# Conflicts:
#	archreview/2026-07-12/remediation/00-tracking.md
#	archreview/2026-07-12/remediation/10-gateway-core.md
This commit is contained in:
Joseph Doherty
2026-08-07 06:02:17 -04:00
19 changed files with 738 additions and 130 deletions
+7 -1
View File
@@ -197,7 +197,13 @@ Event streaming uses `AttachEventSubscriber` which returns a disposable lease. W
`FailFast` event backpressure faults the whole session only in single-subscriber mode; in multi-subscriber mode it degrades to a per-subscriber disconnect so one slow consumer never faults a session shared by others. The session passes its mode to the `SessionEventDistributor` at construction, so this decision is made on the fixed mode rather than a live subscriber-count snapshot.
The single worker event channel has exactly one direct reader: the `SessionEventDistributor` pump (`MapWorkerEventsAsync`). Both gateway-owned internal consumers — the dashboard mirror and the central alarm monitor — attach as distributor subscribers rather than draining the worker channel themselves. `GatewaySession.AttachInternalEventSubscriber` mirrors the dashboard-mirror lease (`isInternal: true`): the alarm monitor's `SessionManager.ReadAlarmEventsAsync` registers one so it consumes the same mapped `MxEvent`s the pump fans to every subscriber, without counting against `MaxEventSubscribersPerSession` and without a slow reconcile faulting the session. This is what keeps the alarm feed and the dashboard from splitting the stream between two raw drains (which would silently lose Acknowledge and provider-mode transitions); the worker channel is single-reader and a second `WorkerClient.ReadEventsAsync` consumer throws so a regression fails loudly.
The single worker event channel has exactly one direct reader: the `SessionEventDistributor` pump (`MapWorkerEventsAsync`). Both gateway-owned internal consumers — the dashboard mirror and the central alarm monitor — attach as distributor subscribers rather than draining the worker channel themselves. `GatewaySession.AttachInternalEventSubscriber` mirrors the dashboard-mirror lease (`isInternal: true`): the alarm monitor calls it directly on its session so it consumes the same mapped `MxEvent`s the pump fans to every subscriber, without counting against `MaxEventSubscribersPerSession` and without a slow reconcile faulting the session. This is what keeps the alarm feed and the dashboard from splitting the stream between two raw drains (which would silently lose Acknowledge and provider-mode transitions); the worker channel is single-reader and a second `WorkerClient.ReadEventsAsync` consumer throws so a regression fails loudly.
The monitor takes that lease **before** it issues `SubscribeAlarms`, so no transition window is missed: the pump has been running since `MarkReady` started the dashboard mirror, and the distributor only fans to subscribers registered at fan-out time, so a lease taken after the subscribe + first-reconcile round trips would lose every transition raised inside that window. Transitions arriving while the monitor subscribes and reconciles buffer in the lease's bounded channel and are applied after the reconcile, which is order-safe because a live transition can update an alarm the reconciled snapshot already holds.
The repair transitions the monitor's reconcile broadcasts on the alarm feed (Raise/Clear presence deltas and the acked-state delta) are **at-least-once**: a reconcile reads the worker's current state while the matching live transition may still be buffered in the lease, so both can be broadcast and the duplicates are indistinguishable — alarm-feed consumers must apply transitions idempotently. This is a property of the reconcile design, not of the buffering above.
`AttachInternalEventSubscriber` enforces the same readiness gate as `AttachEventSubscriber` — a session (or worker) that is not `Ready` throws `SessionNotReady` *before* the distributor is constructed. A premature attach would otherwise start the pump against a source that throws, completing every subscriber with that error and latching the distributor for the session's whole lifetime.
Sessions open with `MxGateway:Sessions:DefaultLeaseSeconds` (default 1800) added to the open timestamp. Unary client activity refreshes the lease by the same duration. `ExtendLease` and `IsLeaseExpired` cooperate with `SessionManager.CloseExpiredLeasesAsync`, which iterates a registry snapshot and closes any session whose lease has expired with `LeaseExpiredReason`. `SessionLeaseMonitorHostedService` runs that sweep every `MxGateway:Sessions:LeaseSweepIntervalSeconds` seconds (default 30).