Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient
Joseph Doherty c9e856178a Phase 3 PR 76 -- OPC UA Client IHistoryProvider (HistoryRead passthrough). Driver now implements IHistoryProvider (Raw + Processed + AtTime); ReadEventsAsync deliberately inherits the interface default that throws NotSupportedException. ExecuteHistoryReadAsync is the shared wire path: parses the fullReference to NodeId, builds a HistoryReadValueIdCollection with one entry, calls Session.HistoryReadAsync(RequestHeader, ExtensionObject<details>, TimestampsToReturn.Both, releaseContinuationPoints:false, nodesToRead, ct), unwraps r.HistoryData ExtensionObject into the samples list, passes ContinuationPoint through. Each DataValue's upstream StatusCode + SourceTimestamp + ServerTimestamp preserved verbatim per driver-specs.md \u00A78 cascading-quality rule -- this matters especially for historical data where an interpolated / uncertain-quality sample must surface its true severity downstream, not a sanitized Good. SourceTimestamp=DateTime.MinValue guards map to null so downstream clients see 'source unknown' rather than an epoch-zero misread. ReadRawAsync builds ReadRawModifiedDetails with IsReadModified=false (raw, not modified-history), StartTime/EndTime, NumValuesPerNode=maxValuesPerNode, ReturnBounds=false (clients that want bounds request them via continuation handling). ReadProcessedAsync builds ReadProcessedDetails with ProcessingInterval in ms + AggregateType wrapping a single NodeId from MapAggregateToNodeId. MapAggregateToNodeId switches on HistoryAggregateType {Average, Minimum, Maximum, Total, Count} to the standard Part 13 ObjectIds.AggregateFunction_* NodeId -- future aggregate-type additions fail the switch with ArgumentOutOfRangeException so they can't silently slip through with a null NodeId and an opaque server-side BadAggregateNotSupported. ReadAtTimeAsync builds ReadAtTimeDetails with ReqTimes + UseSimpleBounds=true (returns boundary samples when an exact timestamp has no value -- the OPC UA Part 11 default). Malformed NodeId short-circuits to empty result without touching the wire, matching the ReadAsync / WriteAsync pattern. ReadEventsAsync stays at the interface-default NotSupportedException: the OPC UA call path (HistoryReadAsync with ReadEventDetails + EventFilter) needs an EventFilter SelectClauses spec which the current IHistoryProvider.ReadEventsAsync signature doesn't carry. Adding that would be an IHistoryProvider interface widening; out of scope for PR 76. Callers see BadHistoryOperationUnsupported on the OPC UA client which is the documented fallback. Name disambiguation: Core.Abstractions.HistoryReadResult and Opc.Ua.HistoryReadResult both exist; used fully-qualified Core.Abstractions.HistoryReadResult in return types + factory expressions. Shutdown unchanged -- history reads don't create persistent server-side resources, so no cleanup needed beyond the existing Session.CloseAsync. Unit tests (OpcUaClientHistoryTests, 7 facts): MapAggregateToNodeId theory covers all 5 aggregates; MapAggregateToNodeId_rejects_invalid_enum (defense against future enum addition silently passing through); Read{Raw,Processed,AtTime}Async_without_initialize_throws (RequireSession path); ReadEventsAsync_throws_NotSupportedException (locks in the intentional inheritance of the default). 78/78 OpcUaClient.Tests pass (67 prior + 11 new, -4 on the alarm suite moved into the events count). dotnet build clean. Final OPC UA Client capability surface: IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable + IHostConnectivityProbe + IAlarmSource + IHistoryProvider -- 8 of 8 possible capabilities. Driver is feature-complete per driver-specs.md \u00A78.
2026-04-19 02:13:22 -04:00
..
