Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests/OpcPlcFixture.cs
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00

98 lines
4.4 KiB
C#

using System.Net.Sockets;
namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
/// <summary>
/// Reachability probe for an <c>opc-plc</c> simulator (Microsoft Industrial IoT's
/// OPC UA PLC from <c>mcr.microsoft.com/iotedge/opc-plc</c>) or any real OPC UA
/// server the <c>OPCUA_SIM_ENDPOINT</c> env var points at. Parses
/// <c>OPCUA_SIM_ENDPOINT</c> (default <c>opc.tcp://localhost:50000</c>),
/// TCP-connects to the resolved host:port at collection init, and records a
/// <see cref="SkipReason"/> on failure. Tests call <c>Assert.Skip</c> on that, so
/// `dotnet test` stays green when Docker isn't running the simulator — mirrors the
/// <see cref="ModbusSimulatorFixture"/> / <c>Snap7ServerFixture</c> pattern.
/// </summary>
/// <remarks>
/// <para>
/// <b>Why opc-plc over loopback against our own server</b> — (1) independent
/// cert chain + user-token handling catches interop bugs loopback can't;
/// (2) built-in alarm ConditionType + history simulation gives
/// <see cref="Core.Abstractions.IAlarmSource"/> +
/// <see cref="Core.Abstractions.IHistoryProvider"/> coverage without a custom
/// driver fake; (3) pinned image tag fixes the test surface in a way our own
/// evolving server wouldn't. Follow-up: add <c>open62541/open62541</c> as a
/// second image once this lands, for fully-independent-stack interop.
/// </para>
/// <para>
/// Endpoint URL contract: parser strips the <c>opc.tcp://</c> scheme + resolves
/// host + port for the liveness probe only. The real test session always
/// dials the full endpoint URL via <see cref="OpcUaClientDriverOptions.EndpointUrl"/>
/// so cert negotiation + security-policy selection run end-to-end.
/// </para>
/// </remarks>
public sealed class OpcPlcFixture : IAsyncDisposable
{
private const string DefaultEndpoint = "opc.tcp://localhost:50000";
private const string EndpointEnvVar = "OPCUA_SIM_ENDPOINT";
/// <summary>Full <c>opc.tcp://host:port</c> URL the driver session should connect to.</summary>
public string EndpointUrl { get; }
public string Host { get; }
public int Port { get; }
public string? SkipReason { get; }
public OpcPlcFixture()
{
EndpointUrl = Environment.GetEnvironmentVariable(EndpointEnvVar) ?? DefaultEndpoint;
(Host, Port) = ParseHostPort(EndpointUrl);
try
{
using var client = new TcpClient(AddressFamily.InterNetwork);
var task = client.ConnectAsync(
System.Net.Dns.GetHostAddresses(Host)
.FirstOrDefault(a => a.AddressFamily == AddressFamily.InterNetwork)
?? System.Net.IPAddress.Loopback,
Port);
if (!task.Wait(TimeSpan.FromSeconds(2)) || !client.Connected)
{
SkipReason = $"opc-plc simulator at {Host}:{Port} did not accept a TCP connection within 2s. " +
$"Start it (`docker compose -f Docker/docker-compose.yml up`) or override {EndpointEnvVar}.";
}
}
catch (Exception ex)
{
SkipReason = $"opc-plc simulator at {Host}:{Port} unreachable: {ex.GetType().Name}: {ex.Message}. " +
$"Start it (`docker compose -f Docker/docker-compose.yml up`) or override {EndpointEnvVar}.";
}
}
/// <summary>
/// Parse "opc.tcp://host:port[/path]" → (host, port). Defaults to port 4840
/// (OPC UA standard) when the URL omits the port, but opc-plc's default is
/// 50000 so DefaultEndpoint carries it explicitly.
/// </summary>
private static (string Host, int Port) ParseHostPort(string endpointUrl)
{
const string scheme = "opc.tcp://";
var body = endpointUrl.StartsWith(scheme, StringComparison.OrdinalIgnoreCase)
? endpointUrl[scheme.Length..]
: endpointUrl;
var slash = body.IndexOf('/');
if (slash >= 0) body = body[..slash];
var colon = body.IndexOf(':');
if (colon < 0) return (body, 4840);
var host = body[..colon];
return int.TryParse(body[(colon + 1)..], out var p) ? (host, p) : (host, 4840);
}
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
}
[Xunit.CollectionDefinition(Name)]
public sealed class OpcPlcCollection : Xunit.ICollectionFixture<OpcPlcFixture>
{
public const string Name = "OpcPlc";
}