Commit Graph

11 Commits

Author SHA1 Message Date
dohertj2 d6c2ca33f1 CI: stand up Gitea Actions (TST-03) + fix the defects it caught (#123)
ci / windows (push) Failing after 13m38s
ci / java (push) Successful in 2m4s
ci / portable (push) Successful in 9m18s
ci / live-mxaccess (push) Has been cancelled
Make the authored CI pipeline execute and go green on the co-located runner (portable + java), fix the five real latent defects the first real run surfaced (codegen-check null, stale rust proto, orphan-terminator Linux path, stale java worker codegen, py3.12 event loop), provision pwsh + Gradle for the self-hosted act image, and disable the Windows jobs (act host-mode broken). TST-03 -> Done.

https://claude.ai/code/session_01DMXXvNuPekkkrTEyPNxEkW
2026-07-10 05:11:01 -04:00
Joseph Doherty 32d6b48910 feat(gateway): decouple worker event enqueue from the read loop (GWC-04)
The read loop awaited EnqueueWorkerEventAsync inline, which blocks in the bounded
event channel's timed WriteAsync (up to EventChannelFullModeTimeout, default 5s)
when the channel is full with no/slow consumer. A WorkerCommandReply or heartbeat
queued behind an event frame was then stalled, so an in-flight InvokeAsync could
hit CommandTimeout even though the worker replied in time.

Mirror the existing outbound WriteLoopAsync: add an unbounded event staging
channel and a dedicated EventWriteLoopAsync. DispatchEnvelope is now fully
synchronous — the WorkerEvent branch hands the event off with a non-blocking
TryWrite and the read loop never awaits. The event write loop owns the timed
WriteAsync into the bounded channel and the sustained-overflow ProtocolViolation
fault (unchanged contract). Registered in WaitForBackgroundTasks + completed on
close/fault/dispose.

Test: reply arriving after events with a full, consumer-less event channel is
dispatched promptly (no CommandTimeout) — pipe-harness, verified on windev.
Docs: GatewayProcessDesign read/write/event-loop section.
2026-07-09 09:28:13 -04:00
Joseph Doherty c8b3a2281a feat(ipc): negotiate worker frame max, add gRPC headroom, bound DrainEvents (IPC-02/03/04 gateway half)
Proto foundation + gateway-side of the size/backpressure pass:

- IPC-02: add GatewayHello.max_frame_bytes (regen Generated/); gateway sends
  its negotiated worker-frame max in the handshake so the worker can adopt it
  instead of a hard-coded default. Worker read-half lands separately.
- IPC-03: give the pipe frame max envelope-overhead headroom above the public
  gRPC cap (WorkerFrameProtocolOptions.EnvelopeOverheadReserveBytes = 64 KiB;
  default Worker.MaxMessageBytes bumped to 16 MiB + reserve), cross-validate the
  headroom at startup, and pre-check command envelope size in WorkerClient so an
  oversized command fails only that correlation (ResourceExhausted) instead of
  faulting the whole session.
- IPC-04: reject DrainEvents max_events above a public ceiling in the request
  validator (worker per-reply cap lands with the worker half).

Docs: GatewayConfiguration, WorkerFrameProtocol, gateway.md.
Tests: headroom validation, DrainEvents bound, oversized-command per-command
failure (pipe-harness, verified on windev).
2026-07-09 08:49:59 -04:00
Joseph Doherty 20392cf246 fix(archreview): gateway core P0 remediation (GWC-01/02/03, TST-02, TST-12)
Interlocking changes across the gateway server (shared GatewaySession.cs /
SessionManager.cs), committed together:

- GWC-01 (Critical): alarm monitor now attaches as an internal
  (non-counted) distributor subscriber instead of a second raw drain of the
  single worker event channel; WorkerClient._events -> SingleReader with a
  claimed-once guard so a future dual-consumer regression throws loudly.
- GWC-02 (High): faulted sessions are swept in CloseExpiredLeasesAsync
  (IsFaultedReapable + FaultedReason); new FaultedGraceSeconds (default 0).
- GWC-03 (High): configurable MaxSparseArrayLength (default 1_000_000)
  enforced before allocation.
- TST-02 (High, security): StreamEvents attach now enforces the opening key
  id -> PermissionDenied on owner mismatch.
- TST-12 (Medium): CLAUDE.md retention-defaults sentence corrected.

