rename: prefix gateway projects/namespaces with ZB.MOM.WW + sln→slnx

Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.

External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
  MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths

Also fixes two tests that were not rename-related but became visible
while validating the rename:

- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
  gateway service correctly maps to RpcException(Cancelled) per gRPC
  convention was being misclassified as a stream fault. Added a sibling
  catch on RpcException with StatusCode.Cancelled.

- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
  and made it accept either a .git marker OR a .sln/.slnx next to src/
  so the worker-exe walker works in non-git working copies.

clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.

Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
  Tests: 472/472 pass
  Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
  IntegrationTests: 18/18 pass

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
Joseph Doherty
2026-05-23 16:22:23 -04:00
parent 867bf18116
commit dc9c0c950c
491 changed files with 32854 additions and 8414 deletions
@@ -0,0 +1,143 @@
syntax = "proto3";
package galaxy_repository.v1;
option csharp_namespace = "ZB.MOM.WW.MxGateway.Contracts.Proto.Galaxy";
import "google/protobuf/timestamp.proto";
import "google/protobuf/wrappers.proto";
// Wire-compatibility policy (ProtobufStyleGuide): this contract evolves
// additively only. Never renumber or repurpose an existing field number or
// enum value. When a field or enum value is removed, add a `reserved` range
// (and `reserved` name) covering it in the same change so a future editor
// cannot accidentally reuse the retired tag. There are no `reserved`
// declarations today because no field or enum value has ever been removed.
// Read-only browse over the AVEVA System Platform Galaxy Repository (ZB SQL
// database). Lets clients enumerate the deployed object hierarchy and each
// object's dynamic attributes so they know what tag references to subscribe
// to via the MxAccessGateway service.
service GalaxyRepository {
rpc TestConnection(TestConnectionRequest) returns (TestConnectionReply);
rpc GetLastDeployTime(GetLastDeployTimeRequest) returns (GetLastDeployTimeReply);
rpc DiscoverHierarchy(DiscoverHierarchyRequest) returns (DiscoverHierarchyReply);
// Server-stream of deploy events. The server emits the current state immediately
// on subscribe (so clients can bootstrap their cache without waiting for the next
// deploy), then emits one event each time the gateway's hierarchy cache observes
// a new galaxy.time_of_last_deploy. The sequence field is monotonically
// increasing per server start; gaps indicate the per-subscriber buffer dropped
// older events because the client was too slow.
rpc WatchDeployEvents(WatchDeployEventsRequest) returns (stream DeployEvent);
}
message TestConnectionRequest {}
message TestConnectionReply {
bool ok = 1;
}
message GetLastDeployTimeRequest {}
message GetLastDeployTimeReply {
bool present = 1;
google.protobuf.Timestamp time_of_last_deploy = 2;
}
message DiscoverHierarchyRequest {
// Maximum number of objects to return. The server applies its default when
// unset and rejects non-positive values.
int32 page_size = 1;
// Opaque token returned by a previous DiscoverHierarchy response.
string page_token = 2;
// Optional. When set, return only this object and its descendants.
// Empty = full hierarchy.
oneof root {
int32 root_gobject_id = 3;
string root_tag_name = 4;
string root_contained_path = 5;
}
// Optional. Cap on descendant depth from root. Zero returns only the root.
// Unset means unlimited depth.
google.protobuf.Int32Value max_depth = 6;
// Optional object category id filters.
repeated int32 category_ids = 7;
// Optional case-insensitive substring filters against template names.
repeated string template_chain_contains = 8;
// Optional anchored, case-insensitive glob over object tag_name.
string tag_name_glob = 9;
// Optional. Unset or true includes attributes. False returns object skeletons.
optional bool include_attributes = 10;
// Optional. Return only objects with at least one alarm-bearing attribute.
bool alarm_bearing_only = 11;
// Optional. Return only objects with at least one historized attribute.
bool historized_only = 12;
}
message DiscoverHierarchyReply {
repeated GalaxyObject objects = 1;
// Non-empty when another page is available.
string next_page_token = 2;
// Total number of objects in the cached hierarchy at the time of the call.
int32 total_object_count = 3;
}
message WatchDeployEventsRequest {
// Optional. When set, the bootstrap event is suppressed if the cached deploy
// time matches this value. Future events are still emitted normally.
google.protobuf.Timestamp last_seen_deploy_time = 1;
}
message DeployEvent {
// Monotonically increasing per server start. Gaps indicate dropped events.
uint64 sequence = 1;
// Server wall-clock when the cache observed the deploy.
google.protobuf.Timestamp observed_at = 2;
// Galaxy.time_of_last_deploy. Absent only when the Galaxy table reports null.
google.protobuf.Timestamp time_of_last_deploy = 3;
bool time_of_last_deploy_present = 4;
