Files
lmxopcua/tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests/LocalDb
Joseph Doherty 47f0b98c6e
v2-ci / unit-tests (push) Has been cancelled
chore(deps): pin ZB.MOM.WW.LocalDb 0.3.8 (scadaproj#57)
LocalDb 0.3.8 ends open sync streams on ApplicationStopping and refuses
new ones Unavailable while stopping (lmxopcua#906, library side). The
host-side ShutdownStreamCancellationInterceptor stays: it also covers
the mesh telemetry/command streams.

GracefulStopWithOpenSyncStreamTests' positive control started passing
the stop in ~950 ms under 0.3.8, because the library alone now ends
the stream. The control registers LocalDbSyncService without the host
lifetime (the 0.3.7 behaviour), so it still reproduces the 8 s drain.

Release build 0 warnings. Host.Tests 288/288, Host.IntegrationTests
350 passed / 2 skipped, Runtime.Tests 1063 passed / 3 skipped,
Core.AlarmHistorian.Tests 53/53.

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 06:55:27 -05:00
..