Review found AlarmDispatcher.SnapshotActiveAlarms reading the snapshot and the
truncation verdict through two independent lock acquisitions, defended by a
comment claiming read-order made a race "widen only, never narrow". That claim
was false: a not-truncated -> truncated poll landing between the two reads pairs
a stale false with a capped snapshot, which is exactly the false all-clear the
feature exists to prevent. It was safe only because AlarmCommandHandler
STA-serializes consumer calls — an accident of the call graph, not an invariant.
Made the invariant structural instead of documented. IMxAccessAlarmConsumer now
exposes ONE accessor, `IReadOnlyList<MxAlarmSnapshotRecord> SnapshotActiveAlarms(
out bool truncated)`, which implementations must satisfy from a single
acquisition of the lock guarding the retained snapshot — mirroring the write
side, where FoldFetch already updates snapshot and verdict together. The
separate LastSnapshotTruncated property is gone from every layer, so there is no
second read left to pair badly. `out` over a result struct follows the file's
established idiom (FoldFetch, ParseSnapshotXml).
The same threading applies one level up: IAlarmCommandHandler.QueryActive now
carries `out bool snapshotTruncated`, so MxAccessCommandExecutor stamps the reply
payload from the value the records were stamped with rather than reading the
state a second time.
Direct tests for the three hops that were only covered end-to-end:
- AlarmDispatcherTests: truncated consumer snapshot stamps FromTruncatedSnapshot
on every mapped record, with a complete-snapshot control, plus an assertion
that the independent per-record Degraded flag is not dragged along.
- AlarmCommandHandlerTests: the verdict delegates through the dispatcher
(Theory over both values), and survives a prefix filter that removes every
record — the case the per-record flag cannot cover.
- AlarmCommandExecutorTests: the reply payload's SnapshotTruncated comes from the
handler (Theory over both values), including the zero-record case.
The WnWrapAlarmConsumer truncation tests now assert through
SnapshotActiveAlarms(out ...) rather than an internal field, because the pairing
is the contract.
Also: GatewayAlarmMonitor's _snapshotTruncated comment now says "as of the last
full reconcile" rather than implying it tracks the current _alarms contents,
which live transitions keep moving via ApplyTransition between passes.
Detection heuristic still untouched (fetchedRecordCount >= maxAlarmsPerFetch);
no @COUNT parsing, per docs/AlarmProbeFindings.md. Still additive gateway
metadata about our fetch mechanics, not MXAccess behavior — not a parity
deviation, and no event is synthesized.
Gateway: NonWindows.slnx builds clean (0 warnings); ~Alarm filter 107/107 pass.
Worker + Worker.Tests are windev-gated; the signature change was reviewed by
inspection across all 7 IMxAccessAlarmConsumer implementers, all 3
IAlarmCommandHandler implementers, and every call site.
The truncation-cliff fix made alarm transitions truncation-safe but silent:
when GetXmlCurrentAlarms2 returns exactly maxAlmCnt records the worker
suppresses absence-implies-Clear inference and says so only in a rate-limited
stderr warning. No client and no operator could tell a complete active set
from a capped one.
Two additive proto3 booleans carry the verdict out:
- QueryActiveAlarmsReplyPayload.snapshot_truncated = 2 (worker IPC reply)
- ActiveAlarmSnapshot.from_truncated_snapshot = 16 (per record)
The per-record field is not an aesthetic choice. QueryActiveAlarms returns a
bare `stream ActiveAlarmSnapshot` with no envelope, header, or trailer, so a
per-record boolean is the only carrier that stays wire-compatible; an envelope
message would change every existing client's stream element type. The reply
payload states it too because a prefix filter can leave zero records and a
truncated fetch with nothing to report still has to say so. The flag means
"this set may be incomplete", never "this record is unreliable" — it is
independent of the subtag-fallback `degraded` field.
