Task 14 — the P1 milestone gate. Ran the live /run verification on a docker-dev
rig against the real Mosquitto TLS+auth fixture, and recorded the result.
The gate did its job: it found MQTT was unauthorable in production.
RawDriverTypeDialog's driver-type list is a hand-maintained array that nobody
added MQTT to, so the /raw "New driver" picker never offered it — with every
other layer (contracts, driver, browser, factory, host registration, typed tag
editor) complete and 266 green unit tests. Nothing tied that array to
DriverTypeNames and AdminUI has no bUnit, so no offline test could see it.
Fixed, plus RawDriverTypeDialogParityTests: a reflection parity guard that
fails for ANY DriverTypeNames entry missing from the picker. Verified
falsifiable — RED with "…cannot be authored from the /raw New-driver picker,
so they are unreachable in production: Mqtt" before the one-line fix.
A second gap is left OPEN and documented, not fixed (no task ever covered it):
MqttDriverForm / MqttDeviceForm do not exist, and DriverConfigModal/DeviceModal
have no raw-JSON fallback — so an operator can create an MQTT driver but cannot
author its broker endpoint or credentials. P1 is not operator-complete until
those two razor forms land. The gate authored config via SQL to get past it.
Live gate result (isolated 2-node MAIN stack, image built from this branch,
fixture at 10.100.0.35:8883, AllowUntrustedServerCertificate rather than
pinning the CA into the rig):
- typed MQTT tag editor renders and round-trips; Json shows the JSON-path
field, Raw/Scalar hide it; wildcard topic a/+/c blocked at save; data-type
list offers Float64 and no Double; qos/retainSeed absent on "(driver
default)" and qos:2 written as a number; isHistorized/historianTagname
survive a topic-only edit; SparkplugB renders the P2 placeholder and
switching back keeps Plain values; jsonPath is guidance not a gate in all
three shapes ($ seeded only for a brand-new blank tag, blank stays absent,
clearing saves fine)
- deployed, and both editor-written blobs resolved and served changing live
values through OPC UA (22.8 / 1629, StatusCode Good) — no BadNodeIdUnknown
- the bespoke #-observation browser drove a real broker session and rendered
the fixture's actual topic tree (line1/{counter,state,temperature},
noise/chatter, retained/seed); a Modbus device's picker still correctly
reports "Browsing unavailable"
Also found live and documented (not a code change): both nodes of a redundant
pair run the driver, so a FIXED clientId makes them evict each other forever —
the broker logs "already connected, closing old connection" and both nodes
reconnect every ~2s while still reporting Healthy. Unset (the default) is
correct; confirmed 0 reconnects/60s on both nodes after removing it.
Suites: offline 1134 passed / 0 failed (266 Driver.Mqtt + 730 AdminUI incl. the
3 new guards + 138 Core.Abstractions); live 7/7 against the fixture.
Docs: new docs/drivers/Mqtt.md + Mqtt-Test-Fixture.md (the per-driver + fixture
convention every other driver follows), MQTT rows in docs/drivers/README.md,
TestConnectProbes.md, root README.md, and infra/README.md §3.
CLAUDE.md drift corrected while adding the MQTT endpoints:
- the "every fixture carries project: lmxopcua" claim was false — only the
MQTT fixture does; the filter returns one stack, not the fleet
- lmxopcua-fix.ps1 is Windows-VM-only; on macOS drive the host over ssh/rsync
(and the docker-dev rig itself runs locally under OrbStack)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
13 KiB
Drivers
OtOpcUa is a multi-driver OPC UA server. The Core (ZB.MOM.WW.OtOpcUa.Core + Core.Abstractions + Server) owns the OPC UA stack, address space, session/security/subscription machinery, resilience pipeline, and namespace kinds (Equipment + SystemPlatform). Drivers plug in through capability interfaces defined in src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/:
IDriver— lifecycle (InitializeAsync,ReinitializeAsync,ShutdownAsync,GetHealth)IReadable/IWritable— one-shot reads and writesITagDiscovery— address-space enumerationISubscribable— driver-pushed data-change streamsIHostConnectivityProbe— per-host reachability eventsIPerCallHostResolver— multi-host drivers that route each call to a target endpoint at dispatch timeIAlarmSource— driver-emitted OPC UA A&C eventsIHistoryProvider— driver-side raw / processed / at-time / events HistoryRead (see HistoricalDataAccess.md)IRediscoverable— driver-initiated address-space rebuild notificationsIHistorianDataSource— server-side historian read backend registration (the HistorianGateway backend), distinct from the driver-sideIHistoryProviderHistoryRead path
Each driver opts into only the capabilities it supports. Every async capability call at the Server dispatch layer goes through CapabilityInvoker (Core/Resilience/CapabilityInvoker.cs), which wraps it in a Polly pipeline keyed on (DriverInstanceId, HostName, DriverCapability). The OTOPCUA0001 analyzer enforces the wrap at build time. Drivers themselves never depend on Polly; they just implement the capability interface and let the Core wrap it.
