// 1. On the dev rig with AVEVA System Platform installed and Galaxy running:
// $env:MXGATEWAY_RUN_LIVE_MXACCESS_TESTS = "1"
// 2. Remove (or set to null) the Skip parameter on the [Fact] below.
-// 3. Run with an alarm flip script (same one used by AlarmsLiveSmokeTests)
-// so that TestMachine_001.TestAlarm001 toggles its Active/Acked subtags
-// on a ~10 s cadence.
+// 3. Drive a TestMachine alarm so its Active/Acked subtags toggle — either an
+// alarm flip script (same one used by AlarmsLiveSmokeTests, ~10 s cadence)
+// or a manual operator/IDE toggle of the alarm attribute. The rig's
+// TestAlarm attributes are object-driven, so an external MXAccess Write
+// cannot toggle them (confirmed live 2026-06-14 by toggling TestAlarm002
+// from the IDE).
//
// net48/x86 constraints:
// - No init-only properties, records, index/range operators, C# 8+ pattern
@@ -49,8 +52,9 @@ namespace ZB.MOM.WW.MxGateway.Worker.Tests.Probes;
/// writes the
/// ack-comment subtag (AckMsg) successfully.
///
-/// Skip-gated; flip Skip=null on the dev rig with the alarm flip
-/// script running. The remaining live-validation item is confirming that
+/// Skip-gated; flip Skip=null on the dev rig with an alarm being
+/// driven (flip script or a manual operator/IDE toggle of the alarm
+/// attribute). The remaining live-validation item is confirming that
/// the runtime MXAccess item reference path requires no intermediate
/// alarm-condition segment (i.e. <Object>.<AlarmAttr>.InAlarm
/// resolves as-is).
@@ -117,7 +121,7 @@ public sealed class AlarmSubtagLiveSmokeTests
/// the Degraded flag and synthetic GUID are stamped, then
/// AcknowledgeByName and verifies the ack-comment write returns 0.
///
- [Fact(Skip = "Live dev-rig smoke test — flip Skip=null with AVEVA + an alarm flip script running. Subtag fallback path. Field names confirmed (InAlarm/Acked/AckMsg/Priority); live-validate runtime path resolves without intermediate alarm-condition segment.")]
+ [Fact(Skip = "Live dev-rig smoke test — flip Skip=null with AVEVA + an alarm being driven (flip script or manual operator/IDE toggle of the alarm attribute). Subtag fallback path. Field names confirmed (InAlarm/Acked/AckMsg/Priority); live-validate runtime path resolves without intermediate alarm-condition segment.")]
public void SubtagFallback_FullPipelineRoundTrip_SynthesizesRaiseAndAcknowledges()
{
Exception? threadException = null;
@@ -342,9 +346,10 @@ public sealed class AlarmSubtagLiveSmokeTests
consumer.Subscribe(subscriptionExpression);
Log("Subscribe returned OK.");
- // 1. Wait for a Raise transition. The alarm flip script (same one
- // used by AlarmsLiveSmokeTests) writes the active subtag on a
- // ~10 s cadence. LmxSubtagAlarmSource delivers OnDataChange via
+ // 1. Wait for a Raise transition. Whatever is driving the alarm — a
+ // flip script (same one used by AlarmsLiveSmokeTests, ~10 s cadence)
+ // or a manual operator/IDE toggle — writes the active subtag.
+ // LmxSubtagAlarmSource delivers OnDataChange via
// the Windows message pump on the STA, so we must pump messages
// here while we wait — mirroring how AlarmsLiveSmokeTests drives
// its WnWrapAlarmConsumer.PollOnce() from the STA in a tight loop.