Detection is deliberately UNCHANGED: IsTruncatedFetch remains
`fetchedRecordCount >= maxAlarmsPerFetch`. The live probe (docs/AlarmProbeFindings.md,
ce5d8ae) could not verify whether ALARM_RECORDS/@COUNT reports the total active
count or only the records in the reply, so @COUNT is not parsed for detection;
switching to it stays blocked on probe evidence. The probe's comment
annotations in WnWrapAlarmConsumer.cs are preserved.
Reset semantics: not latched. WnWrapAlarmConsumer.FoldFetch replaces the
verdict on every poll under the same lock as the snapshot merge, so the first
sub-cap fetch clears it; GatewayAlarmMonitor.ClearCache drops it with the cache
generation it describes. A caveat that never turns off is one operators learn
to ignore.
Flow: WnWrapAlarmConsumer.LastSnapshotTruncated -> AlarmDispatcher (stamps every
record) / IAlarmCommandHandler (payload) -> MxAccessCommandExecutor reply ->
GatewayAlarmMonitor._snapshotTruncated -> IGatewayAlarmService.SnapshotTruncated
-> DashboardAlarmQueryResult -> AlarmsPage warning banner (render-side only; the
poll loop and DisposeAsync drain are untouched). The public QueryActiveAlarms
RPC forwards worker snapshots unmodified, so the per-record flag needed no
mapper change — a test pins that.
Parity: this describes OUR fetch mechanics — additive gateway metadata — not
MXAccess provider behavior. No event is synthesized and no MXAccess-observable
semantics change, so it is not a parity deviation.
Tests: worker LastSnapshotTruncated set/reset/consecutive-burst (windev-run);
gateway end-to-end truncated reply -> monitor -> public stream, with the
complete-reply control as the load-bearing assertion; AlarmsPage banner
present/absent. Docs: gateway.md alarm surface, docs/DesignDecisions.md entry.
WriteAsync enqueued its frame and then contended unconditionally for the write
lock, so a caller that lost the race stayed in WaitAsync until the winning
drainer released — even though that winner writes, flushes, and completes the
loser's control frame at the control-to-event class boundary, part-way through
its pass. The boundary flush made the delivery point honest; the awaited task
was still charged for the whole event backlog it had just been flushed ahead of.
WriteAsync now awaits its own frame's completion racing the lock acquisition.
Completion first: the caller returns at its frame's delivery point and the
outstanding acquisition is detached, not dropped — a continuation drains
whatever is queued and releases, so the lock is never acquired and silently
held and a frame enqueued between the previous drainer's last dequeue and its
release is still written. Lock first: drain as before. Cancellation keeps the
WRK-22 tombstone semantics exactly, and a wait cancelled after the caller has
already detached releases nothing (SemaphoreSlim hands no count to a wait it
cancels), so no count leaks and no queued frame is stranded. A token that fires
after the frame's completion won the race changes nothing — the frame was
delivered. WriteBatchAsync deliberately keeps the plain wait-then-drain shape:
its last completion resolves at the end-of-pass flush anyway.
Three tests: the latency win (a control caller returning while the winning
WriteBatchAsync event burst is demonstrably still blocked mid-pass), a
mixed-priority concurrency soak pinning exactly-once writes and a single
drainer, and the cancel-after-detach corner (a wrongly released count would
surface as the drainer's own Release throwing SemaphoreFullException).
edited on macOS, windev verification pending (plan Task 11). Verified here by
compiling and running WorkerFrameWriter plus the writer suite against net10.0
in a scratch harness: 31/31 pass, and the two behaviour-pinning tests fail
against the pre-change parked implementation.
The two-class writer already got control bytes out ahead of a queued event
backlog, but a frame counts as delivered only once flushed, and the drain
deferred its single FlushAsync — and every TrySetResult — to the end of the
pass. A heartbeat, command reply, fault, or shutdown ack was therefore written
first and completed last, behind up to a full 128-frame event batch.
The drain now records each frame's priority class on PendingFrame and flushes
at every control-to-event boundary, completing and clearing the written set
there. Cost stays bounded: a pure-event pass still pays exactly one flush, a
run of control frames still pays one for the run, and only a pass that mixes
both classes pays a second — never one flush per control frame, the
syscall-per-heartbeat cost WRK-12 removed.
