Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusEdgeCaseValidationTests.cs
T

86 lines
4.4 KiB
C#

using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
/// <summary>
/// Regression coverage for Driver.Modbus-009: two configuration edge cases that previously
/// silently produced wrong wire behaviour.
/// (1) <c>StringLength = 0</c> for a <c>String</c>-typed tag — used to flow into an FC03
/// with quantity 0, a spec-illegal request the PLC rejects with exception 03. In v3 the guard
/// moved to the pure mapper (<see cref="ModbusTagDefinitionFactory.FromTagConfig"/>): a String
/// tag with <c>stringLength &lt; 1</c> fails to map (⇒ the driver skips it / surfaces
/// <c>BadNodeIdUnknown</c>) instead of the factory throwing at bind time.
/// (2) Sub-second <see cref="TimeSpan"/> values on <c>ModbusKeepAliveOptions.Time</c> /
/// <c>Interval</c> — the int-cast in <c>EnableKeepAlive</c> truncated <c>500&#160;ms</c> to
/// <c>0</c>, which most OSes interpret as "use the default", silently defeating the
/// configured timing. <c>ModbusSocketLifecycle.ClampToWholeSeconds</c> rounds up to a minimum
/// of 1&#160;second.
/// </summary>
[Trait("Category", "Unit")]
public sealed class ModbusEdgeCaseValidationTests
{
private const string RawPath = "cell/modbus/dev1/Greeting";
/// <summary>Verifies that a String tag with an explicit zero length fails to map.</summary>
[Fact]
public void Mapper_rejects_String_tag_with_StringLength_zero_explicit()
{
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String","stringLength":0}""";
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeFalse();
}
/// <summary>Verifies that a String tag with an omitted length (defaults to zero) fails to map.</summary>
[Fact]
public void Mapper_rejects_String_tag_with_StringLength_zero_missing_field()
{
// No stringLength → defaults to 0. Same misconfiguration via a different blob shape.
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String"}""";
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeFalse();
}
/// <summary>Verifies that a String tag with length one maps successfully.</summary>
[Fact]
public void Mapper_accepts_String_tag_with_StringLength_one()
{
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"String","stringLength":1}""";
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out var def).ShouldBeTrue();
def.StringLength.ShouldBe((ushort)1);
}
/// <summary>Verifies that non-String tags are unaffected by a zero string length.</summary>
[Fact]
public void Mapper_accepts_non_String_tag_with_StringLength_zero()
{
// The guard only kicks in for String tags — Int16 tags with StringLength=0 are normal.
const string json = """{"region":"HoldingRegisters","address":100,"dataType":"Int16"}""";
ModbusTagDefinitionFactory.FromTagConfig(json, RawPath, out _).ShouldBeTrue();
}
/// <summary>Verifies that sub-second time spans are rounded up to at least one second.</summary>
/// <param name="ms">The input duration in milliseconds.</param>
/// <param name="expected">The expected clamped value in whole seconds.</param>
[Theory]
[InlineData(0, 1)] // zero clamps up to 1
[InlineData(500, 1)] // 500 ms rounds up to 1
[InlineData(999, 1)] // just under 1s rounds up to 1
[InlineData(1_000, 1)] // exactly 1s passes through
[InlineData(1_500, 2)] // 1.5s rounds up to 2
[InlineData(30_000, 30)] // historical PR 53 default — unchanged
[InlineData(60_000, 60)]
public void ClampToWholeSeconds_rounds_up_to_at_least_one_second(int ms, int expected)
{
ModbusSocketLifecycle.ClampToWholeSeconds(TimeSpan.FromMilliseconds(ms)).ShouldBe(expected);
}
/// <summary>Verifies that negative time spans are treated as one second.</summary>
[Fact]
public void ClampToWholeSeconds_treats_negative_TimeSpan_as_one_second()
{
// Defensive — operators occasionally configure a negative TimeSpan thinking it disables
// the feature. The OS would reject the negative int — clamping to 1 keeps the socket
// valid until the operator fixes the config.
ModbusSocketLifecycle.ClampToWholeSeconds(TimeSpan.FromSeconds(-5)).ShouldBe(1);
}
}