Issue #23: implement sta runtime and message pump

This commit is contained in:
Joseph Doherty
2026-04-26 17:18:53 -04:00
parent 603aff7004
commit e81682e367
8 changed files with 659 additions and 0 deletions
+11
View File
@@ -250,6 +250,17 @@ The loop should update a heartbeat timestamp after:
- finishing a command,
- processing an MXAccess event.
`StaRuntime` implements this runtime boundary in the worker. It starts one
background thread named `MxGateway.Worker.STA`, sets it to `ApartmentState.STA`,
initializes COM through `StaComApartmentInitializer`, and runs
`StaMessagePump`. Commands are scheduled through `InvokeAsync`; the command
queue signals an `AutoResetEvent` so `MsgWaitForMultipleObjectsEx` can wake the
STA without busy-waiting. `LastActivityUtc` records pump, command, startup, and
shutdown activity so the future heartbeat/watchdog can report whether the STA
is still responsive. Shutdown marks the runtime as closing, wakes the pump,
rejects new commands, cancels queued work, uninitializes COM on the STA, and
waits for the thread to exit.
## COM Creation
The MXAccess analysis source at `C:\Users\dohertj2\Desktop\mxaccess` identifies