Files
lmxopcua/tests
Joseph Doherty 447086892e AB CIP PR 5 — ITagDiscovery (pre-declared emission + controller-enumeration scaffolding). DiscoverAsync streams tags to IAddressSpaceBuilder with the same shape the Modbus driver uses, keyed by device host address so one driver instance exposing N PLCs produces N device folders under a shared "AbCip" root. Pre-declared tags from AbCipDriverOptions.Tags emit first, filtered through AbCipSystemTagFilter so __DEFVAL_* / __DEFAULT_* / Routine: / Task: / Local:N:X / Map: / Axis: / Cam: / MotionGroup: infrastructure names never reach the address space. Writable tags map to SecurityClassification.Operate, non-writable to ViewOnly. Controller enumeration (walking the Logix Symbol Object via @tags) is wired up through a new IAbCipTagEnumerator + IAbCipTagEnumeratorFactory abstraction — default EmptyAbCipTagEnumeratorFactory returns an empty sequence so the driver stays production-safe without a real decoder. Tests inject FakeEnumeratorFactory to exercise the discovered-tag path: discovered tags land under a Discovered/ sub-folder, program-scope produces Program:P.Name full references, the IsSystemTag hint + the AbCipSystemTagFilter both act as gates, ReadOnly surfaces SecurityClassification.ViewOnly. The real @tags walker is a follow-up because libplctag 1.5.2 (latest stable on NuGet) does not expose TagInfoPlcMapper / UdtInfoMapper — the DataTypes namespace only ships IPlcMapper<T>, so enumerating the Symbol Object requires either implementing a custom IPlcMapper for the CIP byte layout or raw-buffer decoding via plc_tag_get_raw — both non-trivial enough to warrant their own PR. Code comment on EmptyAbCipTagEnumerator documents the gap + points to the follow-up. AbCipTemplateCache placeholder ships with a ConcurrentDictionary<(device, templateInstanceId), AbCipUdtShape> + Put / TryGet / Clear / Count — the Template Object reader (CIP class 0x6C) populates it in PR 6 and FlushOptionalCachesAsync now clears it. AbCipUdtShape + AbCipUdtMember records describe UDT layout — type name + total size + ordered members with offset / type / array length. AbCipDriver ctor gains optional enumeratorFactory parameter matching the tagFactory pattern from PR 3. TemplateCache exposed internally for PR 6's reader to write into. 25 new unit tests in AbCipDriverDiscoveryTests covering — pre-declared emission under device folder, DeviceName fallback to host address, system-tag filter rejecting pre-declared infrastructure names, cross-device tag filtering (tags for a device this driver does not own are ignored), controller enumeration adds tags under Discovered/, system-tag hint + filter both enforced, ReadOnly → ViewOnly, AbCipTagCreateParams composition (gateway / port / CIP path / libplctag attribute / tag name "@tags" / timeout), default enumerator factory used when not injected, 13 Theory cases covering every AbCipSystemTagFilter pattern, template cache roundtrip + clear, FlushOptionalCachesAsync clears the cache. Total AbCip unit tests now 123/123 passing (+25 from PR 4's 98). Modbus + other existing tests untouched; full solution builds 0 errors. Unblocks PR 6 (UDT structured read/write) + PR 7 (subscriptions consuming PollGroupEngine from PR 1).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 17:05:02 -04:00
..
