namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip;
/// <summary>
/// Thin wire-layer abstraction over a single CIP tag. The driver holds one instance per
/// <c>(device, tag path)</c> pair; the default implementation delegates to
/// <see cref="LibplctagTagRuntime"/>. Tests swap in a fake via
/// <see cref="IAbCipTagFactory"/> so the driver's read / write / status-mapping logic can
/// be exercised without a running PLC or the native libplctag binary.
/// </summary>
public interface IAbCipTagRuntime : IDisposable
{
/// <summary>Create the underlying native tag (equivalent to libplctag's <c>plc_tag_create</c>).</summary>
Task InitializeAsync(CancellationToken cancellationToken);
/// <summary>Issue a read; on completion the local buffer holds the current PLC value.</summary>
Task ReadAsync(CancellationToken cancellationToken);
/// <summary>Flush the local buffer to the PLC.</summary>
Task WriteAsync(CancellationToken cancellationToken);
/// <summary>
/// Raw libplctag status code — mapped to an OPC UA StatusCode via
/// <see cref="AbCipStatusMapper.MapLibplctagStatus"/>. Zero on success, negative on error.
/// </summary>
int GetStatus();
/// <summary>
/// Decode the local buffer into a boxed .NET value per the tag's configured type.
/// <paramref name="bitIndex"/> is non-null only for BOOL-within-DINT tags captured in
/// the <c>.N</c> syntax at parse time.
/// </summary>
object? DecodeValue(AbCipDataType type, int? bitIndex);
/// <summary>
/// Decode a value at an arbitrary byte offset in the local buffer. Task #194 —
/// whole-UDT reads perform one <see cref="ReadAsync"/> on the parent UDT tag then
/// call this per declared member with its computed offset, avoiding one libplctag
/// round-trip per member. Implementations that do not support offset-aware decoding
/// may fall back to <see cref="DecodeValue"/> when <paramref name="offset"/> is zero;
/// offsets greater than zero against an unsupporting runtime should return <c>null</c>
/// so the planner can skip grouping.
/// </summary>
object? DecodeValueAt(AbCipDataType type, int offset, int? bitIndex);
/// <summary>
/// Encode <paramref name="value"/> into the local buffer per the tag's type. Callers
/// pair this with <see cref="WriteAsync"/>.
/// </summary>
void EncodeValue(AbCipDataType type, int? bitIndex, object? value);
}
/// <summary>
/// Factory for per-tag runtime handles. Instantiated once per driver, consumed per
/// <c>(device, tag path)</c> pair at the first read/write.
/// </summary>
public interface IAbCipTagFactory
{
IAbCipTagRuntime Create(AbCipTagCreateParams createParams);
}
/// <summary>Everything libplctag needs to materialise a tag handle.</summary>
/// <param name="Gateway">Gateway IP / hostname parsed from <see cref="AbCipHostAddress.Gateway"/>.</param>
/// <param name="Port">EtherNet/IP TCP port — default 44818.</param>
/// <param name="CipPath">CIP route path, e.g. <c>1,0</c>. Empty for Micro800.</param>
/// <param name="LibplctagPlcAttribute">libplctag <c>plc=...</c> attribute, per family profile.</param>
/// <param name="TagName">Logix symbolic tag name as emitted by <see cref="AbCipTagPath.ToLibplctagName"/>.</param>
/// <param name="Timeout">libplctag operation timeout (applies to Initialize / Read / Write).</param>
/// <param name="StringMaxCapacity">Optional Logix STRINGnn DATA-array capacity (e.g. 20 / 40 / 80
/// for <c>STRING_20</c> / <c>STRING_40</c> / <c>STRING_80</c> UDTs). Threads through libplctag's
/// <c>str_max_capacity</c> attribute. <c>null</c> keeps libplctag's default 82-byte STRING
/// behaviour for back-compat.</param>
/// <param name="ElementCount">Optional libplctag <c>ElementCount</c> override — set to <c>N</c>
/// to issue a Rockwell array read covering <c>N</c> consecutive elements starting at the
/// subscripted index in <see cref="TagName"/>. Drives PR abcip-1.3 array-slice support;
/// <c>null</c> leaves libplctag's default scalar-element behaviour for back-compat.</param>
/// <param name="ConnectionSize">PR abcip-3.1 — CIP Forward Open buffer size in bytes. Threads
/// through to libplctag's <c>connection_size</c> attribute. The driver always supplies a
/// value here — either the per-device <see cref="AbCipDeviceOptions.ConnectionSize"/>
/// override or the family profile's <see cref="PlcFamilies.AbCipPlcFamilyProfile.DefaultConnectionSize"/>.
/// Bigger packets fit more tags per RTT (higher throughput); smaller packets stay compatible
/// with legacy firmware (v19-and-earlier ControlLogix caps at 504, Micro800 hard-caps at
/// 488).</param>
/// <param name="AddressingMode">PR abcip-3.2 — concrete addressing mode the runtime should
/// activate for this tag handle. Always either <see cref="AddressingMode.Symbolic"/> or
/// <see cref="AddressingMode.Logical"/> at this layer (the driver resolves <c>Auto</c> +
/// family-incompatibility before building the create-params). Symbolic is the libplctag
/// default and needs no extra attribute. Logical adds the libplctag <c>use_connected_msg=1</c>
/// attribute + (when an instance ID is known via <see cref="LogicalInstanceId"/>) reaches
/// into <c>NativeTagWrapper.SetAttributeString</c> by reflection because the .NET wrapper
/// does not expose a public knob for instance-ID addressing.</param>
/// <param name="LogicalInstanceId">PR abcip-3.2 — Symbol Object instance ID the controller
/// assigned to this tag, populated by the driver after a one-time <c>@tags</c> walk for
/// Logical-mode devices. <c>null</c> for Symbolic mode + for the very first read on a
/// Logical device when the symbol-table walk has not yet completed; the runtime falls back
/// to Symbolic addressing in either case so the read still completes.</param>
public sealed record AbCipTagCreateParams(
string Gateway,
int Port,
string CipPath,
string LibplctagPlcAttribute,
string TagName,
TimeSpan Timeout,
int? StringMaxCapacity = null,
int? ElementCount = null,
int ConnectionSize = 4002,
AddressingMode AddressingMode = AddressingMode.Symbolic,
uint? LogicalInstanceId = null);