Joseph Doherty 2b5222f5db Phase 3 PR 47 -- DL205 V-memory octal-address helper. Adds DirectLogicAddress static class with two entry points: UserVMemoryToPdu(string) parses a DirectLOGIC V-address (V-prefixed or bare, whitespace tolerated) as OCTAL and returns the 0-based Modbus PDU address. V2000 octal = decimal 1024 = PDU 0x0400, which is the canonical start of the user V-memory bank on DL205/DL260. SystemVMemoryBasePdu + SystemVMemoryToPdu(ushort offset) handle the system bank (V40400 and up) which does NOT follow the simple octal-to-decimal formula -- the CPU relocates the system bank to PDU 0x2100 in H2-ECOM100 absolute mode. A naive caller converting 40400 octal would land at PDU 0x4100 (decimal 16640) and miss the system registers entirely; the helper routes the correct 0x2100 base. Why this matters: DirectLOGIC operators think in OCTAL (the ladder-logic editor, the Productivity/Do-more UI, every AutomationDirect manual addresses V-memory octally) while the Modbus wire is DECIMAL. Integrators routinely copy V-addresses from the PLC documentation into client configs and read garbage because they treated V2000 as decimal 2000 (HR[2000] = 0 in the dl205 sim, zero in most PLCs). The helper makes the translation explicit per the D2-USER-M appendix + H2-ECOM-M \u00A76.5 references cited in docs/v2/dl205.md. Unit tests: UserVMemoryToPdu_converts_octal_V_prefix (V0, V1, V7, V10, V2000, V7777, V10000, V17777 -- the exact sweep documented in dl205.md), UserVMemoryToPdu_accepts_bare_or_prefixed_or_padded (case + whitespace tolerance), UserVMemoryToPdu_rejects_non_octal_digits (V8/V19/V2009 must throw ArgumentException with 'octal' in the message -- .NET has no base-8 int.Parse so we hand-walk digits to catch 8/9 instead of silently accepting them), UserVMemoryToPdu_rejects_empty_input, UserVMemoryToPdu_overflow_rejected (200000 octal = 0x10000 overflows ushort), SystemVMemoryBasePdu_is_0x2100_for_V40400, SystemVMemoryToPdu_offsets_within_bank, SystemVMemoryToPdu_rejects_overflow. 23/23 Modbus.Tests pass. Integration tests against dl205.json pymodbus profile: DL205_V2000_user_memory_resolves_to_PDU_0x0400_marker (reads HR[0x0400]=0x2000), DL205_V40400_system_memory_resolves_to_PDU_0x2100_marker (reads HR[0x2100]=0x4040). 5/5 DL205 integration tests pass. Caller opts into the helper per tag by calling DirectLogicAddress.UserVMemoryToPdu("V2000") as the ModbusTagDefinition Address -- no driver-wide "DL205 mode" flag needed, because users mix DL and non-DL tags in a single driver instance all the time.
2026-04-18 21:49:58 -04:00
..
Phase 3 PR 47 -- DL205 V-memory octal-address helper. Adds DirectLogicAddress static class with two entry points: UserVMemoryToPdu(string) parses a DirectLOGIC V-address (V-prefixed or bare, whitespace tolerated) as OCTAL and returns the 0-based Modbus PDU address. V2000 octal = decimal 1024 = PDU 0x0400, which is the canonical start of the user V-memory bank on DL205/DL260. SystemVMemoryBasePdu + SystemVMemoryToPdu(ushort offset) handle the system bank (V40400 and up) which does NOT follow the simple octal-to-decimal formula -- the CPU relocates the system bank to PDU 0x2100 in H2-ECOM100 absolute mode. A naive caller converting 40400 octal would land at PDU 0x4100 (decimal 16640) and miss the system registers entirely; the helper routes the correct 0x2100 base. Why this matters: DirectLOGIC operators think in OCTAL (the ladder-logic editor, the Productivity/Do-more UI, every AutomationDirect manual addresses V-memory octally) while the Modbus wire is DECIMAL. Integrators routinely copy V-addresses from the PLC documentation into client configs and read garbage because they treated V2000 as decimal 2000 (HR[2000] = 0 in the dl205 sim, zero in most PLCs). The helper makes the translation explicit per the D2-USER-M appendix + H2-ECOM-M \u00A76.5 references cited in docs/v2/dl205.md. Unit tests: UserVMemoryToPdu_converts_octal_V_prefix (V0, V1, V7, V10, V2000, V7777, V10000, V17777 -- the exact sweep documented in dl205.md), UserVMemoryToPdu_accepts_bare_or_prefixed_or_padded (case + whitespace tolerance), UserVMemoryToPdu_rejects_non_octal_digits (V8/V19/V2009 must throw ArgumentException with 'octal' in the message -- .NET has no base-8 int.Parse so we hand-walk digits to catch 8/9 instead of silently accepting them), UserVMemoryToPdu_rejects_empty_input, UserVMemoryToPdu_overflow_rejected (200000 octal = 0x10000 overflows ushort), SystemVMemoryBasePdu_is_0x2100_for_V40400, SystemVMemoryToPdu_offsets_within_bank, SystemVMemoryToPdu_rejects_overflow. 23/23 Modbus.Tests pass. Integration tests against dl205.json pymodbus profile: DL205_V2000_user_memory_resolves_to_PDU_0x0400_marker (reads HR[0x0400]=0x2000), DL205_V40400_system_memory_resolves_to_PDU_0x2100_marker (reads HR[0x2100]=0x4040). 5/5 DL205 integration tests pass. Caller opts into the helper per tag by calling DirectLogicAddress.UserVMemoryToPdu("V2000") as the ModbusTagDefinition Address -- no driver-wide "DL205 mode" flag needed, because users mix DL and non-DL tags in a single driver instance all the time.
