Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests/AbLegacyArrayTests.cs
T

372 lines
17 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Tests;
/// <summary>
/// Phase 4c #137 array support for the AbLegacy (PCCC/DF1) driver. A PCCC data file
/// (e.g. <c>N7</c>) is inherently an array of up to 256 words; an equipment tag carrying an
/// <c>arrayLength</c> reads <c>count</c> consecutive file elements from the base address
/// (<c>N7:0</c> reading <c>count</c> words) via libplctag's native element-count and surfaces
/// them as a typed CLR array. Proven here against <see cref="FakeAbLegacyTag"/>; there is no
/// live AbLegacy fixture on this machine.
/// </summary>
[Trait("Category", "Unit")]
public sealed class AbLegacyArrayTests
{
private static (AbLegacyDriver drv, FakeAbLegacyTagFactory factory) NewDriver(params AbLegacyTagDefinition[] tags)
{
var factory = new FakeAbLegacyTagFactory();
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
{
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0")],
Tags = tags,
Probe = new AbLegacyProbeOptions { Enabled = false },
}, "ablegacy-array", factory);
return (drv, factory);
}
// ---- Read: typed CLR arrays ----
/// <summary>An N-file (16-bit integer) array tag reads a <c>short[]</c>.</summary>
[Fact]
public async Task Read_N_file_array_returns_short_array()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Levels", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 5));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new short[] { 100, 101, 102, 103, 104 } };
var snapshots = await drv.ReadAsync(["Levels"], CancellationToken.None);
snapshots.Single().StatusCode.ShouldBe(AbLegacyStatusMapper.Good);
var arr = snapshots.Single().Value.ShouldBeOfType<short[]>();
arr.ShouldBe(new short[] { 100, 101, 102, 103, 104 });
}
/// <summary>An L-file (32-bit long) array tag reads an <c>int[]</c>.</summary>
[Fact]
public async Task Read_L_file_array_returns_int_array()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Counts", "ab://10.0.0.5/1,0", "L9:0", AbLegacyDataType.Long, ArrayLength: 3));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new[] { 70000, 80000, 90000 } };
var snapshots = await drv.ReadAsync(["Counts"], CancellationToken.None);
var arr = snapshots.Single().Value.ShouldBeOfType<int[]>();
arr.ShouldBe(new[] { 70000, 80000, 90000 });
}
/// <summary>An F-file (32-bit float) array tag reads a <c>float[]</c>.</summary>
[Fact]
public async Task Read_F_file_array_returns_float_array()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Temps", "ab://10.0.0.5/1,0", "F8:0", AbLegacyDataType.Float, ArrayLength: 4));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new[] { 1.5f, 2.5f, 3.5f, 4.5f } };
var snapshots = await drv.ReadAsync(["Temps"], CancellationToken.None);
var arr = snapshots.Single().Value.ShouldBeOfType<float[]>();
arr.ShouldBe(new[] { 1.5f, 2.5f, 3.5f, 4.5f });
}
/// <summary>A B-file (bit) array tag reads a <c>bool[]</c>.</summary>
[Fact]
public async Task Read_B_file_array_returns_bool_array()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Flags", "ab://10.0.0.5/1,0", "B3:0", AbLegacyDataType.Bit, ArrayLength: 6));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new[] { true, false, true, false, true, false } };
var snapshots = await drv.ReadAsync(["Flags"], CancellationToken.None);
var arr = snapshots.Single().Value.ShouldBeOfType<bool[]>();
arr.ShouldBe(new[] { true, false, true, false, true, false });
}
/// <summary>The element count flows into the create params so libplctag reads N words.</summary>
[Fact]
public async Task Array_tag_threads_element_count_into_create_params()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Levels", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 5));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new short[] { 1, 2, 3, 4, 5 } };
await drv.ReadAsync(["Levels"], CancellationToken.None);
factory.Tags["N7:0"].CreationParams.ElementCount.ShouldBe(5);
}
/// <summary>A read failure on an array tag surfaces the mapped Bad status, not a partial array.</summary>
[Fact]
public async Task Array_read_failure_surfaces_bad_status()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Levels", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 5));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { Status = (int)libplctag.Status.ErrorTimeout };
var snapshots = await drv.ReadAsync(["Levels"], CancellationToken.None);
snapshots.Single().Value.ShouldBeNull();
snapshots.Single().StatusCode.ShouldNotBe(AbLegacyStatusMapper.Good);
}
// ---- Scalar regression ----
/// <summary>A scalar tag (no ArrayLength) still reads a single value, not an array.</summary>
[Fact]
public async Task Scalar_tag_still_reads_single_value()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Counter", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { Value = 42 };
var snapshots = await drv.ReadAsync(["Counter"], CancellationToken.None);
snapshots.Single().Value.ShouldBe(42);
snapshots.Single().Value.ShouldNotBeOfType<short[]>();
factory.Tags["N7:0"].CreationParams.ElementCount.ShouldBe(1);
}
/// <summary>
/// A 1-element array (ArrayLength: 1) reads as a 1-element typed array, NOT a scalar.
