred amendment).
Regen wave: Contracts/Generated (C# XML doc), rust vendored protos (byte-copy),
Go bindings (worker binding was genuinely stale - lacked MaxFrameBytes entirely),
Python worker _pb2 (real descriptor delta), Java aggregates (javadoc, zero
protobuf-version churn under the pinned toolchain), client descriptor set.
IPC-24: pinned Java toolchain regenerates with no gencode-version churn, so the
unconditional churn-revert step in ci.yml is a fossil - deleted it; git diff is
now a true message-level drift gate for the single-file Java aggregates.
IPC-25: pin protoc-gen-go v1.36.11 / protoc-gen-go-grpc 1.6.2 in the Go generate
script (+ fix a latent pwsh-7 parse bug); add Check 4 to check-codegen.ps1
(regenerate Go+Python bindings, fail on diff, tool-missing fails not skips); add
the pinned-generator installs to the portable CI job.
IPC-32: relabel check-codegen banners 1/4..4/4 (folded into the Check 4 edit).
Docs: ClientProtoGeneration.md, Contracts.md, GatewayTesting.md, build.gradle
checkGeneratedClean caveat. Tracking: IPC-23/24/25/32 -> Done, GWC-25 proto note
resolved, change-log 2026-08-07.
Flip the four findings to Done in the 2026-07-12 tracking registers
(Gateway core + Testing) and in the per-domain registers of
10-gateway-core.md and 60-testing-docs-gaps.md; append the 2026-08-07
change-log row recording what shipped, the pre-fix red for GWC-28, and
the TST-28 mutation check.
An empty replay ring reported oldest_available_sequence = 0 even when gap was
true. Clients follow the documented after_worker_sequence = oldest - 1 formula,
so an unsigned client computed ulong.MaxValue: the follow-up resume replayed
nothing, reported no gap, and the live filter dropped every subsequent event —
a silently dead stream in the headline detach-and-resume scenario, reachable on
default config once ReplayRetentionSeconds (300) age-evicts the ring.
GWC-25: SessionEventDistributor.RegisterWithReplay's empty-ring branch now
reports _highestSequenceSeen + 1 — the next sequence that can possibly be
delivered — when gap is true, so oldest - 1 lands exactly on the highest
observed sequence and the resume delivers everything newer. Still 0 when there
is no gap, where the field is meaningless and never emitted. Nothing is lost:
the evicted interval was unrecoverable either way, and the sentinel's job is to
say "re-snapshot".
CLI-35: the Python CLI fed every stream item into MessageToDict, which raised on
the ReplayGap dataclass and aborted the command after consuming the stream. A
new _event_row helper renders a gap as {"replayGap": {...}} — the same camelCase
shape the Rust CLI emits — and leaves proto events on the existing path.
CLI-36: the Go CLI formatted result.Event on every row, but the library
deliberately clears Event on a gap, so text mode printed
"0 MX_EVENT_FAMILY_UNSPECIFIED" and JSON mode an empty object, discarding the
resume cursors. The loop now branches on result.IsReplayGap() and renders the
typed row in both modes, counting it toward -limit like any other row. The JSON
row's cursors are typed by hand rather than marshalled with protojson: the
proto3 JSON mapping renders 64-bit integers as strings ("7") while the Rust and
Python CLIs emit numbers (7), so going through protojson would have made Go the
only canonical CLI with a different value type.
Docs in the same change: docs/Sessions.md documents the empty-ring sentinel
value and that oldest - 1 is the universal resume formula in both the retained
and fully-evicted cases; docs/CrossLanguageSmokeMatrix.md gains a per-CLI
gap-rendering table covering both client findings, and records exactly what is
and is not comparable across CLIs (same keys and numeric cursors for Rust/Go/
Python; quoted cursors for .NET/Java; differing key order, whitespace, and
container), so a matrix runner compares parsed values rather than raw bytes.
Tests, all written red first and each reproducing its defect verbatim:
- SessionEventDistributorTests: RegisterWithReplayReportsNextDeliverableSequence
WhenRingEmptiedByAge, ...WithRetentionDisabled, and
ResumeUsingSentinelFormulaAfterEmptyRingGapDeliversLiveEvents.
