Joseph Doherty 371bcb3f91 Resolve Worker.Tests-008..015 code-review findings
Worker.Tests-008: moved the misplaced WorkerLogRedactor test out of
VariantConverterTests into Bootstrap/WorkerLogRedactorTests.

Worker.Tests-009: renamed 46 snake_case alarm-test methods to PascalCase
Method_Scenario_Expectation.

Worker.Tests-010: replaced a weak Assert.Contains with an exact assertion
against the real diagnostic message and corrected the XML doc.

Worker.Tests-011: renamed and re-documented a cancellation test that
overstated what it proved.

Worker.Tests-012: added an oversized-frame (MessageTooLarge) test; renamed
the mislabeled zero-length-payload test.

Worker.Tests-013: removed the fixed-100ms ThrowIfCompletedAsync helper; the
caller now races runTask deterministically.

Worker.Tests-014: consolidated duplicated test fakes/helpers
(FakeRuntimeSession, NoopComApartmentInitializer, NoopEventSink, frame
helpers) into a shared TestSupport namespace.

Worker.Tests-015: added MxAccessEventQueue coverage for drain-all (maxEvents
0), empty-queue drain, and enqueue-after-fault.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-18 22:59:07 -04:00
Joseph Doherty a67a5a4857 fix(worker): wire alarm command handler and STA poll loop (Gap 1 + Gap 2)
Gap 1 — WorkerPipeSession now passes `eq => new AlarmCommandHandler(eq)` as
the alarmCommandHandlerFactory in all three places it constructs
MxAccessStaSession (two convenience constructors and InitializeMxAccessAsync).
Previously the parameterless MxAccessStaSession() set the factory to null,
so every SubscribeAlarms / AcknowledgeAlarm / QueryActiveAlarms command
returned "alarm consumer not configured" in a deployed worker.

  - Added internal `MxAccessStaSession(Func<MxAccessEventQueue, IAlarmCommandHandler>?)`
    constructor that builds all defaults but accepts a factory.
  - Added public `MxAccessStaSession(StaRuntime, factory, eventQueue, alarmFactory?)`
    4-arg overload to complete the constructor chain.

Gap 2 — WnWrapAlarmConsumer now disables its internal threadpool Timer
(pollIntervalMilliseconds=0 in the default constructor). MxAccessStaSession
starts a `RunAlarmPollLoopAsync` background task that sleeps off-STA then
calls `staRuntime.InvokeAsync(() => handler.PollOnce())` at 500ms intervals.
This satisfies the ThreadingModel=Apartment requirement of wwAlarmConsumerClass:
every GetXmlCurrentAlarms2 call now runs on the worker's STA.

  - Added `PollOnce()` to `IMxAccessAlarmConsumer`, `AlarmDispatcher`,
    `IAlarmCommandHandler`, and `AlarmCommandHandler`.
  - Poll loop cancelled and awaited before alarm handler disposal in both
    ShutdownGracefullyAsync and Dispose.

Tests: 4 new tests in MxAccessStaSessionTests verify that
  - SubscribeAlarms reaches the handler when the factory is wired (Gap 1)
  - SubscribeAlarms returns InvalidRequest without a factory (regression guard)
  - PollOnce is called on the STA thread within 3s (Gap 2)
  - The poll loop stops after Dispose (Gap 2 lifecycle)
All fake IMxAccessAlarmConsumer / IAlarmCommandHandler test implementations
updated with no-op PollOnce() to satisfy the new interface member.

Worker tests: 199 passed / 1 pre-existing failure / 4 skipped (was 195/1/4).
Server tests: 308 passed / 0 failures (unchanged).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-18 06:30:14 -04:00
Joseph Doherty 4e02927f01 A.3 (alarm-ack-by-name): public AcknowledgeAlarm now accepts Provider!Group.Tag references
Closes the gap where the public AcknowledgeAlarm RPC required canonical
GUIDs but OnAlarmTransitionEvent.AlarmFullReference is "Provider!Group.Tag".
Adds an AVEVA AlarmAckByName path that wraps wwAlarmConsumerClass.AlarmAckByName
so callers can ack with the natural reference.

