Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host/Sta
Joseph Doherty 32eeeb9e04 Phase 2 Streams A+B+C feature-complete — real Win32 pump, all 9 IDriver capabilities, end-to-end IPC dispatch. Streams D+E remain (Galaxy MXAccess code lift + parity-debug cycle, plan-budgeted 3-4 weeks). The 494 v1 IntegrationTests still pass — legacy OtOpcUa.Host untouched. StaPump replaces the BlockingCollection placeholder with a real Win32 message pump lifted from v1 StaComThread per CLAUDE.md "Reference Implementation": dedicated STA Thread with SetApartmentState(STA), GetMessage/PostThreadMessage/PeekMessage/TranslateMessage/DispatchMessage/PostQuitMessage P/Invoke, WM_APP=0x8000 for work-item dispatch, WM_APP+1 for graceful-drain → PostQuitMessage, peek-pm-noremove on entry to force the system to create the thread message queue before signalling Started, IsResponsiveAsync probe still no-op-round-trips through PostThreadMessage so the wedge detection works against the real pump. Concurrent ConcurrentQueue<WorkItem> drains on every WM_APP; fault path on dispose drains-and-faults all pending work-item TCSes with InvalidOperationException("STA pump has exited"). All three StaPumpTests pass against the real pump (apartment state STA, healthy probe true, wedged probe false). GalaxyProxyDriver now implements every Phase 2 Stream C capability — IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe — each forwarding through the matching IPC contract. ReadAsync preserves request order even when the Host returns out-of-order values; WriteAsync MessagePack-serializes the value into ValueBytes; SubscribeAsync wraps SubscriptionId in a GalaxySubscriptionHandle record; UnsubscribeAsync uses the new SendOneWayAsync helper on GalaxyIpcClient (fire-and-forget but still gated through the call-semaphore so it doesn't interleave with CallAsync); AlarmSubscribe is one-way and the Host pushes events back via OnAlarmEvent; ReadProcessedAsync short-circuits to NotSupportedException (Galaxy historian only does raw); IRediscoverable's OnRediscoveryNeeded fires when the Host pushes a deploy-watermark notification; IHostConnectivityProbe.GetHostStatuses() snapshots and OnHostStatusChanged fires on Running↔Stopped/Faulted transitions, with IpcHostConnectivityStatus aliased to disambiguate from the Core.Abstractions namespace's same-named type. Internal RaiseDataChange/RaiseAlarmEvent/RaiseRediscoveryNeeded/OnHostConnectivityUpdate methods are the entry points the IPC client will invoke when push frames arrive. Host side: new Backend/IGalaxyBackend interface defines the seam between IPC dispatch and the live MXAccess code (so the dispatcher is unit-testable against an in-memory mock without needing live Galaxy); Backend/StubGalaxyBackend returns success for OpenSession/CloseSession/Subscribe/Unsubscribe/AlarmSubscribe/AlarmAck/Recycle and a recognizable "stub: MXAccess code lift pending (Phase 2 Task B.1)"-tagged error for Discover/ReadValues/WriteValues/HistoryRead — keeps the IPC end-to-end testable today and gives the parity team a clear seam to slot the real implementation into; Ipc/GalaxyFrameHandler is the new real dispatcher (replaces StubFrameHandler in Program.cs) — switch on MessageKind, deserialize the matching contract, await backend method, write the response (one-way for Unsubscribe/AlarmSubscribe/AlarmAck/CloseSession), heartbeat handled inline so liveness still works if the backend is sick, exceptions caught and surfaced as ErrorResponse with code "handler-exception" so the Proxy raises GalaxyIpcException instead of disconnecting. End-to-end IPC integration test (EndToEndIpcTests) drives every operation through the full stack — Initialize → Read → Write → Subscribe → Unsubscribe → SubscribeAlarms → AlarmAck → ReadRaw → ReadProcessed (short-circuit) — proving the wire protocol, dispatcher, capability forwarding, and one-way semantics agree end-to-end. Skipped on Windows administrator shells per the same PipeAcl-denies-Administrators reasoning the IpcHandshakeIntegrationTests use. Full solution 952 pass / 1 pre-existing Phase 0 baseline. Phase 2 evidence doc updated: status header now reads "Streams A+B+C complete... Streams D+E remain — gated only on the iterative Galaxy code lift + parity-debug cycle"; new Update 2026-04-17 (later) callout enumerates the upgrade with explicit "what's left for the Phase 2 exit gate" — replace StubGalaxyBackend with a MxAccessClient-backed implementation calling on the StaPump, then run the v1 IntegrationTests against the v2 topology and iterate on parity defects until green, then delete legacy OtOpcUa.Host.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-17 23:02:00 -04:00
..
