fd64fed217
I1: Task.WhenAll waits for the slowest device, so concurrency alone still let a device that accepts TCP and then stalls cost (its tag count x call timeout) per batch. After the first timeout, transport failure or comms-class status on a device, its remaining tags in the batch now fail BadCommunicationError immediately, the same as the coalescer's FailMembers, which now also stops after a failed range. FIXED: tags are still served from the cache. A malformed address is BadNodeIdUnknown and does not count as a link failure. Test: a 10-tag stalled device beside a healthy one completes in under 3 call timeouts with the healthy value Good. The P9 test now also asserts per-client read counts and that two reads overlapped across devices. Minors: - 1: a superseded init releases its table only if it was never published (flag). - 2: a fixed-tree refusal credits LastSuccessfulRead; a value-path refusal after a comms fault restores Healthy. - 5: alarm/fixed/refusal health is reset inside the publish lock, after the generation check. - 6: FocasFixedTreeHealthTests wait on served-failure/refusal counters, not wall-clock. - 8: data-path health writes (reads, coalescer, writes, poll errors, refusals) carry the generation they started under and are dropped once a lifecycle call has moved on. Each write is a check-and-set under the lifecycle lock. Also adds a unit case where 20 vendor records with type 0 and empty messages stay vendor. Refs #740 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
161 lines
7.5 KiB
C#
161 lines
7.5 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Wire;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Tests;
|
|
|
|
/// <summary>
|
|
/// #740 / R07:H15 — the fixed-tree loop swallowed every failure at Debug and never touched driver health, so a
|
|
/// driver serving only <c>FIXED:</c> tags (Identity / Axes / Program / Status — the typical FOCAS shape) read
|
|
/// Healthy on <c>/hosts</c> with every node Bad, and the #527 comms-loss watchdog could never fire. The loop
|
|
/// now credits each answered axis pass (Healthy + LastSuccessfulRead) and, once a device has been silent past
|
|
/// the fixed-tree staleness budget, degrades the driver with LastSuccessfulRead frozen.
|
|
/// </summary>
|
|
[Trait("Category", "Unit")]
|
|
public sealed class FocasFixedTreeHealthTests
|
|
{
|
|
private const string Host = "focas://10.0.0.5:8193";
|
|
private static readonly TimeSpan Stale = TimeSpan.FromMilliseconds(300);
|
|
|
|
/// <summary>A CNC that can be switched off (transport failure) or made to refuse the dynamic read.</summary>
|
|
private sealed class CncSwitch
|
|
{
|
|
public volatile bool Down;
|
|
public volatile bool Refuse;
|
|
/// <summary>Transport failures served so far — what the tests wait on instead of wall-clock delays.</summary>
|
|
public int Failures;
|
|
/// <summary>Refusals served so far.</summary>
|
|
public int Refusals;
|
|
}
|
|
|
|
private sealed class SwitchableCnc(CncSwitch sw) : FakeFocasClient
|
|
{
|
|
private bool Down => sw.Down;
|
|
private bool Refuse => sw.Refuse;
|
|
|
|
public override Task<FocasSysInfo> GetSysInfoAsync(CancellationToken ct)
|
|
{
|
|
if (!Down) return base.GetSysInfoAsync(ct);
|
|
Interlocked.Increment(ref sw.Failures);
|
|
throw new IOException("socket closed");
|
|
}
|
|
|
|
public override Task<FocasDynamicSnapshot> ReadDynamicAsync(int axisIndex, CancellationToken ct)
|
|
{
|
|
if (Down)
|
|
{
|
|
Interlocked.Increment(ref sw.Failures);
|
|
throw new IOException("socket closed");
|
|
}
|
|
if (Refuse)
|
|
{
|
|
Interlocked.Increment(ref sw.Refusals);
|
|
throw new FocasWireException("cnc_rddynamic2 refused", rc: 6);
|
|
}
|
|
return base.ReadDynamicAsync(axisIndex, ct);
|
|
}
|
|
}
|
|
|
|
private static FocasDriver FixedOnlyDriver(CncSwitch sw) => new(new FocasDriverOptions
|
|
{
|
|
Devices = [new FocasDeviceOptions(Host)],
|
|
RawTags = [FocasRawTags.Entry(new FocasTagDefinition("raw/X", Host, "FIXED:Axes/X/AbsolutePosition", FocasDataType.Float64))],
|
|
Probe = new FocasProbeOptions { Enabled = false },
|
|
FixedTree = new FocasFixedTreeOptions
|
|
{
|
|
PollInterval = TimeSpan.FromMilliseconds(20),
|
|
ProgramPollInterval = TimeSpan.Zero,
|
|
TimerPollInterval = TimeSpan.Zero,
|
|
},
|
|
}, "focas-fixed-health", new FakeFocasClientFactory { Customise = () => new SwitchableCnc(sw) })
|
|
{
|
|
FixedTreeStaleBudgetOverride = Stale,
|
|
};
|
|
|
|
/// <summary>
|
|
/// Positive control first, then the outage: an answering CNC keeps the driver Healthy with a moving
|
|
/// LastSuccessfulRead; a CNC that stops answering degrades it once the budget passes, with
|
|
/// LastSuccessfulRead frozen (the watchdog's conjunction); and its return restores Healthy.
