fix(gateway): split the heartbeat check interval from the send interval; expose the two fixed worker-client timeouts (mxaccessgw#192)

R21-O14: MxGateway:Worker:HeartbeatIntervalSeconds was documented as the
worker heartbeat send interval, but it never reached the worker (which sends
on its own fixed 5 s) and only set the gateway's HeartbeatCheckInterval. It is
renamed HeartbeatCheckIntervalSeconds (default 5, unchanged). The old key stays
as a deprecated alias with the same meaning so existing appsettings keep
working; setting both is a validation error. The grace-vs-interval check now
compares against the resolved check interval.

R21-O15: WorkerClientOptions.EventChannelFullModeTimeout and
HeartbeatStuckCeiling were always their compile-time defaults. They are now
MxGateway:Worker:EventChannelFullModeTimeoutMilliseconds (default 5000, > 0)
and HeartbeatStuckCeilingSeconds (default 75, >= HeartbeatGraceSeconds). The
factory's mapping moved into SessionWorkerClientFactory.CreateWorkerClientOptions
so every field is set from configuration and is testable. The effective-config
record shows the resolved check interval and both new values.

Docs: GatewayConfiguration.md, GatewayProcessDesign.md sample,
MxAccessWorkerInstanceDesign.md heartbeat section; appsettings.json uses the
new keys.

Tests: CreateWorkerClientOptions mapping + defaults (fail under a mutated
mapping), alias honoured, both-keys conflict, and bounds for the new options.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
Joseph Doherty
2026-11-09 12:35:42 -05:00
parent 101bda7073
commit 7b21f304e9
15 changed files with 211 additions and 28 deletions
+1 -1
View File
@@ -945,7 +945,7 @@ Suggested configuration shape:
"StartupTimeoutSeconds": 30,
"PipeConnectAttemptTimeoutMilliseconds": 2000,
"ShutdownTimeoutSeconds": 10,
"HeartbeatIntervalSeconds": 5,
"HeartbeatCheckIntervalSeconds": 5,
"HeartbeatGraceSeconds": 15,
"MaxMessageBytes": 16777216
},