Driver type metadata is registered at startup in DriverTypeRegistry (src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeRegistry.cs). The registry records each type's allowed namespace kinds (Equipment / SystemPlatform / Simulated), its JSON Schema for DriverConfig / DeviceConfig / TagConfig columns, and its stability tier per docs/v2/driver-stability.md.
Ground-truth driver list
| Driver | Project path | Tier | Wire / library | Capabilities | Notable quirk |
|---|---|---|---|---|---|
| Galaxy | Driver.Galaxy (+ .Browser, .Contracts) |
A | gRPC to the external mxaccessgw gateway (the gateway owns MXAccess COM + the Galaxy Repository SQL reader) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IRediscoverable, IHostConnectivityProbe | In-process .NET 10 driver — the COM bitness constraint lives in the gateway's x86 net48 worker, not here. PR 7.2 retired the legacy in-process Galaxy.{Shared, Host, Proxy} + named-pipe Windows service. Native MxAccess alarms work end-to-end |
| Modbus TCP | Driver.Modbus |
A | NModbus-derived in-house client | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | Polled subscriptions via the shared PollGroupEngine. DL205 PLCs are covered by AddressFormat=DL205 (octal V/X/Y/C/T/CT translation) — no separate driver |
| Siemens S7 | Driver.S7 |
A | S7netplus | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe | Single S7netplus Plc instance per PLC serialized with SemaphoreSlim — the S7 CPU's comm mailbox is scanned at most once per cycle, so parallel reads don't help |
| AB CIP | Driver.AbCip |
A | libplctag CIP | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | ControlLogix / CompactLogix. Tag discovery uses the @tags walker to enumerate controller-scoped + program-scoped symbols; UDT member resolution via the UDT template reader |
| AB Legacy | Driver.AbLegacy |
A | libplctag PCCC | IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver | SLC 500 / MicroLogix. File-based addressing (N7:0, F8:0) — no symbol table, tag list is user-authored in the config DB |
| TwinCAT | Driver.TwinCAT |
B | Beckhoff TwinCAT.Ads (TcAdsClient) |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IRediscoverable | The only native-notification driver outside Galaxy — ADS delivers ValueChangedCallback events the driver forwards straight to ISubscribable.OnDataChange without polling. Symbol tree uploaded via SymbolLoaderFactory |
| FOCAS | Driver.FOCAS |
A | Pure-managed FocasWireClient — FOCAS/2 Ethernet binary protocol on TCP:8193, inlined into the driver assembly |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe, IPerCallHostResolver, IAlarmSource | IWritable is implemented but read-only by design — WriteAsync returns BadNotWritable for every point. CNC-shaped data model (axes, spindle, PMC, macros, alarms) not a flat tag map. Previously Tier-C (Host + P/Invoke + shim DLL); retired in the 2026-04-24 migration when the managed wire client landed |
| OPC UA Client | Driver.OpcUaClient |
B | OPCFoundation Opc.Ua.Client |
IDriver, ITagDiscovery, IReadable, IWritable, ISubscribable, IAlarmSource, IHistoryProvider, IHostConnectivityProbe | Gateway/aggregation driver — the only driver implementing driver-side IHistoryProvider (forwards HistoryRead to the upstream server). Opens a single Session against a remote OPC UA server and re-exposes its address space. Owns its own ApplicationConfiguration (distinct from Client.Shared) because it's always-on with keep-alive + TransferSubscriptions across SDK reconnect, not an interactive CLI |
| MQTT | Driver.Mqtt (+ .Browser, .Contracts) |
A | MQTTnet 5 | IDriver, ITagDiscovery, IReadable, ISubscribable, IHostConnectivityProbe, IRediscoverable | Push, not poll, and read-only — the broker delivers PUBLISH frames the driver forwards straight to ISubscribable.OnDataChange; IReadable serves the last retained/received value from cache, and there is no IWritable (nothing publishes back). Subscriptions are indexed by topic filter, not by topic, so wildcard tags survive a reconnect. A rejected CONNACK throws MqttConnectRejectedException: unrecoverable codes → Faulted + supervisor stop, transient → retry. Sparkplug B is P2 (mode: SparkplugB is a placeholder) |
| Historian.Gateway | Driver.Historian.Gateway |
— | ZB.MOM.WW.HistorianGateway.Client gRPC (historian_gateway.v1) |
IHistorianDataSource (server-side read backend) + alarm SendEvent writer + WriteLiveValues recorder + IHistorianProvisioning |
Not a tag driver — the sole historian backend. Registers GatewayHistorianDataSource : IHistorianDataSource for HistoryRead and serves alarm-write + continuous historization through the gateway. No IDriver/ITagDiscovery surface. (The retired Wonderware sidecar backend it replaced is documented at Historian.Wonderware.md.) |
