Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
51 lines
2.3 KiB
C#
51 lines
2.3 KiB
C#
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Core.ScriptedAlarms;
|
|
|
|
/// <summary>
|
|
/// Operator-authored scripted-alarm configuration. Phase 7 Stream E (config DB schema)
|
|
/// materializes these from the <c>ScriptedAlarm</c> + <c>Script</c> tables on publish.
|
|
/// </summary>
|
|
/// <param name="AlarmId">
|
|
/// Stable identity for the alarm — used as the OPC UA ConditionId + the key in the
|
|
/// state store. Should be globally unique within the cluster; convention is
|
|
/// <c>{EquipmentPath}::{AlarmName}</c>.
|
|
/// </param>
|
|
/// <param name="EquipmentPath">
|
|
/// UNS path of the Equipment node the alarm hangs under. Alarm browse lives here;
|
|
/// ACL binding inherits this equipment's scope per Phase 6.2.
|
|
/// </param>
|
|
/// <param name="AlarmName">Human-readable alarm name — used in the browse tree + Admin UI.</param>
|
|
/// <param name="Kind">Concrete OPC UA Part 9 subtype the alarm materializes as.</param>
|
|
/// <param name="Severity">Static severity; not currently computed by the predicate.</param>
|
|
/// <param name="MessageTemplate">
|
|
/// Message text with <c>{TagPath}</c> tokens resolved at event-emission time.
|
|
/// Unresolvable tokens emit <c>{?}</c> + a structured
|
|
/// error so operators can spot stale references.
|
|
/// </param>
|
|
/// <param name="PredicateScriptSource">
|
|
/// Roslyn C# script returning <c>bool</c>. <c>true</c> = alarm condition currently holds (active);
|
|
/// <c>false</c> = condition has cleared. Same sandbox rules as virtual tags.
|
|
/// </param>
|
|
/// <param name="HistorizeToAveva">
|
|
/// When true, every transition emission of this alarm flows to the Historian alarm
|
|
/// sink (Stream D). Defaults to true — plant alarm history is usually the
|
|
/// operator's primary diagnostic. Galaxy-native alarms default false since Galaxy
|
|
/// historises them directly.
|
|
/// </param>
|
|
/// <param name="Retain">
|
|
/// Part 9 retain flag — when true, the condition node remains visible after the
|
|
/// predicate clears as long as it has un-acknowledged or un-confirmed transitions.
|
|
/// Default true.
|
|
/// </param>
|
|
public sealed record ScriptedAlarmDefinition(
|
|
string AlarmId,
|
|
string EquipmentPath,
|
|
string AlarmName,
|
|
AlarmKind Kind,
|
|
AlarmSeverity Severity,
|
|
string MessageTemplate,
|
|
string PredicateScriptSource,
|
|
bool HistorizeToAveva = true,
|
|
bool Retain = true);
|