/// The foundation materialises a <c>[1]</c> OPC UA array node for <c>isArray:true,
/// arrayLength:1</c>, so the driver read must return a single-element array to match
/// (review I-3). ElementCount stays 1.
/// </summary>
[Fact]
public async Task ArrayLength_of_one_reads_a_one_element_array()
{
var (drv, factory) = NewDriver(
new AbLegacyTagDefinition("Counter", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 1));
await drv.InitializeAsync("{}", CancellationToken.None);
factory.Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new short[] { 7 } };
var snapshots = await drv.ReadAsync(["Counter"], CancellationToken.None);
var arr = snapshots.Single().Value.ShouldBeOfType<short[]>();
arr.ShouldBe(new short[] { 7 });
factory.Tags["N7:0"].CreationParams.ElementCount.ShouldBe(1);
}
// ---- Discovery ----
/// <summary>Discovery flips IsArray and surfaces ArrayDim for an array file tag.</summary>
[Fact]
public async Task Discovery_surfaces_IsArray_and_ArrayDim_for_array_tag()
{
var captured = new List<DriverAttributeInfo>();
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
{
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0")],
Tags = [new AbLegacyTagDefinition("Vector", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 8)],
Probe = new AbLegacyProbeOptions { Enabled = false },
}, "ablegacy-array", new FakeAbLegacyTagFactory());
await drv.InitializeAsync("{}", CancellationToken.None);
await drv.DiscoverAsync(new RecordingBuilder(captured), CancellationToken.None);
captured.Count.ShouldBe(1);
captured[0].IsArray.ShouldBeTrue();
captured[0].ArrayDim.ShouldBe(8u);
}
/// <summary>
/// I-3: a 1-element array tag (ArrayLength: 1) discovers as IsArray=true / ArrayDim=1 —
/// a <c>[1]</c> OPC UA array node, not a scalar.
/// </summary>
[Fact]
public async Task Discovery_surfaces_one_element_array_as_IsArray_with_dim_one()
{
var captured = new List<DriverAttributeInfo>();
var (drv, _) = NewDriver(
new AbLegacyTagDefinition("Single", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 1));
await drv.InitializeAsync("{}", CancellationToken.None);
await drv.DiscoverAsync(new RecordingBuilder(captured), CancellationToken.None);
captured[0].IsArray.ShouldBeTrue();
captured[0].ArrayDim.ShouldBe(1u);
}
/// <summary>Scalar tag discovery keeps IsArray false / ArrayDim null (regression guard).</summary>
[Fact]
public async Task Discovery_keeps_scalar_tag_non_array()
{
var captured = new List<DriverAttributeInfo>();
var (drv, _) = NewDriver(
new AbLegacyTagDefinition("Single", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int));
await drv.InitializeAsync("{}", CancellationToken.None);
await drv.DiscoverAsync(new RecordingBuilder(captured), CancellationToken.None);
captured[0].IsArray.ShouldBeFalse();
captured[0].ArrayDim.ShouldBeNull();
}
/// <summary>Discovery caps a 1024-element tag's ArrayDim at the PCCC 256-word file maximum.</summary>
[Fact]
public async Task Discovery_caps_array_dim_at_256()
{
var captured = new List<DriverAttributeInfo>();
var (drv, _) = NewDriver(
new AbLegacyTagDefinition("Big", "ab://10.0.0.5/1,0", "N7:0", AbLegacyDataType.Int, ArrayLength: 1024));
await drv.InitializeAsync("{}", CancellationToken.None);
await drv.DiscoverAsync(new RecordingBuilder(captured), CancellationToken.None);
captured[0].IsArray.ShouldBeTrue();
captured[0].ArrayDim.ShouldBe(256u);
}
// ---- Equipment-tag resolver threads arrayLength ----
/// <summary>The equipment-tag parser threads <c>arrayLength</c> into the transient definition.</summary>
[Fact]
public void EquipmentTagParser_threads_arrayLength()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":true,"arrayLength":10}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBe(10);
}
/// <summary>The parser caps <c>arrayLength</c> at the PCCC 256-word file maximum (isArray:true).</summary>
[Fact]
public void EquipmentTagParser_caps_arrayLength_at_256()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":true,"arrayLength":99999}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBe(256);
}
/// <summary>A scalar equipment tag (no arrayLength) leaves ArrayLength null.</summary>
[Fact]
public void EquipmentTagParser_scalar_leaves_arrayLength_null()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int"}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBeNull();
}
/// <summary>
/// C-2 regression: an <c>arrayLength</c> WITHOUT <c>isArray:true</c> is a SCALAR. The
/// canonical contract gates an array on <c>isArray:true</c>, so a stale length behind a
/// cleared / absent isArray must leave ArrayLength null and never produce an orphan array.