Verified: NonWindows build clean; targeted tests 135/135 on macOS, plus
WorkerClientTests 18/18 on the Windows host.
2026-07-09 05:51:57 -04:00
Joseph Doherty fca978de07 docs(src): add missing XML docs and strip tracking-ID comments
Sweep of 203 source files resolving CommentChecker findings: add
<summary>/<param>/<returns>/<inheritdoc> where missing, and remove
resolved task/issue tracking markers (Tests-NNN, Worker-NNN, Server-NNN,
Task N) from code comments. Comment/doc-only — no logic changes.
Server+Tests build clean under TreatWarningsAsErrors.
2026-07-07 14:09:49 -04:00
Joseph Doherty 44d676aede test(server): restore entireProcessTree kill assertion in WorkerProcessLauncherTests (Task 9 review) 2026-06-16 17:22:46 -04:00
Joseph Doherty 01bdb484de refactor(tests): consolidate FakeWorkerProcess onto TestSupport canonical 2026-06-16 17:14:03 -04:00
Joseph Doherty b298ca74be fix(java): picocli ParameterException for browse --depth; warn on --parent 0
Replaces the raw IllegalArgumentException thrown by GalaxyBrowseCommand for
--depth < 0 with a CommandLine.ParameterException so picocli surfaces a clean
single-line error instead of an unhandled stack trace. Adds an upper bound of
50 (matching the Python client) so --depth > 50 is also rejected cleanly.

Emits a stderr warning when --parent 0 is supplied explicitly, matching
Go/Rust client behaviour, because gobject id 0 is the server's root-walk
sentinel and passing it via --parent is almost always a mistake.

Adds three new tests: negative depth, depth > 50, and the --parent 0 warning path.
2026-06-15 11:08:07 -04:00
Joseph Doherty bb5139fec2 test(gateway): fake worker responds to control commands (A6)
Add RespondToControlCommandAsync to FakeWorkerHarness so scripted fake
workers can auto-reply to the five control command kinds (Ping,
GetSessionState, GetWorkerInfo, DrainEvents, ShutdownWorker) with canned
replies whose shapes match the real WorkerPipeSession helpers.

Add five unit tests in FakeWorkerHarnessTests covering each control
command kind through the WorkerClient→pipe roundtrip, and one gateway
E2E test (GatewayService_WithFakeWorker_ControlCommandsRoundtripThroughGateway)
that exercises Ping, GetWorkerInfo, and DrainEvents through the full
gRPC→SessionManager→WorkerClient→named-pipe path using a scripted
ControlCommandFakeWorkerProcessLauncher.
2026-06-15 10:56:56 -04:00
Joseph Doherty 615b487a77 docs+ui: backfill XML doc comments and finish dashboard layout pass
Adds missing <summary>/<param> XML docs across 99 server, worker, and test
files so CommentChecker reports zero issues (TreatWarningsAsErrors needs the
analyzer clean). Bundles in WIP dashboard work: NavSection extraction,
MainLayout/site.css/js styling alignment, and DashboardOptions/Auth tweaks.
2026-05-27 14:20:10 -04:00
Joseph Doherty dc9c0c950c rename: prefix gateway projects/namespaces with ZB.MOM.WW + sln→slnx
Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.

External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
  MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths

Also fixes two tests that were not rename-related but became visible
while validating the rename:

- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
  gateway service correctly maps to RpcException(Cancelled) per gRPC
  convention was being misclassified as a stream fault. Added a sibling
  catch on RpcException with StatusCode.Cancelled.

- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
  and made it accept either a .git marker OR a .sln/.slnx next to src/
  so the worker-exe walker works in non-git working copies.

clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.

Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
  Tests: 472/472 pass
  Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
  IntegrationTests: 18/18 pass

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 16:22:23 -04:00