Joseph Doherty
db56a95819
Phase 3 PR 68 -- OPC UA Client ITagDiscovery via recursive browse (Full strategy). Adds ITagDiscovery to OpcUaClientDriver. DiscoverAsync opens a single Remote folder on the IAddressSpaceBuilder and recursively browses from the configured root (default: ObjectsFolder i=85; override via OpcUaClientDriverOptions.BrowseRoot for scoped discovery). Browse uses non-obsolete Session.BrowseAsync(RequestHeader, ViewDescription, uint maxReferences, BrowseDescriptionCollection, ct) with HierarchicalReferences forward, subtypes included, NodeClassMask Object+Variable, ResultMask pulling BrowseName + DisplayName + NodeClass + TypeDefinition. Objects become sub-folders via builder.Folder; Variables become builder.Variable entries with FullName set to the NodeId.ToString() serialization so IReadable/IWritable can round-trip without re-resolving. Three safety caps added to OpcUaClientDriverOptions to bound runaway discovery: (1) MaxBrowseDepth default 10 -- deep enough for realistic OPC UA information models, shallow enough that cyclic graphs can't spin the browse forever. (2) MaxDiscoveredNodes default 10_000 -- caps memory on pathological remote servers. Once the cap is hit, recursion short-circuits and the partially-discovered tree is still projected into the local address space (graceful degradation rather than all-or-nothing). (3) BrowseRoot as an opt-in scope restriction string per driver-specs.md \u00A78 -- defaults to ObjectsFolder but operators with 100k-node servers can point it at a single subtree. Visited-set tracks NodeIds already visited to prevent infinite cycles on graphs with non-strict hierarchy (OPC UA models can have back-references). Transient browse failures on a subtree are swallowed -- the sub-branch stops but the rest of discovery continues, matching the Modbus driver's 'transient poll errors don't kill the loop' pattern. The driver's health surface reflects the network-level cascade via the probe loop (PR 69). Deferred to a follow-up PR: DataType resolution via a batch Session.ReadAsync(Attributes.DataType) after the browse so DriverAttributeInfo.DriverDataType is accurate instead of the current conservative DriverDataType.Int32 default; AccessLevel-derived SecurityClass instead of the current ViewOnly default; array-type detection via Attributes.ValueRank + ArrayDimensions. These need an extra wire round-trip per batch of variables + a NodeId -> DriverDataType mapping table; out of scope for PR 68 to keep browse path landable. Unit tests (OpcUaClientDiscoveryTests, 3 facts): DiscoverAsync_without_initialize_throws_InvalidOperationException (pre-init hits RequireSession); DiscoverAsync_rejects_null_builder (ArgumentNullException); Discovery_caps_are_sensible_defaults (asserts 10000 / 10 / null defaults documented above). NullAddressSpaceBuilder stub implements the full IAddressSpaceBuilder shape including IVariableHandle.MarkAsAlarmCondition (throws NotSupportedException since this PR doesn't wire alarms). Live-browse coverage against a real remote server is deferred to the in-process-server-fixture PR. 10/10 OpcUaClient.Tests pass. dotnet build clean.
2026-04-19 01:17:21 -04:00