rename: prefix gateway projects/namespaces with ZB.MOM.WW + sln→slnx

Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.

External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
  MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths

Also fixes two tests that were not rename-related but became visible
while validating the rename:

- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
  gateway service correctly maps to RpcException(Cancelled) per gRPC
  convention was being misclassified as a stream fault. Added a sibling
  catch on RpcException with StatusCode.Cancelled.

- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
  and made it accept either a .git marker OR a .sln/.slnx next to src/
  so the worker-exe walker works in non-git working copies.

clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.

Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
  Tests: 472/472 pass
  Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
  IntegrationTests: 18/18 pass

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-23 16:22:23 -04:00
parent 867bf18116
commit dc9c0c950c
491 changed files with 32854 additions and 8414 deletions
@@ -0,0 +1,254 @@
using System;
using ArchestrA.MxAccess;
using Proto = ZB.MOM.WW.MxGateway.Contracts.Proto;
namespace ZB.MOM.WW.MxGateway.Worker.MxAccess;
/// <summary>Sink for MXAccess COM events that converts them to protobuf format.</summary>
public sealed class MxAccessBaseEventSink : IMxAccessEventSink
{
private readonly MxAccessEventMapper eventMapper;
private readonly MxAccessEventQueue eventQueue;
private readonly MxAccessValueCache valueCache;
private LMXProxyServerClass? server;
private string sessionId = string.Empty;
/// <summary>Initializes a new instance of the MxAccessBaseEventSink class with a default queue.</summary>
public MxAccessBaseEventSink()
: this(new MxAccessEventQueue())
{
}
/// <summary>Initializes a new instance of the MxAccessBaseEventSink class with a provided queue.</summary>
/// <param name="eventQueue">Queue for buffering converted MXAccess events.</param>
public MxAccessBaseEventSink(MxAccessEventQueue eventQueue)
: this(eventQueue, new MxAccessEventMapper(), new MxAccessValueCache())
{
}
/// <summary>Initializes a new instance of the MxAccessBaseEventSink class with provided queue and mapper.</summary>
/// <param name="eventQueue">Queue for buffering converted MXAccess events.</param>
/// <param name="eventMapper">Converter for MXAccess events to protobuf format.</param>
public MxAccessBaseEventSink(
MxAccessEventQueue eventQueue,
MxAccessEventMapper eventMapper)
: this(eventQueue, eventMapper, new MxAccessValueCache())
{
}
/// <summary>
/// Initializes a new instance of the MxAccessBaseEventSink class with
/// provided queue, mapper, and a shared value cache. The cache is
/// populated from every successful <c>OnDataChange</c> dispatch so the
/// worker's ReadBulk executor can satisfy a "current value" request
/// from an already-advised tag without touching the subscription.
/// </summary>
/// <param name="eventQueue">Queue for buffering converted MXAccess events.</param>
/// <param name="eventMapper">Converter for MXAccess events to protobuf format.</param>
/// <param name="valueCache">Per-session last-value cache shared with the MxAccessSession.</param>
public MxAccessBaseEventSink(
MxAccessEventQueue eventQueue,
MxAccessEventMapper eventMapper,
MxAccessValueCache valueCache)
{
this.eventQueue = eventQueue ?? throw new ArgumentNullException(nameof(eventQueue));
this.eventMapper = eventMapper ?? throw new ArgumentNullException(nameof(eventMapper));
this.valueCache = valueCache ?? throw new ArgumentNullException(nameof(valueCache));
}
/// <summary>
/// The last-value cache populated by this sink. Exposed so the
/// MxAccessSession can share the same instance for ReadBulk lookups.
/// </summary>
public MxAccessValueCache ValueCache => valueCache;
/// <inheritdoc />
public void Attach(
object mxAccessComObject,
string sessionId)
{
this.sessionId = sessionId ?? string.Empty;
server = (LMXProxyServerClass)mxAccessComObject;
server.OnDataChange += OnDataChange;
server.OnWriteComplete += OnWriteComplete;
server.OperationComplete += OperationComplete;
server.OnBufferedDataChange += OnBufferedDataChange;
}
/// <inheritdoc />
public void Detach()
{
if (server is null)
{
return;
}
server.OnDataChange -= OnDataChange;
server.OnWriteComplete -= OnWriteComplete;
server.OperationComplete -= OperationComplete;
server.OnBufferedDataChange -= OnBufferedDataChange;
server = null;
