Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/serve.ps1
Joseph Doherty 10c724b5b6 Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
2026-04-18 22:57:03 -04:00

61 lines
1.7 KiB
PowerShell

<#
.SYNOPSIS
Launches the pymodbus simulator with one of the integration-test profiles
(Standard or DL205). Foreground process — Ctrl+C to stop.
.PARAMETER Profile
Which simulator profile to run: 'standard' or 'dl205'. Both bind TCP 5020 by
default so they can't run simultaneously on the same box.
.PARAMETER HttpPort
Port for pymodbus's optional web UI / REST API. Default 8080. Pass 0 to
disable (passes --no_http).
.EXAMPLE
.\serve.ps1 -Profile standard
Starts the standard server on TCP 5020 with web UI on 8080.
.EXAMPLE
.\serve.ps1 -Profile dl205 -HttpPort 0
Starts the DL205 server on TCP 5020, no web UI.
#>
[CmdletBinding()]
param(
[Parameter(Mandatory)] [ValidateSet('standard', 'dl205', 's7_1500', 'mitsubishi')] [string]$Profile,
[int]$HttpPort = 8080
)
$ErrorActionPreference = 'Stop'
$here = $PSScriptRoot
# Confirm pymodbus.simulator is on PATH — clearer message than the
# 'CommandNotFoundException' dotnet style.
$cmd = Get-Command pymodbus.simulator -ErrorAction SilentlyContinue
if (-not $cmd) {
Write-Error "pymodbus.simulator not found. Install with: pip install 'pymodbus[simulator]==3.13.0'"
exit 1
}
$jsonFile = Join-Path $here "$Profile.json"
if (-not (Test-Path $jsonFile)) {
Write-Error "Profile config not found: $jsonFile"
exit 1
}
$args = @(
'--modbus_server', 'srv',
'--modbus_device', 'dev',
'--json_file', $jsonFile
)
if ($HttpPort -gt 0) {
$args += @('--http_port', $HttpPort)
Write-Host "Web UI will be at http://localhost:$HttpPort"
} else {
$args += '--no_http'
}
Write-Host "Starting pymodbus simulator: profile=$Profile TCP=localhost:5020"
Write-Host "Ctrl+C to stop."
& pymodbus.simulator @args