A boundary flush that itself fails is a new failure window and is handled like
the end-of-pass flush failure, additionally failing the event frame the drain
had already claimed off its queue and every frame still queued. Frames a
boundary flush completed leave the written set, so a later failure in the same
pass can no longer reach back and fail an already-delivered control frame.
The awaited task of a caller that lost the write-lock race is still bounded by
the winning drainer's pass — that enqueue-then-contend parking is unchanged and
now documented on WriteAsync and in docs/WorkerFrameProtocol.md.
MxAccessValueCache.Set deep-copied the Value (recursive for an MxArray), the
SourceTimestamp, and the Statuses RepeatedField (container plus every
MxStatusProxy) on every OnDataChange. The aliasing audit found all three
removable: the sink enqueues the event first — which stamps
WorkerSequence/WorkerTimestamp inside the queue lock — and only then runs the
postPublish hook that reaches Set, so the event is write-once by then and the
queue's ownership invariant forbids later mutation. The producer never reuses
instances (fresh MxEvent per mapper call, fresh MxValue per convert), and the
alias already existed on the read side: MxAccessSession.SucceededRead puts the
cache's own Value/SourceTimestamp/status references on every BulkReadResult,
which the worker only serializes onto the IPC pipe.
Set and CachedValue now carry the ownership contract: the cache holds borrowed
references into an enqueued, write-once MxEvent; consumers may read and
serialize, never mutate. Mutation would corrupt the still-queued event AND
invalidate QueuedEvent.Size — the enqueue-time memoized serialized size the
byte-budgeted Drain charges — so a grown message could overshoot the negotiated
frame max and fault the session with MessageTooLarge. MxAccessEventQueue's
class remark, which claimed the cache keeps an independent snapshot, is
corrected to point at the borrow.
MxAccessWriteCompletionCache.Record keeps its parallel statuses.Clone()
deliberately, with a cross-reference explaining why: it takes a bare
RepeatedField whose provenance its signature cannot constrain, and it is on the
command-rate write path, not the streaming hot path.
Tests: Set_StoresIndependentSnapshot_UnaffectedByLaterEventMutation codified
the invariant being reversed, so it is replaced by
Set_BorrowsTheEventsOwnInstances_ByOwnershipContract (Assert.Same on Value,
SourceTimestamp, and the status row). Adds the missing cached-read-path test to
MxAccessCommandExecutorTests — nothing in the worker exercised was_cached ==
true end to end — asserting the cache hit, reference identity out to the
BulkReadResult, and that no COM call is made for the read.
Not built or tested here: these are net48/x86 worker files that cannot compile
on the macOS tree. Verification is deferred to the windev gate.
The worker-side half of the review tail. Tests and comments only — nothing here
changes worker behavior, and none of it compiles on the macOS tree (net48/x86),
so it was reviewed line by line against the already-windev-validated files.
- MxAccessHandleRegistryTests gains the multi-candidate case behind
MxAccessSession.TryGetCachedReadFor's fall-through: one tag under two item
handles, the lower registered-but-unadvised and the higher advised. Asserted
at the registry rather than the session because the session's read path needs
a live MXAccess COM instance; what the registry owes the scan is the stable
ascending candidate order and a per-item-handle (not per-tag) advice index,
and both are pinned here along with the fall-through contract in prose.
- A single adversarial lifecycle test — register, advise, re-register the same
item handle under a new tag, unadvise, unregister the server — asserting every
index agrees after each step. The individual transitions were already covered;
what was not was that they compose, and a stale entry in any one index
resurrects a handle MXAccess has already retired.
- StaWaitHelperTests.WaitForSignalOrMessages_PreSignalledHandle_ReturnsImmediately
drains pending messages first, like the other two wait tests. Without it a
stale message can end the wait instead of the handle, failing the
signal-consumed post-condition for an unrelated reason.