AB CIP PR 1 — extract shared PollGroupEngine into Core.Abstractions so the AB CIP driver (and any other poll-based driver — S7, FOCAS, AB Legacy) can reuse the subscription loop instead of reimplementing it. Behaviour-preserving refactor of ModbusDriver: SubscriptionState + PollLoopAsync + PollOnceAsync + ModbusSubscriptionHandle lifted verbatim into a new PollGroupEngine class, ModbusDriver's ISubscribable surface now delegates Subscribe/Unsubscribe into the engine and ShutdownAsync calls engine DisposeAsync. Interval floor (100 ms default) becomes a PollGroupEngine constructor knob so per-driver tuning is possible without re-shipping the loop. Initial-data push semantics preserved via forceRaise=true on the first poll. Exception-tolerant loop preserved — reader throws are swallowed, loop continues, driver's health surface remains the single reporting path. Placement in Core.Abstractions (not Core) because driver projects only reference Core.Abstractions by convention (matches OpcUaClient / Modbus / S7 csproj shape); putting the engine in Core would drag EF Core + Serilog + Polly into every driver. Module has no new dependencies beyond System.Collections.Concurrent + System.Threading, so Core.Abstractions stays lightweight. Modbus ctor converted from primary to explicit so the engine field can capture this for the reader + on-change bridge. All 177 ModbusDriver.Tests pass unmodified (Modbus subscription suite, probe suite, cap suite, exception mapper, reconnect, TCP). 10 new direct engine tests in Core.Abstractions.Tests covering: initial force-raise, unchanged-value single-raise, change-between-polls, unsubscribe halts loop, interval-floor clamp, independent subscriptions, reader-exception tolerance, unknown-handle returns false, ActiveSubscriptionCount lifecycle, DisposeAsync cancels all. No changes to driver-specs.md nor to the server Hosting layer — engine is a pure internal building block at this stage. Unblocks AB CIP PR 7 (ISubscribable consumes the engine); also sets up S7 + FOCAS to drop their own poll loops when they re-base.
2026-04-19 15:34:44 -04:00
AB CIP PR 3 — IReadable implementation against libplctag. Introduces IAbCipTagRuntime + IAbCipTagFactory abstraction matching the Modbus transport-factory pattern (ctor optional arg, default production impl injected) so the driver's read/status-mapping logic is unit-testable without a live PLC or the native libplctag binary. LibplctagTagRuntime is the default wire-backed implementation — wraps libplctag.Tag + translates our AbCipDataType enum into GetInt8/GetUInt8/GetInt16/GetUInt16/GetInt32/GetUInt32/GetInt64/GetUInt64/GetFloat32/GetFloat64/GetString/GetBit calls covering Bool (standalone + BOOL-in-DINT via .N bit selector), SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real, LReal, String, Dt (epoch DINT), with Structure deferred to PR 6. MapPlcType bridges our libplctag attribute strings (controllogix, compactlogix, micro800) to libplctag.PlcType enum; CompactLogix rolls under ControlLogix per libplctag's family grouping which matches the wire protocol reality. AbCipDriver now implements IReadable — ReadAsync iterates fullReferences preserving order, looks up each tag definition + its device, lazily materialises the tag runtime via EnsureTagRuntimeAsync on first touch (cached thereafter for the lifetime of the device), catches OperationCanceledException to honor cancellation, maps libplctag non-zero status via AbCipStatusMapper.MapLibplctagStatus, catches any other exception as BadCommunicationError. Health surface moves to Healthy on success + Degraded with the last error message on failure. Initialize-failure path disposes the half-created runtime before rethrowing so no native handles leak. DeviceState gains a Runtimes dict alongside the existing TagHandles collection; DisposeHandles walks both so ShutdownAsync + ReinitializeAsync cleanly destroy every native tag. 12 new unit tests in AbCipDriverReadTests using FakeAbCipTag / FakeAbCipTagFactory (test fake under tests/...AbCip.Tests/FakeAbCipTag.cs) covering unknown reference → BadNodeIdUnknown, unknown device → BadNodeIdUnknown, successful DInt read with correct Good status + captured value, lazy-init on first read with reuse across subsequent reads, non-zero libplctag status mapping via AbCipStatusMapper, exception during read surfacing as BadCommunicationError with health Degraded, batched reads preserving order + per-tag status, health Healthy after success, TagCreateParams composition from device + profile (gateway / port / CIP path / libplctag attribute / tag name wiring), cancellation propagation via OperationCanceledException, ShutdownAsync disposing every runtime, Initialize-failure disposing the aborted runtime. Total AbCip unit tests now 88/88 passing. Integration test project scaffolding — tests/ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests with AbServerFixture (IAsyncLifetime that starts ab_server when the binary is on PATH, otherwise marks IsAvailable=false), AbServerFact attribute (Fact-equivalent that skips when ab_server is missing), one smoke test exercising DInt read end-to-end. Project runs cleanly — the single smoke test skips on boxes without ab_server (0 failed, 0 passed, 1 skipped) + runs on boxes with it. Follow-up work captured in comments — ab_server CI fixture (download prebuilt Windows x64 binary as GitHub release asset) + per-family JSON profiles + hand-rolled CIP stub for UDT fidelity ship in the PR 6/9-12 window. Solution file updated. Full solution builds 0 errors across all 28 projects. Modbus + other existing tests untouched.