|
|
/// </summary>
|
|
[Fact]
|
|
public async Task Fixed_only_driver_degrades_when_its_cnc_disappears_and_recovers_when_it_returns()
|
|
{
|
|
var sw = new CncSwitch();
|
|
await using var drv = FixedOnlyDriver(sw);
|
|
await drv.InitializeAsync("{}", CancellationToken.None);
|
|
await WaitUntil(() => drv.GetDeviceState(Host)?.LastFixedPollUtc is not null);
|
|
|
|
var first = drv.GetHealth().LastSuccessfulRead!.Value;
|
|
// An answered axis pass is a successful read: wait for it to move rather than sleeping.
|
|
await WaitUntil(() => drv.GetHealth().LastSuccessfulRead > first);
|
|
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
|
|
|
sw.Down = true;
|
|
var lastAnswer = drv.GetDeviceState(Host)!.LastFixedPollUtc!.Value;
|
|
// Two failed ticks have demonstrably happened (positive evidence for the absence check below) …
|
|
await WaitUntil(() => Volatile.Read(ref sw.Failures) >= 2);
|
|
// … and, if they landed inside the budget, the driver is still Healthy.
|
|
if (DateTime.UtcNow - lastAnswer < Stale)
|
|
drv.GetHealth().State.ShouldBe(DriverState.Healthy, "a blip inside the staleness budget does not degrade");
|
|
await WaitUntil(() => drv.GetHealth().State == DriverState.Degraded);
|
|
var frozen = drv.GetHealth().LastSuccessfulRead;
|
|
var failuresAtDegrade = Volatile.Read(ref sw.Failures);
|
|
await WaitUntil(() => Volatile.Read(ref sw.Failures) >= failuresAtDegrade + 5);
|
|
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
|
drv.GetHealth().LastSuccessfulRead.ShouldBe(frozen, "LastSuccessfulRead must stay frozen while the CNC is silent");
|
|
|
|
sw.Down = false;
|
|
await WaitUntil(() => drv.GetHealth().State == DriverState.Healthy);
|
|
drv.GetHealth().LastSuccessfulRead!.Value.ShouldBeGreaterThan(frozen!.Value);
|
|
}
|
|
|
|
/// <summary>A CNC that is down from the start (bootstrap never succeeds) degrades once the budget passes.</summary>
|
|
[Fact]
|
|
public async Task Bootstrap_that_never_succeeds_degrades_the_driver()
|
|
{
|
|
var sw = new CncSwitch { Down = true };
|
|
await using var drv = FixedOnlyDriver(sw);
|
|
await drv.InitializeAsync("{}", CancellationToken.None);
|
|
// The bootstrap retries every 2 s, so the first failure is what has to trip it.
|
|
await WaitUntil(() => drv.GetHealth().State == DriverState.Degraded, TimeSpan.FromSeconds(6));
|
|
sw.Down = false;
|
|
}
|
|
|
|
/// <summary>
|
|
/// A CNC that ANSWERS with a refusal is not a comms loss: the transport is fine, so the driver is not
|
|
/// degraded (else the watchdog would reconnect-loop a production control).
|
|
/// </summary>
|
|
[Fact]
|
|
public async Task Cnc_refusal_of_the_dynamic_read_does_not_degrade()
|
|
{
|
|
var sw = new CncSwitch();
|
|
await using var drv = FixedOnlyDriver(sw);
|
|
await drv.InitializeAsync("{}", CancellationToken.None);
|
|
await WaitUntil(() => drv.GetDeviceState(Host)?.LastFixedPollUtc is not null);
|
|
|
|
sw.Refuse = true;
|
|
var started = DateTime.UtcNow;
|
|
await WaitUntil(() => Volatile.Read(ref sw.Refusals) >= 1);
|
|
var atFirstRefusal = drv.GetHealth().LastSuccessfulRead!.Value;
|
|
// Refused ticks really happened, for longer than the staleness budget …
|
|
await WaitUntil(() => Volatile.Read(ref sw.Refusals) >= 5 && DateTime.UtcNow - started > Stale * 2);
|
|
// … and the driver stayed Healthy, with each refusal crediting the answer (review minor 2).
|
|
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
|
drv.GetHealth().LastSuccessfulRead!.Value.ShouldBeGreaterThan(atFirstRefusal,
|
|
"a refusal is an answer from the CNC — LastSuccessfulRead advances");
|
|
sw.Refuse = false;
|
|
}
|
|
|
|
private static async Task WaitUntil(Func<bool> condition, TimeSpan? timeout = null)
|
|
{
|
|
var deadline = DateTime.UtcNow + (timeout ?? TimeSpan.FromSeconds(5));
|
|
while (!condition())
|
|
{
|
|
if (DateTime.UtcNow > deadline) throw new TimeoutException("condition not reached");
|
|
await Task.Delay(10);
|
|
}
|
|
}
|
|
}
|