Joseph Doherty 6d290adb37 Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)
Replicated the Modbus #218 bring-up against the AB CIP + S7 seeds to
confirm the factories + seeds shipped in #217 actually work end-to-end.
Both pass 5/5 e2e stages with `OpcUaServer:AnonymousRoles=[WriteOperate]`
(the #221 knob).

## AB CIP (against ab_server controllogix fixture, port 44818)

```
=== AB CIP e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge           (driver → server → client)
[PASS] OPC UA write bridge     (client → server → driver)
[PASS] Subscribe sees change
```

Server log: `DriverInstance abcip-smoke-drv (AbCip) registered +
initialized` ✓.

## S7 (against python-snap7 s7_1500 fixture, port 1102)

```
=== S7 e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge
[PASS] OPC UA write bridge
[PASS] Subscribe sees change
```

Server log: `DriverInstance s7-smoke-drv (S7) registered + initialized` ✓.

## Seed fixes so bring-up is idempotent

Live-boot exposed two seed-level papercuts when applying multiple
smoke seeds in sequence:

1. **SA credential collision.** `UX_ClusterNodeCredential_Value` is a
   unique index on `(Kind, Value) WHERE Enabled=1`, so `sa` can only
   bind to one node at a time. Each seed's DELETE block only dropped
   the credential tied to ITS node — seeding AbCip after Modbus blew
   up with `Cannot insert duplicate key` on the sa binding. Added a
   global `DELETE FROM dbo.ClusterNodeCredential WHERE Kind='SqlLogin'
   AND Value='sa'` before the per-cluster INSERTs. Production deployments
   using non-SA logins aren't affected.

2. **DashboardPort 5000 → 15050.** `HealthEndpointsHost` uses
   `HttpListener`, which rejects port 5000 on Windows without a
   `netsh http add urlacl` grant or admin rights. 15050 is unreserved
   + loopback-safe per the HealthEndpointsHost remarks. Applied to all
   four smoke seeds (Modbus was patched at runtime in #218; now baked
   into the seed).

## AB Legacy status

Not live-boot verified — ab_server PCCC dispatcher is upstream-broken
(#222). The factory + seed ship ready for hardware; the seed's DELETE
+ DashboardPort fixes land in this PR so when real SLC/MicroLogix/PLC-5
arrives the sql just applies.

## Closes #220

Umbrella #209 was already closed; #220 was the final child.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:02:40 -04:00
..
Phase 2 Stream D progress — non-destructive deliverables: appsettings → DriverConfig migration script, two-service Windows installer scripts, process-spawn cross-FX parity test, Stream D removal procedure doc with both Option A (rewrite 494 v1 tests) and Option B (archive + new v2 E2E suite) spelled out step-by-step. Cannot one-shot the actual legacy-Host deletion in any unattended session — explained in the procedure doc; the parity-defect debug cycle is intrinsically interactive (each iteration requires inspecting a v1↔v2 diff and deciding if it's a legitimate v2 improvement or a regression, then either widening the assertion or fixing the v2 code), and git rm -r src/ZB.MOM.WW.OtOpcUa.Host is destructive enough to need explicit operator authorization on a real PR review. scripts/migration/Migrate-AppSettings-To-DriverConfig.ps1 takes a v1 appsettings.json and emits the v2 DriverInstance.DriverConfig JSON blob (MxAccess/Database/Historian sections) ready to upsert into the central Configuration DB; null-leaf stripping; -DryRun mode; smoke-tested against the dev appsettings.json and produces the expected three-section ordered-dictionary output. scripts/install/Install-Services.ps1 registers the two v2 services with sc.exe — OtOpcUaGalaxyHost first (net48 x86 EXE with OTOPCUA_GALAXY_PIPE/OTOPCUA_ALLOWED_SID/OTOPCUA_GALAXY_SECRET/OTOPCUA_GALAXY_BACKEND/OTOPCUA_GALAXY_ZB_CONN/OTOPCUA_GALAXY_CLIENT_NAME env vars set via HKLM:\SYSTEM\CurrentControlSet\Services\OtOpcUaGalaxyHost\Environment registry), then OtOpcUa with depend=OtOpcUaGalaxyHost; resolves down-level account names to SID for the IPC ACL; generates a fresh 32-byte base64 shared secret per install if not supplied (kept out of registry — operators record offline for service rebinding scenarios); echoes start commands. scripts/install/Uninstall-Services.ps1 stops + removes both services. tests/ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Proxy.Tests/HostSubprocessParityTests.cs is the production-shape parity test — Proxy (.NET 10) spawns the actual OtOpcUa.Driver.Galaxy.Host.exe (net48 x86) as a subprocess via Process.Start with backend=db env vars, connects via real named pipe, calls Discover, asserts at least one Galaxy gobject comes back. Skipped when running as Administrator (PipeAcl denies admins, same guard as other IPC integration tests), when the Host EXE hasn't been built, or when the ZB SQL endpoint is unreachable. This is the cross-FX integration that the parity suite genuinely needs — the previous IPC tests all ran in-process; this one validates the production deployment topology where Proxy and Host are separate processes communicating only over the named pipe. docs/v2/implementation/stream-d-removal-procedure.md is the next-session playbook: Option A (rewrite 494 v1 tests via a ProxyMxAccessClientAdapter that implements v1's IMxAccessClient by forwarding to GalaxyProxyDriver — Vtq↔DataValueSnapshot, Quality↔StatusCode, OnTagValueChanged↔OnDataChange mapping; 3-5 days, full coverage), Option B (rename OtOpcUa.Tests → OtOpcUa.Tests.v1Archive with [Trait("Category", "v1Archive")] for opt-in CI runs; new OtOpcUa.Driver.Galaxy.E2E test project with 10-20 representative tests via the HostSubprocessParityTests pattern; 1-2 days, accreted coverage); deletion checklist with eight pre-conditions, ten ordered steps, and a rollback path (git revert restores the legacy Host alongside the v2 stack — both topologies remain installable until the downstream consumer cutover). Full solution 964 pass / 1 pre-existing Phase 0 baseline; the 494 v1 IntegrationTests + 6 v1 IntegrationTests-net48 still pass because legacy OtOpcUa.Host stays untouched until an interactive session executes the procedure doc.