fix(historian): read-only historian bindings + ProvisionTags policy; provision OPC UA type names (#899, #898)
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via
historianTagname re-typed/re-described it on every add and host start.
- TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly):
  HistoryRead from an existing historian tag that OtOpcUa never provisions and never
  records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags
  hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the
  RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid.
  AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the
  runtime parse.
- ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly
  (Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not
  sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start.
- Default for an explicit historianTagname stays OWNED: overrides pin owned history
  across renames, a read-only default would silently stop provisioning + recording.

#898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized
Float/Double/Byte/SByte tags were never provisioned. New shared
HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16
(lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips
Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject).

UPGRADE: the first host start after this provisions (upserts) every existing historized
Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set
ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md).

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 01:16:24 -05:00

143 lines
10 KiB
C#

using System.Text.Json;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
using ZB.MOM.WW.OtOpcUa.Configuration.Enums;
using ZB.MOM.WW.OtOpcUa.OpcUaServer;
using ZB.MOM.WW.OtOpcUa.Runtime.Drivers;
namespace ZB.MOM.WW.OtOpcUa.Runtime.Tests.Drivers;
/// <summary>
/// v3 Batch 4 (Wave-B review recommendation) — the artifact-decode seam
/// (<see cref="DeploymentArtifact.ParseComposition(System.ReadOnlySpan{byte})"/>) and the live compose seam
/// (<see cref="AddressSpaceComposer.Compose"/>) must produce BYTE-IDENTICAL <b>Raw</b> and <b>UNS</b> node
/// sets for the same seeded config. This is the guard that a future artifact-decode drift can't silently
/// diverge the deployed dual-namespace address space from what was authored/validated. The existing
/// <c>DeploymentArtifactEquipRefParityTests</c> covers <c>{{equip}}</c> script-path parity; this covers the
/// RawContainers / RawTags / UnsReferenceVariables sets (RawPaths, UNS NodeIds, Organizes backing paths,
/// writable + historian + array shape).
/// </summary>
public sealed class DeploymentArtifactRawUnsParityTests
{
private const string RunTagConfig = "{\"isHistorized\":true,\"historianTagname\":\"SysPulse\",\"historianReadOnly\":true}";
[Fact]
public void Raw_and_uns_node_sets_are_byte_parity_between_compose_and_artifact_decode()
{
// Entity-side config: folder → driver → device → group → 4 tags, an area/line/equipment, and a UNS
// reference with a display-name override. The four tags cover every per-field intent RawTagPlan
// carries: historize (+ tagname override), plain read-only, ARRAY (isArray + arrayLength), and
// NATIVE ALARM (a TagConfig.alarm object → EquipmentTagAlarmInfo).
//
// The array and alarm tags were folded in here when the three placeholder suites
// (DeploymentArtifact{Array,Historize,Alias}ParityTests) were deleted — they had been parked on
// "unskip when Batch 4 lights the equipment-tag plans", but Batch 4 RETIRED equipment-tag plans
// instead of lighting them, so their subject moved onto the raw tag and belongs in this comparison.