/// </summary>
[Fact]
public void EquipmentTagParser_arrayLength_without_isArray_is_scalar()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","arrayLength":8}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBeNull();
}
/// <summary>C-2 regression: <c>isArray:false</c> with a positive arrayLength is a SCALAR.</summary>
[Fact]
public void EquipmentTagParser_isArray_false_with_arrayLength_is_scalar()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":false,"arrayLength":8}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBeNull();
}
/// <summary>
/// I-3: <c>isArray:true, arrayLength:1</c> is a valid 1-element array — ArrayLength is 1
/// (not null), so the foundation materialises a <c>[1]</c> node and the driver reads it
/// as a 1-element array.
/// </summary>
[Fact]
public void EquipmentTagParser_isArray_true_arrayLength_one_is_one_element_array()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":true,"arrayLength":1}""";
AbLegacyEquipmentTagParser.TryParse(json, out var def).ShouldBeTrue();
def!.ArrayLength.ShouldBe(1);
}
/// <summary>
/// End-to-end: an AbLegacy driver with NO authored tags reads an equipment-tag ref whose
/// TagConfig carries <c>isArray:true</c> + <c>arrayLength</c> — the resolver threads the
/// count and the read surfaces a typed array, capping the libplctag element count at 256.
/// </summary>
[Fact]
public async Task Driver_reads_equipment_array_ref_as_typed_array()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":true,"arrayLength":3}""";
var factory = new FakeAbLegacyTagFactory { Customise = p => new FakeAbLegacyTag(p) { ArrayValue = new short[] { 11, 22, 33 } } };
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
{
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0")],
Tags = [],
Probe = new AbLegacyProbeOptions { Enabled = false },
}, "ablegacy-eq-array", factory);
await drv.InitializeAsync("{}", CancellationToken.None);
var r = await drv.ReadAsync([json], CancellationToken.None);
r[0].StatusCode.ShouldBe(AbLegacyStatusMapper.Good);
var arr = r[0].Value.ShouldBeOfType<short[]>();
arr.ShouldBe(new short[] { 11, 22, 33 });
factory.Tags["N7:0"].CreationParams.ElementCount.ShouldBe(3);
}
/// <summary>
/// C-2 end-to-end: an equipment-tag ref carrying <c>isArray:false, arrayLength:8</c> reads
/// a single SCALAR value (the parser drops the orphan length), so the read never decodes a
/// phantom 8-element array against a scalar node. ElementCount stays 1.
/// </summary>
[Fact]
public async Task Driver_reads_isArray_false_with_arrayLength_as_scalar()
{
var json = """{"deviceHostAddress":"ab://10.0.0.5/1,0","address":"N7:0","dataType":"Int","isArray":false,"arrayLength":8}""";
var factory = new FakeAbLegacyTagFactory { Customise = p => new FakeAbLegacyTag(p) { Value = 99 } };
var drv = new AbLegacyDriver(new AbLegacyDriverOptions
{
Devices = [new AbLegacyDeviceOptions("ab://10.0.0.5/1,0")],
Tags = [],
Probe = new AbLegacyProbeOptions { Enabled = false },
}, "ablegacy-eq-scalar", factory);
await drv.InitializeAsync("{}", CancellationToken.None);
var r = await drv.ReadAsync([json], CancellationToken.None);
r[0].StatusCode.ShouldBe(AbLegacyStatusMapper.Good);
r[0].Value.ShouldBe(99);
r[0].Value.ShouldNotBeOfType<short[]>();
factory.Tags["N7:0"].CreationParams.ElementCount.ShouldBe(1);
}
private sealed class RecordingBuilder(List<DriverAttributeInfo> captured) : IAddressSpaceBuilder
{
public IAddressSpaceBuilder Folder(string browseName, string displayName) => this;
public IVariableHandle Variable(string browseName, string displayName, DriverAttributeInfo info)
{
captured.Add(info);
return new Handle(info.FullName);
}
public void AddProperty(string name, DriverDataType dataType, object? value) { }
private sealed class Handle(string fullRef) : IVariableHandle
{
public string FullReference => fullRef;
public IAlarmConditionSink MarkAsAlarmCondition(AlarmConditionInfo info) => new NullSink();
}
private sealed class NullSink : IAlarmConditionSink
{
public void OnTransition(AlarmEventArgs args) { }
}
}
}