Phase 3 PR 76 -- OPC UA Client IHistoryProvider (HistoryRead passthrough). Driver now implements IHistoryProvider (Raw + Processed + AtTime); ReadEventsAsync deliberately inherits the interface default that throws NotSupportedException. ExecuteHistoryReadAsync is the shared wire path: parses the fullReference to NodeId, builds a HistoryReadValueIdCollection with one entry, calls Session.HistoryReadAsync(RequestHeader, ExtensionObject<details>, TimestampsToReturn.Both, releaseContinuationPoints:false, nodesToRead, ct), unwraps r.HistoryData ExtensionObject into the samples list, passes ContinuationPoint through. Each DataValue's upstream StatusCode + SourceTimestamp + ServerTimestamp preserved verbatim per driver-specs.md \u00A78 cascading-quality rule -- this matters especially for historical data where an interpolated / uncertain-quality sample must surface its true severity downstream, not a sanitized Good. SourceTimestamp=DateTime.MinValue guards map to null so downstream clients see 'source unknown' rather than an epoch-zero misread. ReadRawAsync builds ReadRawModifiedDetails with IsReadModified=false (raw, not modified-history), StartTime/EndTime, NumValuesPerNode=maxValuesPerNode, ReturnBounds=false (clients that want bounds request them via continuation handling). ReadProcessedAsync builds ReadProcessedDetails with ProcessingInterval in ms + AggregateType wrapping a single NodeId from MapAggregateToNodeId. MapAggregateToNodeId switches on HistoryAggregateType {Average, Minimum, Maximum, Total, Count} to the standard Part 13 ObjectIds.AggregateFunction_* NodeId -- future aggregate-type additions fail the switch with ArgumentOutOfRangeException so they can't silently slip through with a null NodeId and an opaque server-side BadAggregateNotSupported. ReadAtTimeAsync builds ReadAtTimeDetails with ReqTimes + UseSimpleBounds=true (returns boundary samples when an exact timestamp has no value -- the OPC UA Part 11 default). Malformed NodeId short-circuits to empty result without touching the wire, matching the ReadAsync / WriteAsync pattern. ReadEventsAsync stays at the interface-default NotSupportedException: the OPC UA call path (HistoryReadAsync with ReadEventDetails + EventFilter) needs an EventFilter SelectClauses spec which the current IHistoryProvider.ReadEventsAsync signature doesn't carry. Adding that would be an IHistoryProvider interface widening; out of scope for PR 76. Callers see BadHistoryOperationUnsupported on the OPC UA client which is the documented fallback. Name disambiguation: Core.Abstractions.HistoryReadResult and Opc.Ua.HistoryReadResult both exist; used fully-qualified Core.Abstractions.HistoryReadResult in return types + factory expressions. Shutdown unchanged -- history reads don't create persistent server-side resources, so no cleanup needed beyond the existing Session.CloseAsync. Unit tests (OpcUaClientHistoryTests, 7 facts): MapAggregateToNodeId theory covers all 5 aggregates; MapAggregateToNodeId_rejects_invalid_enum (defense against future enum addition silently passing through); Read{Raw,Processed,AtTime}Async_without_initialize_throws (RequireSession path); ReadEventsAsync_throws_NotSupportedException (locks in the intentional inheritance of the default). 78/78 OpcUaClient.Tests pass (67 prior + 11 new, -4 on the alarm suite moved into the events count). dotnet build clean. Final OPC UA Client capability surface: IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable + IHostConnectivityProbe + IAlarmSource + IHistoryProvider -- 8 of 8 possible capabilities. Driver is feature-complete per driver-specs.md \u00A78.
2026-04-19 02:13:22 -04:00
Phase 3 PR 72 -- Multi-endpoint failover for OPC UA Client driver. Adds OpcUaClientDriverOptions.EndpointUrls ordered list + PerEndpointConnectTimeout knob. On InitializeAsync the driver walks the candidate list in order via ResolveEndpointCandidates and returns the session from the first endpoint that successfully connects. Captures per-URL failure reasons in a List<string> and, if every candidate fails, throws AggregateException whose message names every URL + its failure class (e.g. 'opc.tcp://primary:4840 -> TimeoutException: ...'). That's critical diag for field debugging -- without it 'failover picked the wrong one' surfaces as a mystery. Single-URL backwards compat: EndpointUrl field retained as a one-URL shortcut. When EndpointUrls is null or empty the driver falls through to a single-candidate list of [EndpointUrl], so every existing single-endpoint config keeps working without migration. When both are provided, EndpointUrls wins + EndpointUrl is ignored -- documented on the field xml-doc. Per-endpoint connect budget: PerEndpointConnectTimeout (default 3s) caps each attempt so a sweep over several dead servers can't blow the overall init budget. Applied via CancellationTokenSource.CreateLinkedTokenSource + CancelAfter inside OpenSessionOnEndpointAsync (the extracted single-endpoint connect helper) so the cap is independent of the outer Options.Timeout which governs steady-state ops. BuildUserIdentity extracted out of InitializeAsync so the failover loop builds the UserIdentity ONCE and reuses it across every endpoint attempt -- generating it N times would re-unlock the user cert's private key N times, wasteful + keeps the password in memory longer. HostName now reflects the endpoint that actually connected via _connectedEndpointUrl instead of always returning opts.EndpointUrl -- so the Admin /hosts dashboard shows which of the configured endpoints is currently serving traffic (primary vs backup). Falls back to the first candidate pre-connect so the dashboard has a sensible identity before the first connect, and resets to null on ShutdownAsync. Use case: an OPC UA hot-standby server pair (primary 4840 + backup 4841) where either can serve the same address space. Operator configures EndpointUrls=[primary, backup]; driver tries primary first, falls over to backup on primary failure with a clean AggregateException describing both attempts if both are down. Unit tests (OpcUaClientFailoverTests, 5 facts): ResolveEndpointCandidates_prefers_EndpointUrls_when_provided (list trumps single), ResolveEndpointCandidates_falls_back_to_single_EndpointUrl_when_list_empty (legacy config compat), ResolveEndpointCandidates_empty_list_treated_as_fallback (explicit empty list also falls back -- otherwise we'd produce a zero-candidate sweep that throws with nothing tried), HostName_uses_first_candidate_before_connect (dashboard rendering pre-connect), Initialize_against_all_unreachable_endpoints_throws_AggregateException_listing_each (three loopback dead ports, asserts each URL appears in the aggregate message + driver flips to Faulted). 31/31 OpcUaClient.Tests pass. dotnet build clean. OPC UA Client driver security/auth/availability feature set now complete per driver-specs.md \u00A78: policy-filtered endpoint selection (PR 70), Anonymous+Username+Certificate auth (PR 71), multi-endpoint failover (this PR).