- GatewayTesting.md records the two findings from the Task 24 windev gate:
SecretsStorePathGuardTests.CreateBuilder_AcceptsSecretsStoreOutsideContentRoot_AndCreatesIt
fails deterministically on Windows on main too (SQLite pooling holds secrets.db
open across the cleanup's recursive delete; pre-existing, tracked separately),
and the StaWaitHelper timing tests' flake signature on a loaded box is a
message wake — the helper working as designed — not a broken wait.
The windev full-suite wedge — every test reported, then the x64 testhost sitting
at ~0 CPU forever while `dotnet test` never returns — was one test blocked on a
pipe write, not a leaked thread or an undisposed fixture.
`dotnet-stack report` on the wedged host showed no thread running test code:
xUnit's RunTestsInAssembly was parked on WaitHandle.WaitOne() waiting for the
assembly-finished event, so the wait lived in a suspended async state machine.
`dotnet-dump analyze -c dumpasync` named the frame — WorkerClientTests
.StagingChannelOverflowFaultsWorkerWithoutWaitingForFullModeTimeout awaiting
WorkerFrameWriter.WriteAsync on a 63-byte frame, with <extra>5__15 = 6, i.e. the
seventh of the twelve events the test pushes past the client's staging bound.
That test faults the worker client on purpose, and a faulted client stops its
read loop by design. The test-side pipe came from the NamedPipeServerStream
overload without buffer arguments, which passes inBufferSize: 0 / outBufferSize: 0
to CreateNamedPipe; on Windows that reserves no buffer at all, so a write
completes only once the peer reads it. Measured on windev, that pipe absorbed
0 bytes against a non-reading peer where the same pipe declared with 64 KiB
buffers absorbed 65 520. On macOS and Linux .NET backs named pipes with Unix
domain sockets whose socket buffer swallows the writes regardless, which is why
the identical test never hung there and the bug read as environmental.
Test-owned server pipes now go through TestSupport/TestNamedPipe.CreateServer in
both test projects, declaring explicit 64 KiB buffers so those tests exercise the
gateway's own staging/queue backpressure rather than the OS pipe's flow control.
Separately, every fake-worker write in WorkerClientTests now goes through
PipePair.WriteAsync, bounded by the class's five-second TestTimeout. That is
where the severity came from: a test method that never returns keeps xUnit from
raising ITestAssemblyFinished, so one unbounded await cost the whole suite its
result. A blocked write is now a named test failure instead of a silent wedge.
The fix also retires a wrong belief the wedge had created. windev reported 855
where macOS reported 879, and that gap was recorded in GatewayTesting.md as
Unix-gated test cases; it was really the results lost when the wedged host was
torn down. The same clone now reports 879 passed, matching macOS exactly.
Product code is unaffected. SessionWorkerClientFactory.CreatePipe keeps the
unbuffered declaration deliberately: both ends run continuous read loops and every
gateway write is bounded by the worker client's _stopCts, so a stalled peer
cancels the write rather than blocking on it.
Verified on windev at this SHA: gateway suite x64 three times (879 passed,
exit 0, no surviving testhost each time) and Worker.Tests x86 twice (400 passed,
11 skipped, exit 0, clean), plus the macOS gateway suite once (879 passed).
Docs: GatewayTesting.md replaces the --blame-hang workaround section with the
root cause and corrects the baseline to 879, CLAUDE.md's Source Update Workflow
no longer tells readers the windev suite wedges, and ToolchainLinks.md records
dotnet-stack and dotnet-dump as installed on windev.
Root cause. The test sampled its flush baseline after a bare `Task.Delay(100)`
and then charged every later flush to the 128-event burst. Two facts make that
window unsound:
1. `RunHeartbeatLoopAsync` sends its first beat *immediately* on entering the
message loop — the far-off `HeartbeatInterval` only spaces later beats — so
the pre-burst frames are WorkerHello, WorkerReady, and a heartbeat, not the
two the test's comment assumed.
2. `WorkerFrameWriter.DrainQueuedFramesAsync` flushes *after* writing a drained
batch, so the bytes reach the pipe before the flush runs. Reading a frame off
the gateway side is therefore no evidence that its flush has been counted,
and no sleep makes it evidence.
