Answer the five worker control/lifecycle commands at the WorkerPipeSession
message-loop layer instead of the STA-bound MxAccessCommandExecutor. These
replies are built from process-level state (worker pid, assembly version,
worker lifecycle, the runtime session's event queue) the executor cannot see,
and ShutdownWorker must emit its OK reply before the graceful shutdown joins
the STA thread - dispatching it onto the STA would deadlock.
- Ping: OK reply, echoes message into diagnostic_message.
- GetSessionState: maps WorkerState to proto SessionState.
- GetWorkerInfo: pid, worker version, MXAccess ProgID/CLSID.
- DrainEvents: drains the runtime event queue into DrainEventsReply.
- ShutdownWorker: OK reply, then graceful shutdown, then stops the loop.
Tests added in WorkerPipeSessionTests; FakeRuntimeSession gains a
batch-size drain suppressor so DrainEvents does not race the background
drain loop.
Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.
External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths
Also fixes two tests that were not rename-related but became visible
while validating the rename:
- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
gateway service correctly maps to RpcException(Cancelled) per gRPC
convention was being misclassified as a stream fault. Added a sibling
catch on RpcException with StatusCode.Cancelled.
- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
and made it accept either a .git marker OR a .sln/.slnx next to src/
so the worker-exe walker works in non-git working copies.
clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.
Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
Tests: 472/472 pass
Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
IntegrationTests: 18/18 pass
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>