int32 object_count = 5;
int32 attribute_count = 6;
}
message GalaxyObject {
int32 gobject_id = 1;
string tag_name = 2;
string contained_name = 3;
string browse_name = 4;
int32 parent_gobject_id = 5;
bool is_area = 6;
int32 category_id = 7;
int32 hosted_by_gobject_id = 8;
repeated string template_chain = 9;
repeated GalaxyAttribute attributes = 10;
}
message GalaxyAttribute {
string attribute_name = 1;
string full_tag_reference = 2;
// Raw Galaxy SQL `dbo.data_type` identifier, passed through unchanged.
// This is NOT a member of `mxaccess_gateway.v1.MxDataType` — Galaxy's
// type enumeration is distinct from MXAccess's wire data-type enum and
// the two must not be cast or compared. The GalaxyRepository service is
// metadata-only and deliberately does not share types with
// mxaccess_gateway.proto. See docs/GalaxyRepository.md.
int32 mx_data_type = 3;
// Human-readable name from Galaxy's `dbo.data_type` table (e.g. "Float",
// "Integer", "Boolean"). Free-form Galaxy text; not a stable enum.
string data_type_name = 4;
bool is_array = 5;
int32 array_dimension = 6;
bool array_dimension_present = 7;
// Raw Galaxy SQL attribute-category identifier, passed through unchanged.
// Galaxy-specific; not mapped to any gateway enum. See
// docs/GalaxyRepository.md.
int32 mx_attribute_category = 8;
// Raw Galaxy SQL security-classification identifier, passed through
// unchanged. Galaxy-specific; not mapped to any gateway enum. See
// docs/GalaxyRepository.md.
int32 security_classification = 9;
bool is_historized = 10;
bool is_alarm = 11;
}
File diff suppressed because it is too large Load Diff
@@ -0,0 +1,132 @@
syntax = "proto3";
package mxaccess_worker.v1;
option csharp_namespace = "ZB.MOM.WW.MxGateway.Contracts.Proto";
import "google/protobuf/duration.proto";
import "google/protobuf/timestamp.proto";
import "mxaccess_gateway.proto";
// Wire-compatibility policy (ProtobufStyleGuide): this contract evolves
// additively only. Never renumber or repurpose an existing field number or
// enum value. When a field or enum value is removed, add a `reserved` range
// (and `reserved` name) covering it in the same change so a future editor
// cannot accidentally reuse the retired tag. There are no `reserved`
// declarations today because no field or enum value has ever been removed.
// Gateway-to-worker IPC envelope. Named-pipe framing prepends a little-endian
// uint32 payload length to this protobuf payload.
message WorkerEnvelope {
uint32 protocol_version = 1;
string session_id = 2;
uint64 sequence = 3;
string correlation_id = 4;
oneof body {
GatewayHello gateway_hello = 10;
WorkerHello worker_hello = 11;
WorkerReady worker_ready = 12;
WorkerCommand worker_command = 13;
WorkerCommandReply worker_command_reply = 14;
WorkerCancel worker_cancel = 15;
WorkerShutdown worker_shutdown = 16;
WorkerShutdownAck worker_shutdown_ack = 17;
WorkerEvent worker_event = 18;
WorkerHeartbeat worker_heartbeat = 19;
WorkerFault worker_fault = 20;
}
}
message GatewayHello {
uint32 supported_protocol_version = 1;
string nonce = 2;
string gateway_version = 3;
}
message WorkerHello {
uint32 protocol_version = 1;
string nonce = 2;
int32 worker_process_id = 3;
string worker_version = 4;
}
message WorkerReady {
int32 worker_process_id = 1;
string mxaccess_progid = 2;
string mxaccess_clsid = 3;
google.protobuf.Timestamp ready_timestamp = 4;
}
message WorkerCommand {
mxaccess_gateway.v1.MxCommand command = 1;
google.protobuf.Timestamp enqueue_timestamp = 2;
}
message WorkerCommandReply {
mxaccess_gateway.v1.MxCommandReply reply = 1;
google.protobuf.Timestamp completed_timestamp = 2;
}
message WorkerCancel {
string reason = 1;
}
message WorkerShutdown {
google.protobuf.Duration grace_period = 1;
string reason = 2;
}
message WorkerShutdownAck {
mxaccess_gateway.v1.ProtocolStatus status = 1;
}
message WorkerEvent {
mxaccess_gateway.v1.MxEvent event = 1;
}
message WorkerHeartbeat {
int32 worker_process_id = 1;
WorkerState state = 2;
google.protobuf.Timestamp last_sta_activity_timestamp = 3;
uint32 pending_command_count = 4;
uint32 outbound_event_queue_depth = 5;
uint64 last_event_sequence = 6;
string current_command_correlation_id = 7;
}
message WorkerFault {
WorkerFaultCategory category = 1;
string command_method = 2;
optional int32 hresult = 3;
string exception_type = 4;
string diagnostic_message = 5;
mxaccess_gateway.v1.ProtocolStatus protocol_status = 6;
}
enum WorkerState {
WORKER_STATE_UNSPECIFIED = 0;
WORKER_STATE_STARTING = 1;
WORKER_STATE_HANDSHAKING = 2;
WORKER_STATE_INITIALIZING_STA = 3;
WORKER_STATE_READY = 4;
WORKER_STATE_EXECUTING_COMMAND = 5;
WORKER_STATE_SHUTTING_DOWN = 6;
WORKER_STATE_STOPPED = 7;
WORKER_STATE_FAULTED = 8;
}
enum WorkerFaultCategory {
WORKER_FAULT_CATEGORY_UNSPECIFIED = 0;
WORKER_FAULT_CATEGORY_INVALID_ARGUMENTS = 1;
WORKER_FAULT_CATEGORY_GATEWAY_AUTHENTICATION_FAILED = 2;
WORKER_FAULT_CATEGORY_PROTOCOL_MISMATCH = 3;
WORKER_FAULT_CATEGORY_PROTOCOL_VIOLATION = 4;
WORKER_FAULT_CATEGORY_PIPE_DISCONNECTED = 5;
WORKER_FAULT_CATEGORY_MXACCESS_CREATION_FAILED = 6;
WORKER_FAULT_CATEGORY_MXACCESS_COMMAND_FAILED = 7;
WORKER_FAULT_CATEGORY_MXACCESS_EVENT_CONVERSION_FAILED = 8;
WORKER_FAULT_CATEGORY_STA_HUNG = 9;
WORKER_FAULT_CATEGORY_QUEUE_OVERFLOW = 10;