feat(worker,gateway): report record-info pin outcome in WorkerReady; drain-thread completion tests
The worker logged its MXSTATUS_PROXY record-info pin outcome only to its own stderr, which the gateway's launcher does not capture, so operators never saw whether the pin took. - Contract (additive, internal IPC): WorkerReady.record_info_pin_status = 5. No protocol version bump; an older peer ignores it or sends it empty. Regenerated Contracts/Generated, the client protoset, the Rust vendored proto, and the Go/Python/Java worker bindings (real delta only). - Worker: the handshake copies MxStatusProxyRecordInfoPin.Status into WorkerReady unless the runtime already set it. - Gateway: WorkerClient records it (IWorkerClient.RecordInfoPinStatus, default null) and logs it at Information when pinned, Warning otherwise; empty is not logged. Shown as "Record-info pin" in the dashboard session details Worker table via DashboardSessionSummary.WorkerRecordInfoPinStatus. - Tests: drain-thread cancellation (task ends Canceled; RunAsync cancels, runtime disposed, thread exits, no EventDrain stop-failure log) and fault (exception on the thread faults RunAsync with the same instance) paths; WorkerReady carries the pin status; gateway logging/recording and the dashboard projection. - Docs: gateway.md STA thread model (drain thread, pin step in COM lifetime), MxAccessWorkerInstanceDesign, GatewayProcessDesign, GatewayDashboardDesign, WorkerFrameProtocol.
This commit is contained in:
@@ -507,6 +507,15 @@ and nonce, waits for `WorkerReady`, and only then exposes `Ready` state. The
|
||||
read loop starts after readiness so the handshake has a single owner for its
|
||||
ordered frames.
|
||||
|
||||
`WorkerReady.record_info_pin_status` carries the worker's `MXSTATUS_PROXY`
|
||||
record-info pin outcome (see `MxAccessWorkerInstanceDesign.md`). The gateway does
|
||||
not capture worker stderr, so `WorkerClient` is where operators see it: a status
|
||||
starting `pinned ` is logged at Information, anything else at Warning, because an
|
||||
unpinned worker pays a type-library reload on every data change. It is kept as
|
||||
`IWorkerClient.RecordInfoPinStatus` and shown on the dashboard's session details
|
||||
page. It never gates readiness, and an empty status (an older worker) is neither
|
||||
logged nor shown.
|
||||
|
||||
### Read loop
|
||||
|
||||
The read loop:
|
||||
|
||||
Reference in New Issue