Issue #23: implement sta runtime and message pump
This commit is contained in:
@@ -250,6 +250,17 @@ The loop should update a heartbeat timestamp after:
|
||||
- finishing a command,
|
||||
- processing an MXAccess event.
|
||||
|
||||
`StaRuntime` implements this runtime boundary in the worker. It starts one
|
||||
background thread named `MxGateway.Worker.STA`, sets it to `ApartmentState.STA`,
|
||||
initializes COM through `StaComApartmentInitializer`, and runs
|
||||
`StaMessagePump`. Commands are scheduled through `InvokeAsync`; the command
|
||||
queue signals an `AutoResetEvent` so `MsgWaitForMultipleObjectsEx` can wake the
|
||||
STA without busy-waiting. `LastActivityUtc` records pump, command, startup, and
|
||||
shutdown activity so the future heartbeat/watchdog can report whether the STA
|
||||
is still responsive. Shutdown marks the runtime as closing, wakes the pump,
|
||||
rejects new commands, cancels queued work, uninitializes COM on the STA, and
|
||||
waits for the thread to exit.
|
||||
|
||||
## COM Creation
|
||||
|
||||
The MXAccess analysis source at `C:\Users\dohertj2\Desktop\mxaccess` identifies
|
||||
|
||||