rename: prefix gateway projects/namespaces with ZB.MOM.WW + sln→slnx

Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.

External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
  MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths

Also fixes two tests that were not rename-related but became visible
while validating the rename:

- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
  gateway service correctly maps to RpcException(Cancelled) per gRPC
  convention was being misclassified as a stream fault. Added a sibling
  catch on RpcException with StatusCode.Cancelled.

- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
  and made it accept either a .git marker OR a .sln/.slnx next to src/
  so the worker-exe walker works in non-git working copies.

clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.

Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
  Tests: 472/472 pass
  Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
  IntegrationTests: 18/18 pass

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-23 16:22:23 -04:00
parent 867bf18116
commit dc9c0c950c
491 changed files with 32854 additions and 8414 deletions
@@ -0,0 +1,87 @@
using System.Buffers.Binary;
using Google.Protobuf;
using ZB.MOM.WW.MxGateway.Contracts.Proto;
namespace ZB.MOM.WW.MxGateway.Server.Workers;
public sealed class WorkerFrameReader
{
private readonly WorkerFrameProtocolOptions _options;
private readonly Stream _stream;
/// <summary>
/// Initializes a new instance of <see cref="WorkerFrameReader"/>.
/// </summary>
/// <param name="stream">Stream to read frames from.</param>
/// <param name="options">Frame protocol options.</param>
public WorkerFrameReader(
Stream stream,
WorkerFrameProtocolOptions options)
{
_stream = stream ?? throw new ArgumentNullException(nameof(stream));
_options = options ?? throw new ArgumentNullException(nameof(options));
}
/// <summary>
/// Reads a worker envelope frame from the stream asynchronously.
/// </summary>
/// <param name="cancellationToken">Cancellation token.</param>
/// <returns>Parsed worker envelope.</returns>
public async ValueTask<WorkerEnvelope> ReadAsync(CancellationToken cancellationToken = default)
{
byte[] lengthPrefix = new byte[sizeof(uint)];
await ReadExactlyOrThrowAsync(lengthPrefix, cancellationToken).ConfigureAwait(false);
uint payloadLength = BinaryPrimitives.ReadUInt32LittleEndian(lengthPrefix);
if (payloadLength == 0)
{
throw new WorkerFrameProtocolException(
WorkerFrameProtocolErrorCode.MalformedLength,
"Worker frame payload length must be greater than zero.");
}
if (payloadLength > _options.MaxMessageBytes)
{
throw new WorkerFrameProtocolException(
WorkerFrameProtocolErrorCode.MessageTooLarge,
$"Worker frame payload length {payloadLength} exceeds the configured maximum of {_options.MaxMessageBytes} bytes.");
}
byte[] payload = new byte[payloadLength];
await ReadExactlyOrThrowAsync(payload, cancellationToken).ConfigureAwait(false);
WorkerEnvelope envelope;
try
{
envelope = WorkerEnvelope.Parser.ParseFrom(payload);
}
catch (InvalidProtocolBufferException exception)
{
throw new WorkerFrameProtocolException(
WorkerFrameProtocolErrorCode.InvalidEnvelope,
"Worker frame payload is not a valid WorkerEnvelope protobuf message.",
exception);
}
WorkerEnvelopeValidator.Validate(envelope, _options);
return envelope;
}
private async ValueTask ReadExactlyOrThrowAsync(
Memory<byte> buffer,
CancellationToken cancellationToken)
{
try
{
await _stream.ReadExactlyAsync(buffer, cancellationToken).ConfigureAwait(false);
}
catch (EndOfStreamException exception)
{
throw new WorkerFrameProtocolException(
WorkerFrameProtocolErrorCode.EndOfStream,
"Worker frame ended before the expected number of bytes were read.",
exception);
}
}
}