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 2 Streams A+B+C feature-complete — real Win32 pump, all 9 IDriver capabilities, end-to-end IPC dispatch. Streams D+E remain (Galaxy MXAccess code lift + parity-debug cycle, plan-budgeted 3-4 weeks). The 494 v1 IntegrationTests still pass — legacy OtOpcUa.Host untouched. StaPump replaces the BlockingCollection placeholder with a real Win32 message pump lifted from v1 StaComThread per CLAUDE.md "Reference Implementation": dedicated STA Thread with SetApartmentState(STA), GetMessage/PostThreadMessage/PeekMessage/TranslateMessage/DispatchMessage/PostQuitMessage P/Invoke, WM_APP=0x8000 for work-item dispatch, WM_APP+1 for graceful-drain → PostQuitMessage, peek-pm-noremove on entry to force the system to create the thread message queue before signalling Started, IsResponsiveAsync probe still no-op-round-trips through PostThreadMessage so the wedge detection works against the real pump. Concurrent ConcurrentQueue<WorkItem> drains on every WM_APP; fault path on dispose drains-and-faults all pending work-item TCSes with InvalidOperationException("STA pump has exited"). All three StaPumpTests pass against the real pump (apartment state STA, healthy probe true, wedged probe false). GalaxyProxyDriver now implements every Phase 2 Stream C capability — IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IRediscoverable, IHostConnectivityProbe — each forwarding through the matching IPC contract. ReadAsync preserves request order even when the Host returns out-of-order values; WriteAsync MessagePack-serializes the value into ValueBytes; SubscribeAsync wraps SubscriptionId in a GalaxySubscriptionHandle record; UnsubscribeAsync uses the new SendOneWayAsync helper on GalaxyIpcClient (fire-and-forget but still gated through the call-semaphore so it doesn't interleave with CallAsync); AlarmSubscribe is one-way and the Host pushes events back via OnAlarmEvent; ReadProcessedAsync short-circuits to NotSupportedException (Galaxy historian only does raw); IRediscoverable's OnRediscoveryNeeded fires when the Host pushes a deploy-watermark notification; IHostConnectivityProbe.GetHostStatuses() snapshots and OnHostStatusChanged fires on Running↔Stopped/Faulted transitions, with IpcHostConnectivityStatus aliased to disambiguate from the Core.Abstractions namespace's same-named type. Internal RaiseDataChange/RaiseAlarmEvent/RaiseRediscoveryNeeded/OnHostConnectivityUpdate methods are the entry points the IPC client will invoke when push frames arrive. Host side: new Backend/IGalaxyBackend interface defines the seam between IPC dispatch and the live MXAccess code (so the dispatcher is unit-testable against an in-memory mock without needing live Galaxy); Backend/StubGalaxyBackend returns success for OpenSession/CloseSession/Subscribe/Unsubscribe/AlarmSubscribe/AlarmAck/Recycle and a recognizable "stub: MXAccess code lift pending (Phase 2 Task B.1)"-tagged error for Discover/ReadValues/WriteValues/HistoryRead — keeps the IPC end-to-end testable today and gives the parity team a clear seam to slot the real implementation into; Ipc/GalaxyFrameHandler is the new real dispatcher (replaces StubFrameHandler in Program.cs) — switch on MessageKind, deserialize the matching contract, await backend method, write the response (one-way for Unsubscribe/AlarmSubscribe/AlarmAck/CloseSession), heartbeat handled inline so liveness still works if the backend is sick, exceptions caught and surfaced as ErrorResponse with code "handler-exception" so the Proxy raises GalaxyIpcException instead of disconnecting. End-to-end IPC integration test (EndToEndIpcTests) drives every operation through the full stack — Initialize → Read → Write → Subscribe → Unsubscribe → SubscribeAlarms → AlarmAck → ReadRaw → ReadProcessed (short-circuit) — proving the wire protocol, dispatcher, capability forwarding, and one-way semantics agree end-to-end. Skipped on Windows administrator shells per the same PipeAcl-denies-Administrators reasoning the IpcHandshakeIntegrationTests use. Full solution 952 pass / 1 pre-existing Phase 0 baseline. Phase 2 evidence doc updated: status header now reads "Streams A+B+C complete... Streams D+E remain — gated only on the iterative Galaxy code lift + parity-debug cycle"; new Update 2026-04-17 (later) callout enumerates the upgrade with explicit "what's left for the Phase 2 exit gate" — replace StubGalaxyBackend with a MxAccessClient-backed implementation calling on the StaPump, then run the v1 IntegrationTests against the v2 topology and iterate on parity defects until green, then delete legacy OtOpcUa.Host.
2026-04-17 23:02:00 -04:00