Under load on the shared windows-x86 runner the first heartbeat's flush was
scheduled after the 100 ms sample, so it landed inside the measured window and
the assertion saw two flushes for the burst — exactly the observed
`Expected: 1 / Actual: 2` (Gitea run 675, job 2558, and the same failure since
a346d51). Nothing about the coalescing behavior was wrong; only the test's
timing assumption.
Fix. Replace the sleep with explicit synchronization, no widened timeouts.
`FlushCountingPassthroughStream` now records the flush *shape* — the number of
stream writes coalesced into each flush — and exposes
`WaitForAllWritesFlushedAsync`, a TaskCompletionSource signal released when the
next flush drains the pending writes. The test reads the first heartbeat (the
last pre-burst frame), waits for its flush, and only then samples the baseline;
after the burst it takes the same edge before asserting. The assertion is also
sharpened from a bare count to the shape: exactly one flush beyond the baseline
*and* that flush carried all 128 event frames, so a split batch fails even if
the reader observes it mid-split.
docs/WorkerFrameProtocol.md notes the peer-visible ordering the fix turns on:
frames reach the pipe before the flush that follows them, so an observer of the
flush must wait for it rather than infer it from frames arriving.
A WriteAsync/WriteBatchAsync caller cancelled after the draining lock-holder
claimed its frame unwinds without awaiting that frame's completion; the same
holds for a frame already faulted by a concurrent FailAllQueued, where
TrySetCanceled loses. A later wire-write failure then lands TrySetException on
a task with no awaiter and surfaces as TaskScheduler.UnobservedTaskException.
The tombstone helpers now attach a fault-observing continuation to every frame
in the cancelled call (a cancelled task never fires OnlyOnFaulted, so
unconditional attach is safe), outside _gate because an already-faulted task
runs the continuation inline.
NEXT-05 is resolved as a documented decision, not a code change: tombstoned
entries keep their lazy DequeueNext purge — any subsequent write drains both
queues to empty and the heartbeat loop bounds residency to one interval, while
eager Queue<T> rebuilds under _gate would add ordering-invariant surface for
no gain. Rationale recorded in docs/WorkerFrameProtocol.md alongside the
WRK-22 residual-window contract.
New regression test drives the exact abandonment: gated stream holds writer A
mid-write, the queued event frame is claimed and blocked mid-write, its caller
is cancelled, the write then faults with a marker exception, and the test
asserts the marker never reaches UnobservedTaskException after a forced GC.
net48 x86 build/test runs on windev with the rest of this batch.
OtOpcUa's dominant FreeAccess write path goes out as MX_COMMAND_KIND_WRITE,
not WriteSecured — the original 06/S-1 brief mis-scoped the correlation, so
a refused plain write was invisible on the unary reply (verified live on
windev 2026-08-09). ExecuteWrite/ExecuteWrite2 now use the same pre-call
version baseline + bounded pump-wait as the secured kinds. Bulk writes stay
fire-and-forget.
WRK-22/IPC-26: tombstone a WriteAsync/WriteBatchAsync cancelled while
waiting for the write lock (PendingFrame.Claimed under _gate; DequeueNext
skips cancelled, claims the frame it returns) so a cancelled write never
reaches the wire unless already claimed mid-write (documented residual).
WRK-25: add WriteBatchAsync; RunEventDrainLoopAsync submits the drained
event batch through it, so a burst of N events costs one flush not N.
IPC-30 oversized-event structured fault preserved via FindOversizedEvent.
WRK-24: reject a below-1024 negotiated frame maximum at the handshake
(MinNegotiableFrameBytes, matching GatewayOptionsValidator floor).
WRK-27: alarm poll advertises StaCallInProgress on the heartbeat snapshot
so the watchdog suppresses to the ceiling, not the grace.
Docs (WorkerFrameProtocol.md, MxAccessWorkerInstanceDesign.md) and the
2026-07-12 remediation registers/change-log updated in the same commit.
Review follow-ups on the WRK-21 cluster.
