feat(worker,gateway): report record-info pin outcome in WorkerReady; drain-thread completion tests

The worker logged its MXSTATUS_PROXY record-info pin outcome only to its own
stderr, which the gateway's launcher does not capture, so operators never saw
whether the pin took.

- Contract (additive, internal IPC): WorkerReady.record_info_pin_status = 5.
  No protocol version bump; an older peer ignores it or sends it empty.
  Regenerated Contracts/Generated, the client protoset, the Rust vendored
  proto, and the Go/Python/Java worker bindings (real delta only).
- Worker: the handshake copies MxStatusProxyRecordInfoPin.Status into
  WorkerReady unless the runtime already set it.
- Gateway: WorkerClient records it (IWorkerClient.RecordInfoPinStatus, default
  null) and logs it at Information when pinned, Warning otherwise; empty is
  not logged. Shown as "Record-info pin" in the dashboard session details
  Worker table via DashboardSessionSummary.WorkerRecordInfoPinStatus.
- Tests: drain-thread cancellation (task ends Canceled; RunAsync cancels,
  runtime disposed, thread exits, no EventDrain stop-failure log) and fault
  (exception on the thread faults RunAsync with the same instance) paths;
  WorkerReady carries the pin status; gateway logging/recording and the
  dashboard projection.
- Docs: gateway.md STA thread model (drain thread, pin step in COM lifetime),
  MxAccessWorkerInstanceDesign, GatewayProcessDesign, GatewayDashboardDesign,
  WorkerFrameProtocol.
This commit is contained in:
Joseph Doherty
2026-11-21 08:11:31 -05:00
parent 659bb831a2
commit 30ac3f3225
23 changed files with 878 additions and 145 deletions
+11
View File
@@ -65,6 +65,13 @@ message WorkerReady {
string mxaccess_progid = 2;
string mxaccess_clsid = 3;
google.protobuf.Timestamp ready_timestamp = 4;
// Outcome of the worker's process-wide MXSTATUS_PROXY record-info pin
// (MxStatusProxyRecordInfoPin): "pinned {library-guid} vM.m record {record-guid}" on
// success, or the failing call and HRESULT / exception type otherwise. Empty when the
// worker made no attempt (an older worker, or a runtime that never created the
// MXAccess COM object). Diagnostic only: the gateway logs it and shows it on the
// dashboard, and never gates readiness on it, because the pin is a cache warm-up.
string record_info_pin_status = 5;
}
message WorkerCommand {
@@ -127,6 +134,10 @@ enum WorkerState {
enum WorkerFaultCategory {
WORKER_FAULT_CATEGORY_UNSPECIFIED = 0;
// Values 1 and 2 are reserved: never emitted. Bootstrap failures (bad
// arguments, gateway authentication) exit via WorkerExitCode before the pipe
// exists, so there is no channel to carry a fault. Names kept so the numbers
// are not reused.
WORKER_FAULT_CATEGORY_INVALID_ARGUMENTS = 1;
WORKER_FAULT_CATEGORY_GATEWAY_AUTHENTICATION_FAILED = 2;
WORKER_FAULT_CATEGORY_PROTOCOL_MISMATCH = 3;