2026-04-19 16:38:54 -04:00
AB CIP PR 5 — ITagDiscovery (pre-declared emission + controller-enumeration scaffolding). DiscoverAsync streams tags to IAddressSpaceBuilder with the same shape the Modbus driver uses, keyed by device host address so one driver instance exposing N PLCs produces N device folders under a shared "AbCip" root. Pre-declared tags from AbCipDriverOptions.Tags emit first, filtered through AbCipSystemTagFilter so __DEFVAL_* / __DEFAULT_* / Routine: / Task: / Local:N:X / Map: / Axis: / Cam: / MotionGroup: infrastructure names never reach the address space. Writable tags map to SecurityClassification.Operate, non-writable to ViewOnly. Controller enumeration (walking the Logix Symbol Object via @tags) is wired up through a new IAbCipTagEnumerator + IAbCipTagEnumeratorFactory abstraction — default EmptyAbCipTagEnumeratorFactory returns an empty sequence so the driver stays production-safe without a real decoder. Tests inject FakeEnumeratorFactory to exercise the discovered-tag path: discovered tags land under a Discovered/ sub-folder, program-scope produces Program:P.Name full references, the IsSystemTag hint + the AbCipSystemTagFilter both act as gates, ReadOnly surfaces SecurityClassification.ViewOnly. The real @tags walker is a follow-up because libplctag 1.5.2 (latest stable on NuGet) does not expose TagInfoPlcMapper / UdtInfoMapper — the DataTypes namespace only ships IPlcMapper<T>, so enumerating the Symbol Object requires either implementing a custom IPlcMapper for the CIP byte layout or raw-buffer decoding via plc_tag_get_raw — both non-trivial enough to warrant their own PR. Code comment on EmptyAbCipTagEnumerator documents the gap + points to the follow-up. AbCipTemplateCache placeholder ships with a ConcurrentDictionary<(device, templateInstanceId), AbCipUdtShape> + Put / TryGet / Clear / Count — the Template Object reader (CIP class 0x6C) populates it in PR 6 and FlushOptionalCachesAsync now clears it. AbCipUdtShape + AbCipUdtMember records describe UDT layout — type name + total size + ordered members with offset / type / array length. AbCipDriver ctor gains optional enumeratorFactory parameter matching the tagFactory pattern from PR 3. TemplateCache exposed internally for PR 6's reader to write into. 25 new unit tests in AbCipDriverDiscoveryTests covering — pre-declared emission under device folder, DeviceName fallback to host address, system-tag filter rejecting pre-declared infrastructure names, cross-device tag filtering (tags for a device this driver does not own are ignored), controller enumeration adds tags under Discovered/, system-tag hint + filter both enforced, ReadOnly → ViewOnly, AbCipTagCreateParams composition (gateway / port / CIP path / libplctag attribute / tag name "@tags" / timeout), default enumerator factory used when not injected, 13 Theory cases covering every AbCipSystemTagFilter pattern, template cache roundtrip + clear, FlushOptionalCachesAsync clears the cache. Total AbCip unit tests now 123/123 passing (+25 from PR 4's 98). Modbus + other existing tests untouched; full solution builds 0 errors. Unblocks PR 6 (UDT structured read/write) + PR 7 (subscriptions consuming PollGroupEngine from PR 1).