Per-driver documentation
-
Galaxy has its own docs in this folder because the gRPC-to-gateway architecture + MXAccess rules (owned by the gateway) + Galaxy Repository SQL + Historian + runtime probe manager don't fit a single table row:
- Galaxy.md — gateway gRPC bridge, hierarchy source, runtime probes
- Galaxy-Repository.md — ZB SQL reader,
LocalPlatformscope filter, change detection (v1 archive)
-
FOCAS has a short getting-started doc because the backend-selection env var + alarm projection opt-in need explaining up front:
- FOCAS.md — deployment, config, capability surface, alarm projection, troubleshooting
-
Modbus TCP, AB CIP, AB Legacy, Siemens S7, TwinCAT, OPC UA Client, and MQTT each have a per-driver overview page:
- Modbus.md — in-process Modbus-TCP driver: address formats, polled subscription model, DL205 octal mapping
- AbCip.md — AB CIP / EtherNet-IP driver (ControlLogix / CompactLogix / Micro800 / GuardLogix): tag discovery, UDT resolution, alarm source
- AbLegacy.md — AB Legacy PCCC driver (SLC 500 / MicroLogix / PLC-5): file-based addressing, user-authored tag list
- S7.md — Siemens S7 driver (S7-300/400/1200/1500 + S7-200): getting started, config, data-block addressing, serialized single-connection model
- TwinCAT.md — Beckhoff TwinCAT (ADS) driver: getting started, native-notification subscription, symbol-tree upload
- OpcUaClient.md — OPC UA Client (gateway/aggregation) driver: remote-server session, driver-side HistoryRead forwarding, reconnect behaviour
- Mqtt.md — MQTT broker-subscribe driver: broker/TLS/auth config, topic + JSON-path tag binding, retained-value seeding,
#-observation browser, CONNACK-rejection semantics
-
Historian.Gateway (server-side historian backend, not a tag driver) is documented in the main guide:
- ../Historian.md — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (
SendEvent), continuous historization (WriteLiveValues),EnsureTagsprovisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: Historian.Wonderware.md.)
- ../Historian.md — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (
-
The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in docs/v2/driver-specs.md. The overview pages above are the short path; that file is the authoritative per-driver reference.
Test-fixture coverage maps
Each driver has a dedicated fixture doc that lays out what the integration / unit harness actually covers vs. what's trusted from field deployments. Read the relevant one before claiming "green suite = production-ready" for a driver.
- AB CIP — Dockerized
ab_server(multi-stage build from libplctag source); atomic-read smoke across 4 families; UDT / ALMD / family quirks unit-only - Modbus — Dockerized
pymodbus+ per-family JSON profiles (4 compose profiles); best-covered driver, gaps are error-path-shaped - Siemens S7 — Dockerized
python-snap7server; DB/MB read + write round-trip verified end-to-end on:1102 - AB Legacy — Dockerized
ab_serverPCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end./1,0cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (B3:0/5) still surface BadState — real HW / RSEmulate 500 for those - TwinCAT — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via
FakeTwinCATClientwith native-notification harness - FOCAS — no integration fixture, unit-only via
FakeFocasClient; Tier C out-of-process isolation scoped but not shipped - OPC UA Client — Dockerized
opc-plcintegration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mockedSession - MQTT — Dockerized
eclipse-mosquittowith TLS + real auth on both listeners (no anonymous fallback) + a JSON-publisher sidecar; env-gated live suite (7 tests) covers TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, and wrong-password rejection. Sparkplug B has no fixture yet (P2) - Galaxy — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
Related cross-driver docs
- HistoricalDataAccess.md —
IHistoryProviderdispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-sideIHistoryProvider(it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backedIHistorianDataSourceinstead. Other drivers do not implement the interface and returnBadHistoryOperationUnsupported. - AlarmTracking.md —
IAlarmSourceevent model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source. - Subscriptions.md — how the Server multiplexes subscriptions onto
ISubscribable.OnDataChange. - docs/v2/driver-stability.md — tier system (A / B / C), shared
CapabilityPolicydefaults per tier × capability,MemoryTrackinghybrid formula, and process-level recycle rules. - docs/v2/plan.md — authoritative vision, architecture decisions, migration strategy.