Files
lmxopcua/tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests/S7DiscoveryAndSubscribeTests.cs
Joseph Doherty d1699af609 Auto: s7-a1 — 64-bit scalar types
Closes the NotSupportedException cliff for S7 Float64/Int64/UInt64.

- S7Size enum gains LWord (8 bytes); parser accepts DBLD/DBL on data
  blocks and LD on M/I/Q (e.g. DB1.DBLD0, DB1.DBL8, MLD0, ILD8, QLD16).
- S7Driver.ReadOneAsync / WriteOneAsync issue ReadBytesAsync /
  WriteBytesAsync for 64-bit types and convert big-endian via
  System.Buffers.Binary.BinaryPrimitives. S7's wire format is BE.
- Internal MapArea(S7Area) helper translates to S7.Net DataType.
- MapDataType now surfaces native DriverDataType for Int16/UInt16/
  UInt32/Int64/UInt64 instead of collapsing them all to Int32.

Tests: parser theories cover DBLD/DBL/MLD/ILD/QLD; discovery test
asserts the 64-bit DriverDataType mapping. 64/64 passing.

Closes #287
2026-04-25 16:16:23 -04:00

167 lines
7.6 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7.Tests;
/// <summary>
/// Shape tests for <see cref="S7Driver"/>'s <see cref="ITagDiscovery"/>,
/// <see cref="ISubscribable"/>, and <see cref="IHostConnectivityProbe"/> surfaces that
/// don't need a live PLC. Wire-level polling round-trips and probe transitions land in a
/// follow-up PR once we have a mock S7 server.
/// </summary>
[Trait("Category", "Unit")]
public sealed class S7DiscoveryAndSubscribeTests
{
private sealed class RecordingAddressSpaceBuilder : IAddressSpaceBuilder
{
public readonly List<string> Folders = new();
public readonly List<(string Name, DriverAttributeInfo Attr)> Variables = new();
public IAddressSpaceBuilder Folder(string browseName, string displayName)
{
Folders.Add(browseName);
return this;
}
public IVariableHandle Variable(string browseName, string displayName, DriverAttributeInfo attributeInfo)
{
Variables.Add((browseName, attributeInfo));
return new StubHandle();
}
public void AddProperty(string browseName, DriverDataType dataType, object? value) { }
public void AttachAlarmCondition(IVariableHandle sourceVariable, string alarmName, DriverAttributeInfo alarmInfo) { }
private sealed class StubHandle : IVariableHandle
{
public string FullReference => "stub";
public IAlarmConditionSink MarkAsAlarmCondition(AlarmConditionInfo info)
=> throw new NotImplementedException("S7 driver never calls this — no alarm surfacing");
}
}
[Fact]
public async Task DiscoverAsync_projects_every_tag_into_the_address_space()
{
var opts = new S7DriverOptions
{
Host = "192.0.2.1",
Tags =
[
new("TempSetpoint", "DB1.DBW0", S7DataType.Int16, Writable: true),
new("FaultBit", "M0.0", S7DataType.Bool, Writable: false),
new("PIDOutput", "DB5.DBD12", S7DataType.Float32, Writable: true),
],
};
using var drv = new S7Driver(opts, "s7-disco");
var builder = new RecordingAddressSpaceBuilder();
await drv.DiscoverAsync(builder, TestContext.Current.CancellationToken);
builder.Folders.ShouldContain("S7");
builder.Variables.Count.ShouldBe(3);
builder.Variables[0].Name.ShouldBe("TempSetpoint");
builder.Variables[0].Attr.SecurityClass.ShouldBe(SecurityClassification.Operate, "writable tags get Operate security class");
builder.Variables[1].Attr.SecurityClass.ShouldBe(SecurityClassification.ViewOnly, "read-only tags get ViewOnly");
builder.Variables[2].Attr.DriverDataType.ShouldBe(DriverDataType.Float32);
}
[Fact]
public async Task DiscoverAsync_maps_64bit_types_to_matching_DriverDataType()
{
// PR-S7-A1: 64-bit scalar types must surface with their native DriverDataType
// (not collapse to Int32) so the OPC UA address-space layer publishes the right
// BuiltInType. Address suffixes: DBLD (DB long-DWord), MLD/ILD/QLD (M/I/Q long-DWord).
var opts = new S7DriverOptions
{
Host = "192.0.2.1",
Tags =
[
