lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Client.CLI.Tests/WriteCommandTests.cs
Joseph Doherty 3b2defd94f Phase 0 — mechanical rename ZB.MOM.WW.LmxOpcUa.* → ZB.MOM.WW.OtOpcUa.*
Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.

Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.

Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-17 13:57:47 -04:00

103 lines
3.2 KiB
C#

using Opc.Ua;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Commands;
using ZB.MOM.WW.OtOpcUa.Client.CLI.Tests.Fakes;
namespace ZB.MOM.WW.OtOpcUa.Client.CLI.Tests;
public class WriteCommandTests
{
[Fact]
public async Task Execute_WritesSuccessfully()
{
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(new Variant(42)),
WriteStatusCodeResult = StatusCodes.Good
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new WriteCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=MyVar",
Value = "100"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
var output = TestConsoleHelper.GetOutput(console);
output.ShouldContain("Write successful: ns=2;s=MyVar = 100");
}
[Fact]
public async Task Execute_ReportsFailure()
{
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(new Variant("current")),
WriteStatusCodeResult = StatusCodes.BadNotWritable
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new WriteCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=ReadOnly",
Value = "newvalue"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
var output = TestConsoleHelper.GetOutput(console);
output.ShouldContain("Write failed:");
}
[Fact]
public async Task Execute_ReadsCurrentValueThenWrites()
{
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(new Variant(3.14)),
WriteStatusCodeResult = StatusCodes.Good
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new WriteCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=FloatVar",
Value = "2.718"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
// Should read first to get current type, then write
fakeService.ReadNodeIds.Count.ShouldBe(1);
fakeService.WriteValues.Count.ShouldBe(1);
fakeService.WriteValues[0].Value.ShouldBeOfType<double>();
}
[Fact]
public async Task Execute_DisconnectsInFinally()
{
var fakeService = new FakeOpcUaClientService
{
ReadValueResult = new DataValue(new Variant("test"))
};
var factory = new FakeOpcUaClientServiceFactory(fakeService);
var command = new WriteCommand(factory)
{
Url = "opc.tcp://localhost:4840",
NodeId = "ns=2;s=Node",
Value = "value"
};
using var console = TestConsoleHelper.CreateConsole();
await command.ExecuteAsync(console);
fakeService.DisconnectCalled.ShouldBeTrue();
fakeService.DisposeCalled.ShouldBeTrue();
}
}