1. ResolveDrainReplyByteBudget was a step function, not a floor: just above the
64 KiB reserve the budget collapsed to a few bytes (at the validator-permitted
floor MaxMessageBytes = 1024 + 64 KiB it was exactly 1024), too small to move a
byte-heavy event, so DrainEvents truncated on every call and the drain-until-
empty loop never terminated. It now takes the max of (frameMax - reserve) and
frameMax/2, so the budget is monotonic and never below half the frame max. New
test DrainEvents_AtValidatorFloorFrameMax_MakesProgressAndTerminates drives a
byte-heavy queue at the exact validator floor and asserts it drains to empty
with no head ever reported oversized.
2. The reply-too-large fallback write is now itself size-guarded
(WriteReplyTooLargeFallbackAsync, used by both the control and STA reply seams):
at a pathologically tiny negotiated max below the gateway's floor the fallback
could also throw MessageTooLarge and — uncaught — kill the session, defeating the
"no diagnostics command is session-fatal" invariant. It now log-and-swallows;
comment notes WRK-24 adds the negotiated-max lower bound that makes it unreachable.
3. Corrected the RepeatedFieldOverheadBytes doc comments: WorkerEvent.CalculateSize()
already includes the event's tag and length prefix (the same shape the reply's
repeated events field packs), so the 8 bytes is pure slack over an already-
conservative estimate, not compensation for a missing wrapper.
Change-log row for 2026-08-07: what landed for WRK-21/WRK-28/WRK-23/IPC-30, why
IPC-23 stays In progress (proto-comment/doc wave pending), and the verification
evidence — macOS NonWindows build + validator tests, and the documented windev
path (scripts/ci/windev-worker-ci.ps1 -Mode test) at a256560: x86 Worker build
clean, Worker.Tests 367 passed / 0 failed / 11 skipped.
PipePair runs both ends of a duplex pipe in one process with blocking
FlushFileBuffers under every frame write, so it wedges after roughly 85 large
round trips. Drain the full 10,000 byte-heavy events to empty at the queue layer,
where the no-loss property actually lives, and keep the pipe walk at 1,000 events
(29 replies) so it still proves the split end to end. Also give the truncation
test's budget slack: item handle 0 is a proto3 default and is not serialized, so
the probe measurement is a lower bound on the fixture's per-event cost.
PipePair has no continuous read pump — the test thread drains the pipe only
while it sits in ReadUntilAsync — so multi-megabyte DrainEvents frames
interleaved with the heartbeat loop wedge both ends inside FlushFileBuffers,
each waiting for the other to read. Negotiate a 128 KiB frame maximum instead:
the 10,000 byte-heavy events still overflow it many times over, so every
assertion (bounded reply, reported truncation, no event loss across repeated
drains, surviving session) is unchanged.
WRK-21 — DrainEvents was bounded by event count only, so a byte-heavy queue
(large string/array MxValues) built a reply above the negotiated frame maximum:
the writer rejected the frame, the exception unwound the session, and the events
already dequeued were destroyed. The drain is now byte-budgeted inside the queue
lock, so an event is dequeued only once it is known to fit and one that does not
stays at the head. Truncation is reported through the reply's existing
DiagnosticMessage (no contract change); callers drain until an empty reply. Both
reply-write seams — the control-command path and ProcessCommandAsync — now catch
MessageTooLarge and answer the correlation with an InvalidRequest reply instead
of unwinding or faulting the session. Satisfies IPC-23 R1-R3.
WRK-28 — the 10,000 drain ceiling moves to GatewayContractInfo
.MaxDrainEventsPerCommand, referenced by both the gateway request validator and
the worker clamp, replacing a comment-only sync contract. C# const only; no
.proto change.
WRK-23 — WorkerFrameWriter now peek-stamps, validates, then commits the sequence
counter immediately before the stream write, so a per-frame rejection leaves no
phantom gap on the wire.
IPC-30 — an oversized event frame stays session-fatal (it is undeliverable end to
end and neither dropping nor synthesizing a replacement is allowed), but the
death is structured: the event's identity and sizes are logged (never its value),
a WorkerFault with category PROTOCOL_VIOLATION and command method EventDrain is
written, then the session exits as before.