2026-04-19 01:52:31 -04:00
Phase 3 PR 66 -- OPC UA Client (gateway) driver project scaffold + IDriver session lifecycle. First driver that CONSUMES OPC UA rather than PUBLISHES it -- connects to a remote server and re-exposes its address space through the local OtOpcUa server per driver-specs.md \u00A78. Uses the same OPCFoundation.NetStandard.Opc.Ua.Client package the existing Client.Shared ships (bumped to 1.5.378.106 to match). Builds its own ApplicationConfiguration (cert stores under %LocalAppData%/OtOpcUa/pki so multiple driver instances in one OtOpcUa server process share a trust anchor) rather than reusing Client.Shared -- Client.Shared is oriented at the interactive CLI with different session-lifetime needs (this driver is always-on, needs keep-alive + session transfer on reconnect + multi-year uptime). Navigated the post-refactor 1.5.378 SDK surface: every Session.Create* static is now [Obsolete] in favour of DefaultSessionFactory; CoreClientUtils.SelectEndpoint got the sync overloads deprecated in favour of SelectEndpointAsync with a required ITelemetryContext parameter. Driver passes telemetry: null! to both SelectEndpointAsync + new DefaultSessionFactory(telemetry: null!) -- the SDK's internal default sink handles null gracefully and plumbing a telemetry context through the driver options surface is out of scope (the driver emits its own logs via the DriverHealth surface anyway). ApplicationInstance default ctor is also obsolete; wrapped in #pragma warning disable CS0618 rather than migrate to the ITelemetryContext overload for the same reason. OpcUaClientDriverOptions models driver-specs.md \u00A78 settings: EndpointUrl (default opc.tcp://localhost:4840 IANA-assigned port), SecurityPolicy/SecurityMode/AuthType enums, Username/Password, SessionTimeout=120s + KeepAliveInterval=5s + ReconnectPeriod=5s (defaults from spec), AutoAcceptCertificates=false (production default; dev turns on for self-signed servers), ApplicationUri + SessionName knobs for certificate SAN matching and remote-server session-list identification. OpcUaClientDriver : IDriver: InitializeAsync builds the ApplicationConfiguration, resolves + creates cert if missing via app.CheckApplicationInstanceCertificatesAsync, selects endpoint via CoreClientUtils.SelectEndpointAsync, builds UserIdentity (Anonymous or Username with UTF-8-encoded password bytes -- the legacy string-password ctor went away; Certificate auth deferred), creates session via DefaultSessionFactory.CreateAsync. Health transitions Unknown -> Initializing -> Healthy on success or -> Faulted on failure with best-effort Session.CloseAsync cleanup. ShutdownAsync (async now, not Task.CompletedTask) closes the session + disposes. Internal Session + Gate expose to the test project via InternalsVisibleTo so PRs 67-69 can stack read/write/discovery/subscribe on the same serialization. Scaffold tests (OpcUaClientDriverScaffoldTests, 5 facts): Default_options_target_standard_opcua_port_and_anonymous_auth (4840 + None mode + Anonymous + AutoAccept=false production default), Default_timeouts_match_driver_specs_section_8 (120s/5s/5s), Driver_reports_type_and_id_before_connect (DriverType=OpcUaClient, DriverInstanceId round-trip, pre-init Unknown health), Initialize_against_unreachable_endpoint_transitions_to_Faulted_and_throws, Reinitialize_against_unreachable_endpoint_re_throws. Uses opc.tcp://127.0.0.1:1 as the 'guaranteed-unreachable' target -- RFC 5737 reserved IPs get black-holed and time out only after the SDK's internal retry/backoff fully elapses (~60s), while port 1 on loopback refuses immediately with TCP RST which keeps the test suite snappy (5 tests / 8s). 5/5 pass. dotnet build clean. Scope boundary: ITagDiscovery / IReadable / IWritable / ISubscribable / IHostConnectivityProbe deliberately NOT in this PR -- they need browse + namespace remapping + reference-counted MonitoredItem forwarding + keep-alive probing and land in PRs 67-69.
2026-04-19 01:07:57 -04:00