var folder = new RawFolder { RawFolderId = "fld-1", ClusterId = "c1", Name = "Cell1", ParentRawFolderId = null };
var driver = new DriverInstance { DriverInstanceId = "drv-1", ClusterId = "c1", Name = "Modbus", DriverType = "Modbus", DriverConfig = "{}", RawFolderId = "fld-1" };
var device = new Device { DeviceId = "dev-1", DriverInstanceId = "drv-1", Name = "Dev1", DeviceConfig = "{}" };
var group = new TagGroup { TagGroupId = "grp-1", DeviceId = "dev-1", Name = "Fast", ParentTagGroupId = null };
var speed = new Tag
{
TagId = "tag-speed", DeviceId = "dev-1", TagGroupId = "grp-1", Name = "Speed", DataType = "Float",
AccessLevel = TagAccessLevel.ReadWrite, TagConfig = "{\"isHistorized\":true,\"historianTagname\":\"WW.Speed\"}",
};
var run = new Tag
{
TagId = "tag-run", DeviceId = "dev-1", TagGroupId = null, Name = "Run", DataType = "Boolean",
// lmxopcua#899: a read-only historian binding — the flag must survive the artifact round-trip.
AccessLevel = TagAccessLevel.Read, TagConfig = RunTagConfig,
};
var profile = new Tag
{
TagId = "tag-profile", DeviceId = "dev-1", TagGroupId = "grp-1", Name = "Profile", DataType = "Float",
AccessLevel = TagAccessLevel.Read, TagConfig = "{\"region\":\"HoldingRegisters\",\"address\":100,\"dataType\":\"Float32\",\"isArray\":true,\"arrayLength\":16}",
};
var tempHi = new Tag
{
TagId = "tag-temphi", DeviceId = "dev-1", TagGroupId = null, Name = "TempHi", DataType = "Boolean",
AccessLevel = TagAccessLevel.ReadWrite,
TagConfig = "{\"alarm\":{\"alarmType\":\"OffNormalAlarm\",\"severity\":700}}",
};
var area = new UnsArea { UnsAreaId = "a1", ClusterId = "c1", Name = "filling" };
var line = new UnsLine { UnsLineId = "l1", UnsAreaId = "a1", Name = "line1" };
var equip = new Equipment { EquipmentId = "EQ-1", UnsLineId = "l1", Name = "station1", MachineCode = "M1" };
var reference = new UnsTagReference { UnsTagReferenceId = "ref-1", EquipmentId = "EQ-1", TagId = "tag-speed", DisplayNameOverride = "MotorSpeed" };
// A second reference onto the ARRAY tag: the UNS reference record carries the backing tag's array
// shape + historian intent (2026-08-15 review), so both branches must survive the artifact round-trip.
var arrayReference = new UnsTagReference { UnsTagReferenceId = "ref-2", EquipmentId = "EQ-1", TagId = "tag-profile", DisplayNameOverride = null };
var composed = AddressSpaceComposer.Compose(
new[] { area }, new[] { line }, new[] { equip },
new[] { driver }, Array.Empty<ScriptedAlarm>(),
unsTagReferences: new[] { reference, arrayReference }, tags: new[] { speed, run, profile, tempHi },
rawFolders: new[] { folder }, devices: new[] { device }, tagGroups: new[] { group });
// Artifact JSON — the same shape ConfigComposer serializes (enums numeric: ReadWrite = 1, Read = 0).
var blob = JsonSerializer.SerializeToUtf8Bytes(new
{
RawFolders = new[] { new { RawFolderId = "fld-1", ParentRawFolderId = (string?)null, Name = "Cell1", ClusterId = "c1" } },
DriverInstances = new[] { new { DriverInstanceId = "drv-1", DriverType = "Modbus", DriverConfig = "{}", Name = "Modbus", RawFolderId = "fld-1", ClusterId = "c1" } },
Devices = new[] { new { DeviceId = "dev-1", DriverInstanceId = "drv-1", Name = "Dev1", DeviceConfig = "{}" } },
TagGroups = new[] { new { TagGroupId = "grp-1", ParentTagGroupId = (string?)null, DeviceId = "dev-1", Name = "Fast" } },
Tags = new object[]
{
new { TagId = "tag-speed", DeviceId = "dev-1", TagGroupId = "grp-1", Name = "Speed", DataType = "Float", AccessLevel = 1, TagConfig = "{\"isHistorized\":true,\"historianTagname\":\"WW.Speed\"}" },