new("BigInt", "DB1.DBLD0", S7DataType.Int64),
new("BigUInt", "DB1.DBLD8", S7DataType.UInt64),
new("BigDouble", "DB1.DBLD16", S7DataType.Float64),
new("MerkerLong", "MLD0", S7DataType.Int64),
],
};
using var drv = new S7Driver(opts, "s7-64bit");
var builder = new RecordingAddressSpaceBuilder();
await drv.DiscoverAsync(builder, TestContext.Current.CancellationToken);
builder.Variables.Single(v => v.Name == "BigInt").Attr.DriverDataType.ShouldBe(DriverDataType.Int64);
builder.Variables.Single(v => v.Name == "BigUInt").Attr.DriverDataType.ShouldBe(DriverDataType.UInt64);
builder.Variables.Single(v => v.Name == "BigDouble").Attr.DriverDataType.ShouldBe(DriverDataType.Float64);
builder.Variables.Single(v => v.Name == "MerkerLong").Attr.DriverDataType.ShouldBe(DriverDataType.Int64);
}
[Fact]
public async Task DiscoverAsync_propagates_WriteIdempotent_from_tag_to_attribute_info()
{
var opts = new S7DriverOptions
{
Host = "192.0.2.1",
Tags =
[
new("SetPoint", "DB1.DBW0", S7DataType.Int16, WriteIdempotent: true),
new("StartBit", "M0.0", S7DataType.Bool),
],
};
using var drv = new S7Driver(opts, "s7-idem");
var builder = new RecordingAddressSpaceBuilder();
await drv.DiscoverAsync(builder, TestContext.Current.CancellationToken);
builder.Variables.Single(v => v.Name == "SetPoint").Attr.WriteIdempotent.ShouldBeTrue();
builder.Variables.Single(v => v.Name == "StartBit").Attr.WriteIdempotent.ShouldBeFalse("default is opt-in per decision #44");
}
[Fact]
public void GetHostStatuses_returns_one_row_with_host_port_identity_pre_init()
{
var opts = new S7DriverOptions { Host = "plc1.internal", Port = 102 };
using var drv = new S7Driver(opts, "s7-host");
var rows = drv.GetHostStatuses();
rows.Count.ShouldBe(1);
rows[0].HostName.ShouldBe("plc1.internal:102");
rows[0].State.ShouldBe(HostState.Unknown, "pre-init / pre-probe state is Unknown");
}
[Fact]
public async Task SubscribeAsync_returns_unique_handles_and_UnsubscribeAsync_accepts_them()
{
var opts = new S7DriverOptions { Host = "192.0.2.1" };
using var drv = new S7Driver(opts, "s7-sub");
// SubscribeAsync does not itself call ReadAsync (the poll task does), so this works
// even though the driver isn't initialized. The poll task catches the resulting
// InvalidOperationException and the loop quietly continues — same pattern as the
// Modbus driver's poll loop tolerating transient transport failures.
var h1 = await drv.SubscribeAsync(["T1"], TimeSpan.FromMilliseconds(200), TestContext.Current.CancellationToken);
var h2 = await drv.SubscribeAsync(["T2"], TimeSpan.FromMilliseconds(200), TestContext.Current.CancellationToken);
h1.DiagnosticId.ShouldStartWith("s7-sub-");
h2.DiagnosticId.ShouldStartWith("s7-sub-");
h1.DiagnosticId.ShouldNotBe(h2.DiagnosticId);
await drv.UnsubscribeAsync(h1, TestContext.Current.CancellationToken);
await drv.UnsubscribeAsync(h2, TestContext.Current.CancellationToken);
// UnsubscribeAsync with an unknown handle must be a no-op, not throw.
await drv.UnsubscribeAsync(h1, TestContext.Current.CancellationToken);
}
[Fact]
public async Task Subscribe_publishing_interval_is_floored_at_100ms()
{
var opts = new S7DriverOptions { Host = "192.0.2.1", Probe = new S7ProbeOptions { Enabled = false } };
using var drv = new S7Driver(opts, "s7-floor");
// 50 ms requested — the floor protects the S7 CPU from sub-scan polling that would
// just queue wire-side. Test that the subscription is accepted (the floor is applied
// internally; the floor value isn't exposed, so we're really just asserting that the
// driver doesn't reject small intervals).
var h = await drv.SubscribeAsync(["T"], TimeSpan.FromMilliseconds(50), TestContext.Current.CancellationToken);
h.ShouldNotBeNull();
await drv.UnsubscribeAsync(h, TestContext.Current.CancellationToken);
}
}