sessionId = string.Empty;
}
/// <summary>
/// Handles the MXAccess <c>OnDataChange</c> COM event: converts the
/// event arguments to a protobuf <see cref="Proto.MxEvent"/> and enqueues
/// it. Subscribed to the COM object's event in <see cref="Attach"/>.
/// Exposed <c>internal</c> so unit tests can drive the integrated
/// sink → mapper → queue path without a live MXAccess COM event source.
/// </summary>
internal void OnDataChange(
int hLMXServerHandle,
int phItemHandle,
object pvItemValue,
int pwItemQuality,
object pftItemTimeStamp,
ref MXSTATUS_PROXY[] pVars)
{
MXSTATUS_PROXY[] statuses = pVars;
// Build the protobuf event once, enqueue it for the outbound stream, and
// also publish it into the per-session value cache so ReadBulk can serve
// it as a "current value" without re-advising. The cache update is the
// ONLY new side effect — fail-fast on conversion still drops the event
// through the same EnqueueEvent path as before.
EnqueueEvent(
() => eventMapper.CreateOnDataChange(
sessionId,
hLMXServerHandle,
phItemHandle,
pvItemValue,
pwItemQuality,
pftItemTimeStamp,
statuses),
mxEvent => valueCache.Set(hLMXServerHandle, phItemHandle, mxEvent));
}
/// <summary>
/// Handles the MXAccess <c>OnWriteComplete</c> COM event. Exposed
/// <c>internal</c> as a unit-test seam; see <see cref="OnDataChange"/>.
/// </summary>
internal void OnWriteComplete(
int hLMXServerHandle,
int phItemHandle,
ref MXSTATUS_PROXY[] pVars)
{
MXSTATUS_PROXY[] statuses = pVars;
EnqueueEvent(() => eventMapper.CreateOnWriteComplete(
sessionId,
hLMXServerHandle,
phItemHandle,
statuses));
}
/// <summary>
/// Handles the MXAccess <c>OperationComplete</c> COM event. Exposed
/// <c>internal</c> as a unit-test seam; see <see cref="OnDataChange"/>.
/// </summary>
internal void OperationComplete(
int hLMXServerHandle,
int phItemHandle,
ref MXSTATUS_PROXY[] pVars)
{
MXSTATUS_PROXY[] statuses = pVars;
EnqueueEvent(() => eventMapper.CreateOperationComplete(
sessionId,
hLMXServerHandle,
phItemHandle,
statuses));
}
/// <summary>
/// Handles the MXAccess <c>OnBufferedDataChange</c> COM event. Exposed
/// <c>internal</c> as a unit-test seam; see <see cref="OnDataChange"/>.
/// </summary>
internal void OnBufferedDataChange(
int hLMXServerHandle,
int phItemHandle,
MxDataType dtDataType,
object pvItemValue,
object pwItemQuality,
object pftItemTimeStamp,
ref MXSTATUS_PROXY[] pVars)
{
MXSTATUS_PROXY[] statuses = pVars;
EnqueueEvent(() => eventMapper.CreateOnBufferedDataChange(
sessionId,
hLMXServerHandle,
phItemHandle,
(int)dtDataType,
pvItemValue,
pwItemQuality,
pftItemTimeStamp,
statuses));
}
private void EnqueueEvent(Func<Proto.MxEvent> createEvent)
{
EnqueueEvent(createEvent, postPublish: null);
}
private void EnqueueEvent(Func<Proto.MxEvent> createEvent, Action<Proto.MxEvent>? postPublish)
{
Proto.MxEvent mxEvent;
try
{
mxEvent = createEvent();
}
catch (Exception exception)
{
eventQueue.RecordFault(CreateEventConversionFault(exception));
return;
}
try
{
eventQueue.Enqueue(mxEvent);
}
catch (Exception exception)
{
// Two distinct failures land here, both intentionally fail-fast:
// - A conversion failure from createEvent() — recorded here as an
// MxaccessEventConversionFailed fault.
// - An MxAccessEventQueueOverflowException from Enqueue when the
// queue is at capacity. Per the fail-fast backpressure design
// (docs/DesignDecisions.md) the event is dropped and the queue
// has *already* self-recorded a QueueOverflow fault. Because
// MxAccessEventQueue.RecordFault keeps only the first fault,
// this catch's RecordFault call is then a deliberate near
// no-op rather than a second, conflicting fault.
eventQueue.RecordFault(CreateEventConversionFault(exception));
return;
}
// Only publish to caches/observers after the event has cleared the
// queue, so a queue overflow does not leak a "fresher" cached value
// than what was actually shipped to the gateway.
if (postPublish is not null)
{
try
{
postPublish(mxEvent);
}
catch (Exception exception)
{
eventQueue.RecordFault(CreateEventConversionFault(exception));
}
}
}
private Proto.WorkerFault CreateEventConversionFault(Exception exception)
{
return new Proto.WorkerFault
{
Category = Proto.WorkerFaultCategory.MxaccessEventConversionFailed,
ExceptionType = exception.GetType().FullName ?? string.Empty,
DiagnosticMessage = $"{exception.GetType().FullName}: HRESULT 0x{unchecked((uint)exception.HResult):X8}",
ProtocolStatus = new Proto.ProtocolStatus
{
Code = Proto.ProtocolStatusCode.MxaccessFailure,
Message = "MXAccess event conversion failed.",
},
};
}
}