Joseph Doherty 7ba783de77 Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three
non-Galaxy driver factories so a Config DB `DriverType` in
{`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of
being silently skipped by DriverInstanceBootstrapper.

Each factory follows the same shape as ModbusDriverFactoryExtensions +
the existing Galaxy + FOCAS patterns:
 - Static `Register(DriverFactoryRegistry)` entry point.
 - Internal `CreateInstance(driverInstanceId, driverConfigJson)` —
   deserialises a DTO, strict-parses enum fields (fail-fast with an
   explicit "expected one of" list), composes the driver's options object,
   returns a new driver.
 - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at
   the registry layer).

DTO surfaces cover every option the respective driver's Options class
exposes — devices, tags, probe, timeouts, per-driver quirks
(AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/
CpuType, AbLegacy PlcFamily).

Seed SQL (mirrors `seed-modbus-smoke.sql` shape):
 - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device +
   `TestDINT:DInt` tag, pointing at the ab_server compose fixture
   (`ab://127.0.0.1:44818/1,0`).
 - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16`
   tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port).
 - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5`
   tag. Hardware-gated per #222; placeholder gateway to be replaced with
   real SLC/MicroLogix/PLC-5/RSEmulate before running.

Build plumbing:
 - Each driver project now ProjectReferences `Core` (was
   `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting`
   so the factory extensions can't compile without it. Matches the FOCAS +
   Galaxy.Proxy reference shape.
 - `Server.csproj` adds the three new driver ProjectReferences so Program.cs
   resolves the symbols at compile-time + ships the assemblies at runtime.

Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only.

Live boot verification of all four (Modbus + these three) happens in the
exit-gate PR — factories + seeds are pre-conditions and are being
shipped first so the exit-gate PR can scope to "does the server publish
the expected NodeIds + does the e2e script pass."

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:15:38 -04:00
..
Phase 3 PR 63 -- S7AddressParser for DB/M/I/Q/T/C address strings. Adds S7AddressParser + S7ParsedAddress + S7Area + S7Size to the Driver.S7 project. Grammar follows driver-specs.md \u00A75 + Siemens TIA Portal / STEP 7 Classic convention: (1) Data blocks: DB{n}.DB{X|B|W|D}{offset}[.bit] where X=bit (requires .bit suffix 0-7), B=byte, W=word (16-bit), D=dword (32-bit). (2) Merkers: MB{n}, MW{n}, MD{n}, or M{n}.{bit} for bit access. (3) Inputs + Outputs: same {B|W|D} prefix or {n}.{bit} pattern as M. (4) Timers: T{n}. (5) Counters: C{n}. Output is an immutable S7ParsedAddress record struct with Area (DataBlock / Memory / Input / Output / Timer / Counter), DbNumber (only meaningful for DataBlock), Size (Bit / Byte / Word / DWord), ByteOffset (also timer/counter number when Area is Timer/Counter), BitOffset (0-7 for Size=Bit; 0 otherwise). Case-insensitive via ToUpperInvariant, whitespace trimmed on entry. Parse throws FormatException with the offending input echoed in the message; TryParse returns bool for config-validation callers that can't afford exceptions (e.g. Admin UI tag-editor live validation). Strict rejection policy -- 16 garbage cases covered in the theory test: empty/whitespace input, unknown area letter (Z0), DB without number/tail, DB bit size without .bit suffix, bit offset 8+, word/dword with .bit suffix, DB number 0 (must be >=1), non-numeric DB number, unknown size letter (Q), M without offset, M bit access without .bit, bit 8, negative offset, non-digit offset, non-numeric timer. Strict rejection surfaces config errors at driver-init time rather than as BadInternalError on every Read against the bad tag. No driver code wires through yet -- PR 64 is where IReadable/IWritable consume S7ParsedAddress and translate into S7netplus Plc.ReadAsync calls (the S7.Net address grammar is a strict subset of what we accept, and the parser's S7ParsedAddress is the bridge). Unit tests (S7AddressParserTests, 50 facts): parse-valid theories for DB/M/I/Q/T/C covering all size variants + edge bit offsets 0 and 7; case-insensitive + whitespace-trim theory; reject-invalid theory with 16 garbage cases; TryParse round-trip for valid and invalid inputs. 50/50 pass, dotnet build clean.