Docs updated in the same change: MxAccessWorkerInstanceDesign.md (drain byte cap,
truncation contract, oversized-head behavior, oversized-event policy, no control
reply is session-fatal on size), WorkerFrameProtocol.md (reply pre-sizing,
non-fatal reply-size rule, oversized-event policy, rejected frames do not consume
sequence numbers), gateway.md (DrainEvents two-axis bound).
Resolve all CommentChecker findings across the gateway server, worker, tests,
and .NET client (314 -> 0 real issues): add missing <returns>/<summary>/<param>
on public and test members, convert Stream/interface overrides to <inheritdoc/>,
and remove internal task/issue tracking IDs (SEC-*, IPC-*, WRK-*, GWC-*, TST-*,
Client.Dotnet-*) from shipped code documentation while preserving the design
rationale prose. Shipped comments should not carry internal bookkeeping, and
complete XML docs keep the analyzer/TreatWarningsAsErrors gate and generated API
docs clean. The 6 remaining flags are heuristic false positives (MD5, UTC-4,
capacity-1, near-1601) left intact so real documentation is not corrupted.
Claude-Session: https://claude.ai/code/session_01DMXXvNuPekkkrTEyPNxEkW
WRK-06: MxStatusProxyConverter caches the four resolved FieldInfo per status
type in a static ConcurrentDictionary (the GetField metadata scan ran 4x per
status per event on the STA path). GetValue+Convert.ToInt32 still run per event
(late-bound RCW). Exceptions byte-identical: missing-field message unchanged
(ResolveField, not cached on throw via GetOrAdd); null-value message unchanged.
WRK-11: MxAccessEventQueue.Enqueue takes ownership of the passed MxEvent -
stamps WorkerSequence/WorkerTimestamp on it in place and enqueues it, no
Clone(). Audited all 3 callers (base/alarm event sinks, provider-mode handler):
each builds a fresh event per Enqueue, none reuse it. MxAccessValueCache.Set now
deep-copies its retained Value/SourceTimestamp/Statuses so the cache snapshot
never aliases the queue-owned (later serialized) event. Net: alarm/other events
clone nothing (was full clone); data-change clones payload-only.
WRK-12: WorkerFrameWriter coalesces the flush across a drained batch - each
frame is written but not flushed individually; one FlushAsync after the batch,
then all written frames complete. Preserves the written+flushed completion
contract; a burst of N events costs 1 flush, not N. On write failure the whole
in-flight batch + queue fail so no caller hangs.
IPC-15 (doc): the multi-event WorkerEnvelope body remains unimplemented (wire
still carries one event per worker_event frame); gateway.md Performance section
now distinguishes the shipped flush-coalescing from that deferred proto change.
net48-safe (no init/records; readonly struct cache entry). Worker builds x86
only - verification on windev. Tests added: converter cache-reuse, queue
ownership-transfer, value-cache snapshot independence, writer batch-flush-once.
Claude-Session: https://claude.ai/code/session_01DMXXvNuPekkkrTEyPNxEkW
Worker half of the Wave 3 size/backpressure + write-ordering pass:
- IPC-02: the worker adopts GatewayHello.max_frame_bytes during the handshake
(WorkerFrameProtocolOptions.AdoptNegotiatedMaxMessageBytes) instead of a
hard-coded default; 0 keeps the default, a value above a 256 MiB ceiling is
rejected. Reader and writer share the options instance, applied before the
message loop.
- IPC-04: DrainEvents caps each reply at MaxDrainEventsPerReply (10_000) and
treats max_events = 0 as that cap rather than 'drain the entire queue', so one
diagnostic drain cannot pack a session-killing reply frame.
- WRK-04: WorkerFrameWriter stamps the envelope Sequence at the actual point of
writing (under the write lock) instead of at envelope creation, so the on-wire
order and the stamped sequence always agree under concurrent producers.