Proto:
- New MxCommandKind.AcknowledgeAlarmByName (=29).
- New AcknowledgeAlarmByNameCommand(alarm_name, provider_name, group_name,
  comment, operator_user/node/domain/full_name) on MxCommand oneof.
- AcknowledgeAlarmReplyPayload (existing) carries the AVEVA native
  status; reused for the by-name path.

Worker:
- IMxAccessAlarmConsumer + WnWrapAlarmConsumer + AlarmDispatcher +
  AlarmCommandHandler all gain an AcknowledgeByName(name, provider,
  group, comment, operator-identity) overload that maps to
  wwAlarmConsumerClass.AlarmAckByName.
- MxAccessCommandExecutor: new switch arm routes
  MxCommandKind.AcknowledgeAlarmByName to the handler. Empty alarm_name
  yields InvalidRequest; handler exceptions surface as MxaccessFailure.

Gateway:
- WorkerAlarmRpcDispatcher.TryParseAlarmReference: parses
  "Provider!Group.Tag" with the convention that the FIRST '!' separates
  provider, the FIRST '.' after '!' separates group; tag may contain
  more dots.
- AcknowledgeAsync now branches: GUID input → AcknowledgeAlarm command
  (existing path); reference input → AcknowledgeAlarmByName command
  (new path); neither parses → InvalidRequest with a clear diagnostic.

Tests: 13 new unit tests cover each layer end-to-end:
- WorkerAlarmRpcDispatcher.TryParseAlarmReference (3 valid + 8 invalid
  forms) including the realistic 4-component "Galaxy!TestArea.
  TestMachine_001.TestAlarm001" reference.
- WorkerAlarmRpcDispatcher.AcknowledgeAsync routes references through
  AcknowledgeAlarmByName + propagates the full operator tuple.
- Executor switch arm carries the by-name tuple and rejects empty
  alarm_name.
- AlarmDispatcher.AcknowledgeByName forwards to consumer.
- Existing fakes extended for the new overload.

Counts: server 308/0, worker 195/3 skip / 1 pre-existing structure-fail
(untouched). Solution builds clean.

End-to-end alarms-over-gateway now serves the full lmxopcua flow:
client.AcknowledgeAlarm(reference="Galaxy!TestArea.TestMachine_001.TestAlarm001",
operator_user="alice") → gateway parses → IPC AcknowledgeAlarmByName →
worker AlarmAckByName → AVEVA history. The remaining piece for full
parity is a live dev-rig smoke test.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-01 11:17:15 -04:00
Joseph Doherty 82eb0ad569 A.3 (in-process slice): AlarmDispatcher wires consumer events onto event queue
Adds the in-process plumbing that connects WnWrapAlarmConsumer's
AlarmTransitionEmitted stream to the worker's MxAccessEventQueue via
MxAccessAlarmEventSink. With this change a transition raised by the
consumer lands as an OnAlarmTransitionEvent proto on the queue,
SessionId attached, ready for IPC dispatch.

Mapping: provider!group.tag → AlarmFullReference, tag → SourceObjectReference,
priority → severity, wnwrap STATE → AlarmConditionState (Active /
ActiveAcked / Inactive — wnwrap's ack-vs-unack-on-cleared distinction
collapses since OPC UA Part 9 doesn't model it). State delta drives
AlarmTransitionKind via the existing AlarmRecordTransitionMapper table.

Holding off on the proto IPC additions (SubscribeAlarms /
AcknowledgeAlarm / QueryActiveAlarms commands + WorkerAlarmRpcDispatcher)
for a follow-up — those touch every layer of the worker IPC and warrant
their own PR. This slice proves the consumer→sink→queue pipeline
end-to-end with unit tests and clears the path for the proto additions
to plug in cleanly.

Tests: 10 new unit tests cover field-by-field mapping, the
"unchanged-state-doesn't-emit" filter, the state→transition kind table,
Subscribe / Acknowledge passthrough, SnapshotActiveAlarms → proto
ActiveAlarmSnapshot mapping, and Dispose detaches the handler. All
passing; total worker test count 172/3 skip / 1 pre-existing structure
fail (untouched).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-01 09:52:35 -04:00