new { TagId = "tag-run", DeviceId = "dev-1", TagGroupId = (string?)null, Name = "Run", DataType = "Boolean", AccessLevel = 0, TagConfig = RunTagConfig },
new { TagId = "tag-profile", DeviceId = "dev-1", TagGroupId = "grp-1", Name = "Profile", DataType = "Float", AccessLevel = 0, TagConfig = "{\"region\":\"HoldingRegisters\",\"address\":100,\"dataType\":\"Float32\",\"isArray\":true,\"arrayLength\":16}" },
new { TagId = "tag-temphi", DeviceId = "dev-1", TagGroupId = (string?)null, Name = "TempHi", DataType = "Boolean", AccessLevel = 1, TagConfig = "{\"alarm\":{\"alarmType\":\"OffNormalAlarm\",\"severity\":700}}" },
},
UnsAreas = new[] { new { UnsAreaId = "a1", Name = "filling", ClusterId = "c1" } },
UnsLines = new[] { new { UnsLineId = "l1", UnsAreaId = "a1", Name = "line1" } },
Equipment = new[] { new { EquipmentId = "EQ-1", UnsLineId = "l1", Name = "station1", MachineCode = "M1" } },
UnsTagReferences = new[]
{
new { UnsTagReferenceId = "ref-1", EquipmentId = "EQ-1", TagId = "tag-speed", DisplayNameOverride = (string?)"MotorSpeed" },
new { UnsTagReferenceId = "ref-2", EquipmentId = "EQ-1", TagId = "tag-profile", DisplayNameOverride = (string?)null },
},
});
var decoded = DeploymentArtifact.ParseComposition(blob);
// Sanity: the sets are non-empty (all four raw tags + the projected UNS variable materialised).
composed.RawTags.Count.ShouldBe(4);
// Sanity on the two folded-in branches — without these, a composer that dropped array/alarm intent
// ENTIRELY would still pass the parity assertion below, because the artifact decode would drop it too
// and the two empties would compare equal. Parity alone cannot tell "both right" from "both blind".
var composedArray = composed.RawTags.Single(t => t.Name == "Profile");
composedArray.IsArray.ShouldBeTrue();
composedArray.ArrayLength.ShouldBe(16u);
composedArray.ArrayWritable.ShouldBeTrue(); // #610: a Modbus holding-register Float32 array is writable
var composedAlarm = composed.RawTags.Single(t => t.Name == "TempHi");
composedAlarm.Alarm.ShouldNotBeNull();
composedAlarm.Alarm!.AlarmType.ShouldBe("OffNormalAlarm");
composedAlarm.Writable.ShouldBeTrue();
var composedRun = composed.RawTags.Single(t => t.Name == "Run");
composedRun.IsHistorized.ShouldBeTrue();
composedRun.HistorianReadOnly.ShouldBeTrue();
composed.RawTags.Single(t => t.Name == "Speed").HistorianReadOnly.ShouldBeFalse();
composed.UnsReferenceVariables.Count.ShouldBe(2);
var composedSpeedRef = composed.UnsReferenceVariables.Single(v => v.UnsTagReferenceId == "ref-1");
composedSpeedRef.NodeId.ShouldBe("filling/line1/station1/MotorSpeed");
composedSpeedRef.BackingRawPath.ShouldBe("Cell1/Modbus/Dev1/Fast/Speed");
// Same "both right, not both blind" sanity for the backing historian intent + array shape the UNS
// reference inherits — a composer that dropped them entirely would parity-match a decode that did too.
composedSpeedRef.BackingIsHistorized.ShouldBeTrue();
composedSpeedRef.BackingHistorianTagname.ShouldBe("WW.Speed");
composedSpeedRef.BackingIsArray.ShouldBeFalse();
var composedProfileRef = composed.UnsReferenceVariables.Single(v => v.UnsTagReferenceId == "ref-2");
composedProfileRef.BackingIsArray.ShouldBeTrue();
composedProfileRef.BackingArrayLength.ShouldBe(16u);
composedProfileRef.BackingArrayWritable.ShouldBeTrue();
composedProfileRef.BackingIsHistorized.ShouldBeFalse();
// Byte-parity: the three dual-namespace node sets are record-equal between the two seams.
decoded.RawContainers.ShouldBe(composed.RawContainers);
decoded.RawTags.ShouldBe(composed.RawTags);
decoded.UnsReferenceVariables.ShouldBe(composed.UnsReferenceVariables);
}
}