- WRK-07: the writer is now a cooperative priority scheduler — callers enqueue at
Control or Event priority and the draining lock-holder writes all control
frames before any event frame, so replies/faults/heartbeats jump ahead of an
event backlog. Per-frame validation/size rejections fail only that frame; a
stream write failure fails all queued frames.
Tests: monotonic gap-free sequence under concurrency, control-before-event
priority (gated stream), negotiated-max adoption, DrainEvents zero-bound.
Worker builds x86 only — verified on windev.
A long legitimate ReadBulk pumped Windows messages without refreshing
LastStaActivityUtc, so the watchdog false-positived StaHung past
HeartbeatStuckCeiling and then silently dropped every reply. PumpPendingMessages()
now calls MarkActivity() after pumping; a genuinely stuck STA (no pumping)
still accrues staleness and faults correctly. No MXAccess parity change.
archreview: WRK-01 (P0). Verified on the Windows host (x86): worker builds
clean, StaRuntimeTests + WorkerPipeSessionTests 33/33 pass.
Client.Java-040..048, Worker.Tests-034/035/036. Edits applied on the Mac,
which has no JRE and cannot build the x86+MXAccess worker tests; findings are
marked In Progress pending gradle + x86 build verification on windev. Do not
mark Resolved until verified there.
Wire up the previously-unimplemented Suspend, Activate, AuthenticateUser,
ArchestrAUserToId, AddBufferedItem, and SetBufferedUpdateInterval command
kinds in MxAccessCommandExecutor. These are real COM calls and run on the
STA via the executor.
- IMxAccessServer gains the 6 methods; MxAccessComServer routes them to the
right interface version (Suspend/Activate -> ILMXProxyServer4 out MxStatus,
AuthenticateUser -> base ILMXProxyServer, ArchestrAUserToId ->
ILMXProxyServer2, AddBufferedItem/SetBufferedUpdateInterval ->
ILMXProxyServer5).
- Suspend/Activate surface the native MxStatus, converted to MxStatusProxy
via the existing MxStatusProxyConverter.
- AuthenticateUser hands the credential straight to MXAccess and never logs
it; native HResult failures propagate via the dispatcher.
- MxAccessSession gains matching pass-throughs; AddBufferedItem registers
the item handle in the handle registry.
- Unit tests (fake IMxAccessServer / fake COM object) cover each arm plus a
password-non-leak assertion; existing IMxAccessServer fakes updated.
No proto changes (all request/reply messages already exist).
Ping is now intercepted as a worker control command and answered on the
message-loop thread, so the dispatch/heartbeat/shutdown-race tests must use a
genuine STA-dispatched command kind to keep exercising DispatchAsync.
Answer the five worker control/lifecycle commands at the WorkerPipeSession
message-loop layer instead of the STA-bound MxAccessCommandExecutor. These
replies are built from process-level state (worker pid, assembly version,
worker lifecycle, the runtime session's event queue) the executor cannot see,
and ShutdownWorker must emit its OK reply before the graceful shutdown joins
the STA thread - dispatching it onto the STA would deadlock.
- Ping: OK reply, echoes message into diagnostic_message.
- GetSessionState: maps WorkerState to proto SessionState.
- GetWorkerInfo: pid, worker version, MXAccess ProgID/CLSID.
- DrainEvents: drains the runtime event queue into DrainEventsReply.
- ShutdownWorker: OK reply, then graceful shutdown, then stops the loop.
Tests added in WorkerPipeSessionTests; FakeRuntimeSession gains a
batch-size drain suppressor so DrainEvents does not race the background
drain loop.
C6a: the rig's TestAlarm attributes are object-driven; a flip script OR a manual
operator/IDE toggle drives them (confirmed live 2026-06-14). Update the how-to-run
comments and Skip reason accordingly.
B3: track advised handles separately from added handles so Dispose only UnAdvises
items that were actually advised — a write-only subtag (e.g. ack-comment added by
Write, never advised) is removed but not unadvised. Add Dispose tests covering the
advised/write-only split, full removal, single Unregister, and double-dispose
idempotency.