2026-04-19 17:05:02 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
2026-04-18 23:07:00 -04:00
Phase 3 PR 76 -- OPC UA Client IHistoryProvider (HistoryRead passthrough). Driver now implements IHistoryProvider (Raw + Processed + AtTime); ReadEventsAsync deliberately inherits the interface default that throws NotSupportedException. ExecuteHistoryReadAsync is the shared wire path: parses the fullReference to NodeId, builds a HistoryReadValueIdCollection with one entry, calls Session.HistoryReadAsync(RequestHeader, ExtensionObject<details>, TimestampsToReturn.Both, releaseContinuationPoints:false, nodesToRead, ct), unwraps r.HistoryData ExtensionObject into the samples list, passes ContinuationPoint through. Each DataValue's upstream StatusCode + SourceTimestamp + ServerTimestamp preserved verbatim per driver-specs.md \u00A78 cascading-quality rule -- this matters especially for historical data where an interpolated / uncertain-quality sample must surface its true severity downstream, not a sanitized Good. SourceTimestamp=DateTime.MinValue guards map to null so downstream clients see 'source unknown' rather than an epoch-zero misread. ReadRawAsync builds ReadRawModifiedDetails with IsReadModified=false (raw, not modified-history), StartTime/EndTime, NumValuesPerNode=maxValuesPerNode, ReturnBounds=false (clients that want bounds request them via continuation handling). ReadProcessedAsync builds ReadProcessedDetails with ProcessingInterval in ms + AggregateType wrapping a single NodeId from MapAggregateToNodeId. MapAggregateToNodeId switches on HistoryAggregateType {Average, Minimum, Maximum, Total, Count} to the standard Part 13 ObjectIds.AggregateFunction_* NodeId -- future aggregate-type additions fail the switch with ArgumentOutOfRangeException so they can't silently slip through with a null NodeId and an opaque server-side BadAggregateNotSupported. ReadAtTimeAsync builds ReadAtTimeDetails with ReqTimes + UseSimpleBounds=true (returns boundary samples when an exact timestamp has no value -- the OPC UA Part 11 default). Malformed NodeId short-circuits to empty result without touching the wire, matching the ReadAsync / WriteAsync pattern. ReadEventsAsync stays at the interface-default NotSupportedException: the OPC UA call path (HistoryReadAsync with ReadEventDetails + EventFilter) needs an EventFilter SelectClauses spec which the current IHistoryProvider.ReadEventsAsync signature doesn't carry. Adding that would be an IHistoryProvider interface widening; out of scope for PR 76. Callers see BadHistoryOperationUnsupported on the OPC UA client which is the documented fallback. Name disambiguation: Core.Abstractions.HistoryReadResult and Opc.Ua.HistoryReadResult both exist; used fully-qualified Core.Abstractions.HistoryReadResult in return types + factory expressions. Shutdown unchanged -- history reads don't create persistent server-side resources, so no cleanup needed beyond the existing Session.CloseAsync. Unit tests (OpcUaClientHistoryTests, 7 facts): MapAggregateToNodeId theory covers all 5 aggregates; MapAggregateToNodeId_rejects_invalid_enum (defense against future enum addition silently passing through); Read{Raw,Processed,AtTime}Async_without_initialize_throws (RequireSession path); ReadEventsAsync_throws_NotSupportedException (locks in the intentional inheritance of the default). 78/78 OpcUaClient.Tests pass (67 prior + 11 new, -4 on the alarm suite moved into the events count). dotnet build clean. Final OPC UA Client capability surface: IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable + IHostConnectivityProbe + IAlarmSource + IHistoryProvider -- 8 of 8 possible capabilities. Driver is feature-complete per driver-specs.md \u00A78.
2026-04-19 02:13:22 -04:00