2026-04-18 21:49:58 -04:00
Phase 3 PR 46 -- DL205 BCD decoder (binary-coded-decimal numeric encoding). Adds ModbusDataType.Bcd16 and Bcd32 to the driver. Bcd16 is 1 register wide, Bcd32 is 2 registers wide; Bcd32 respects ModbusByteOrder (BigEndian/WordSwap) the same way Int32 does so the CDAB-style families (including DL205/DL260 themselves) can be configured. DecodeRegister uses the new internal DecodeBcd helper: walks each nibble from MSB to LSB, multiplies the running result by 10, adds the nibble as a decimal digit. Explicitly rejects nibbles > 9 with InvalidDataException -- hardware sometimes produces garbage during write-in-progress transitions and silently returning wrong numeric values would quietly corrupt the caller's data. EncodeRegister's new EncodeBcd inverts the operation (mod/div by 10 nibble-by-nibble) with an up-front overflow check against 10^nibbles-1. Why this matters for DL205/DL260: AutomationDirect DirectLOGIC uses BCD as the default numeric encoding for timers, counters, and operator-display numerics (not binary). A plain Int16 read of register 0x1234 returns 4660; the BCD path returns 1234. The two differ enough that silently defaulting to Int16 would give wildly wrong HMI values -- the caller must opt in to Bcd16/Bcd32 per tag. Unit tests: DecodeBcd (theory: 0,1,9,10,1234,9999), DecodeBcd_rejects_nibbles_above_nine, EncodeBcd (theory), Bcd16_decodes_DL205_register_1234_as_decimal_1234 (control: same bytes as Int16 decode to 4660), Bcd16_encode_round_trips_with_decode, Bcd16_encode_rejects_out_of_range_values, Bcd32_decodes_8_digits_big_endian, Bcd32_word_swap_handles_CDAB_layout, Bcd32_encode_round_trips_with_decode, Bcd_RegisterCount_matches_underlying_width. 66/66 Modbus.Tests pass. Integration test: DL205BcdQuirkTests.DL205_BCD16_decodes_HR1072_as_decimal_1234 against dl205.json pymodbus profile (HR[1072]=0x1234). Asserts Bcd16 decode=1234 AND Int16 decode=0x1234 on the same wire bytes to prove the paths are distinct. 3/3 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:46:25 -04:00
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
2026-04-18 11:55:21 -04:00
Phase 3 PR 23 — Modbus IHostConnectivityProbe. ModbusDriver now implements 6 of 8 capability interfaces (adds IHostConnectivityProbe alongside IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable from the earlier PRs). Background probe loop kicks off in InitializeAsync when ModbusProbeOptions.Enabled is true, sends a cheap FC03 read-1-register at ProbeAddress (default 0) every Interval (default 5s) with a per-tick Timeout (default 2s), and tracks the single Modbus endpoint's state in the HostState machine. Initial state = Unknown; first successful probe transitions to Running; any transport/timeout failure transitions to Stopped; recovery transitions back to Running. OnHostStatusChanged fires exactly on transitions (not on repeat successes — prevents event-spam on a healthy connection). HostName format is 'host:port' so the Admin UI can display the endpoint uniformly with Galaxy platforms/engines in the fleet status dashboard. GetHostStatuses returns a single-item list with the current state + last-change timestamp (Modbus driver talks to exactly one endpoint per instance — operators spin up multiple driver instances for multi-PLC deployments). ShutdownAsync cancels the probe CTS before tearing down the transport so the loop can't log a spurious Stopped after intentional shutdown (OperationCanceledException caught separately from the 'real' transport errors). ModbusDriverOptions extended with ModbusProbeOptions sub-record (Enabled default true, Interval 5s, Timeout 2s, ProbeAddress ushort for PLCs that have register-0 policies; most PLCs tolerate an FC03 at 0 but some industrial gateways lock it). Tests (7 new ModbusProbeTests): Initial_state_is_Unknown_before_first_probe_tick (probe disabled, state stays Unknown, HostName formatted); First_successful_probe_transitions_to_Running (enabled, waits for probe count + event queue, asserts Unknown → Running with correct OldState/NewState); Transport_failure_transitions_to_Stopped (flip fake.Reachable = false mid-run, wait for state diff); Recovery_transitions_Stopped_back_to_Running (up → down → up, asserts ≥ 3 transitions); Repeated_successful_probes_do_not_generate_duplicate_Running_events (several hundred ms of stable probes, count stays at 1); Disabled_probe_stays_Unknown_and_fires_no_events (safety guard when operator wants to disable probing); Shutdown_stops_the_probe_loop (probe count captured at shutdown, delay 400ms, assert ≤ 1 extra to tolerate the narrow race where an in-flight tick completes after shutdown — the contract is 'no new ticks scheduled' not 'instantaneous freeze'). FlappyTransport fake exposes a volatile Reachable flag so tests can toggle the PLC availability mid-run, + ProbeCount counter so tests can assert the loop actually issued requests. WaitForStateAsync helper polls GetHostStatuses up to a deadline; tolerates scheduler jitter on slow CI runners. Full solution: 0 errors, 202 unit + integration tests pass (22 Modbus + 180 pre-existing).