- GatewayEndToEndReconnectReplayTests.ReconnectAfterFullAgeEvictionResumesWith
SentinelFormula — fake-worker e2e resume walk on a fake clock; the fixture now
takes a retention window and a TimeProvider.
- clients/python test_stream_events_renders_replay_gap.
- clients/go TestRunStreamEventsPrintsReplayGap.
GWC-25's ReplayGap.oldest_available_sequence proto-comment amendment is
deliberately deferred to the later codegen wave (see the tracker change log): it
is comment-only but triggers the full five-client regen fan-out.
RunMonitorAsync issued SubscribeAlarms and the first reconcile before the
internal distributor subscriber was attached (via ISessionManager
.ReadAlarmEventsAsync). The pump has been running since MarkReady started the
dashboard mirror and only fans to subscribers registered at fan-out time, so
every transition raised in that two-round-trip window bypassed the alarm feed —
and a missed Acknowledge was never repaired, because ApplyReconcile broadcast
presence deltas only.
- The monitor now takes the internal lease directly from its session BEFORE
SubscribeAlarms and drains it after the first reconcile; window transitions
buffer in the lease's bounded channel. Processing them after ApplyReconcile is
order-safe (ApplyTransition handles alarms the snapshot already placed).
- ISessionManager.ReadAlarmEventsAsync removed — zero remaining callers.
- ApplyReconcile broadcasts an Acknowledge feed transition when a both-present
alarm's state advanced to ActiveAcked. This is a feed-level repair on the
AlarmFeedMessage/StreamAlarms surface rebuilt from the worker's own snapshot,
not MxEvent emission, so the "never synthesize events" rule is untouched;
the reasoning is recorded on ApplyReconcile.
The alarm-monitor test fakes now hand the monitor a real Ready GatewaySession
with a dashboard mirror, which is what makes the window reproducible.
Docs: docs/Sessions.md and gateway.md alarm-monitor ordering notes.
Refs: archreview/2026-07-12/remediation/10-gateway-core.md GWC-26
The GWC-04 remediation decoupled the read loop from event backpressure by
staging events into an unbounded channel, so its TryWrite always succeeded and
the only overflow fault was a single timed WriteAsync exceeding
EventChannelFullModeTimeout. A consumer draining slower than the worker
produces — each individual write still completing inside the window — therefore
grew gateway memory without bound, without a fault, and without a metric: the
queue-depth gauge counted only the bounded consumer channel, so staged events
were invisible.
Bound _eventStaging at 2 x EventChannelCapacity (Wait, single reader/writer, no
synchronous continuations). A rejected staging TryWrite is the sustained
slow-drain signal and faults the client ProtocolViolation with
QueueOverflow("worker-event-staging"), guarded by IsTerminalState() so a
completed channel during shutdown stays a silent drop. SetFaulted is
non-blocking, so the read loop still never awaits behind events. The timed-write
fault is unchanged and still catches the full-stall case earlier.
Move the queue-depth increment from EnqueueWorkerEventAsync to StageWorkerEvent
so the single counter reports total undelivered events (staged + queued); the
decrement at consumer read was already correct. No new configuration key: the
bound is derived, and gateway-side buffering per session is now at most
3 x MxGateway:Events:QueueCapacity. Coordination with still-open GWC-21
(EventChannelFullModeTimeout configurability) remains open and was not blocked
on.
Tests: StagingChannelOverflowFaultsWorkerWithoutWaitingForFullModeTimeout (5-min
full-mode timeout so only the staging bound can fire; asserts an interleaved
command reply still completes) and WorkerEventQueueDepthGaugeCountsStagedEvents.
Docs updated in the same change: GatewayProcessDesign, MxAccessWorkerInstanceDesign,
GatewayConfiguration, Metrics. GWC-24 flipped to Done in both trackers.
Six-domain re-review at the P2 merge (4f5371f): all prior Done claims
verified (none false, 10 partial), 47 new findings (1 High, 14 Medium),
with per-finding design/implementation plans and a new tracking register.