2026-04-18 12:12:00 -04:00
Phase 3 PR 22 — Modbus ISubscribable via polling overlay. Modbus has no push model at the wire protocol (unlike MXAccess's OnDataChange callback or OPC UA's own Subscription service), so the driver layers a per-subscription polling loop on top of the existing IReadable path: SubscribeAsync returns an opaque ModbusSubscriptionHandle, starts a background Task.Run that sleeps for the requested publishing interval (floored to 100ms so a misconfigured sub-10ms request doesn't hammer the PLC), reads every subscribed tag through the same FC01/03/04 path the one-shot ReadAsync uses, diffs the returned DataValueSnapshot against the last known value per tag, and raises OnDataChange exactly when (a) it's the first poll (initial-data push per OPC UA Part 4 convention) or (b) boxed value changed or (c) StatusCode changed — stable values don't generate event traffic after the initial push, matching the v1 MXAccess OnDataChange shape. SubscriptionState record holds the handle + tag list + interval + per-subscription CancellationTokenSource + ConcurrentDictionary<string,DataValueSnapshot> LastValues; UnsubscribeAsync removes the state from _subscriptions and cancels the CTS, stopping the polling loop cleanly. Multiple overlapping subscriptions each get their own polling Task so a slow PLC on one subscription can't stall the others. ShutdownAsync cancels every active subscription CTS before tearing down the transport so the driver doesn't leave orphaned polling tasks pumping requests against a disposed socket. Transient poll errors are swallowed inside the loop (the loop continues to the next tick) — the driver's health surface reflects the last-known Degraded state from the underlying ReadAsync path. OperationCanceledException is caught separately to exit the loop silently on unsubscribe/shutdown. Tests (6 new ModbusSubscriptionTests): Initial_poll_raises_OnDataChange_for_every_subscribed_tag asserts the initial-data push fires once per tag in the subscribe call (2 tags → 2 events with FullReference='Level' and FullReference='Temp'); Unchanged_values_do_not_raise_after_initial_poll lets the loop run ~5 cycles at 100ms with a stable register value, asserts only the initial push fires (no event spam on stable tags); Value_change_between_polls_raises_OnDataChange mutates the fake register bank between poll ticks and asserts a second event fires with the new value (verified via e.Snapshot.Value.ShouldBe((short)200)); Unsubscribe_stops_the_polling_loop captures the event count right after UnsubscribeAsync, mutates a register that would have triggered a change if polling continued, asserts the count stays the same after 400ms; SubscribeAsync_floors_intervals_below_100ms passes a 10ms interval + asserts only 1 event fires across 300ms (if the floor weren't enforced we'd see 30 — the test asserts the floor semantically by counting events on stable data); Multiple_subscriptions_fire_independently creates two subs on different tags, unsubscribes only one, mutates the other's tag, asserts only the surviving sub emits while the unsubscribed one stays at its pre-unsubscribe count. FakeTransport in this test file is scoped to FC03 only since that's all the subscription path exercises — keeps the test doubles minimal and the failure modes obvious. WaitForCountAsync helper polls a ConcurrentQueue up to a deadline, makes the tests tolerant of scheduler jitter on slow CI runners. Full solution: 0 errors, 195 tests pass (6 new subscription + 9 existing Modbus + 180 pre-existing). ModbusDriver now implements IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable — five of the eight capability interfaces. IAlarmSource + IHistoryProvider remain unimplemented because Modbus has no wire-level alarm or history semantics; IHostConnectivityProbe is a plausible future addition (treat transport disconnect as a Stopped signal) but needs the socket-level connection-state tracking plumbed through IModbusTransport which is its own PR.
2026-04-18 12:03:39 -04:00
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
2026-04-18 11:55:21 -04:00