FocasDataType.String was authorable on any address, but no area read returns text: PMC fell through to a byte read, PARAM to Int32, MACRO to a double, and the String node received a boxed number at Good. One rule, FocasTagDefinitionFactory.DescribeDataTypeMismatch, now backs every path: - FromTagConfig rejects the pair, so the driver skips + reports it (BadNodeIdUnknown, never a Good number) and Inspect names the reason at deploy; - FocasTagConfigModel.Validate refuses it on the typed fields; - the AdminUI editor only offers String where it is readable and shows the rule's text inline (kept visible for a loaded blob that already carries it); - the CLI read/subscribe/probe/write commands refuse it at the boundary. String stays valid on FIXED: paths (Identity/Program name/mode text) and is ignored on ALARM: tags; an unparseable address keeps its own diagnosis. Razor change (FocasTagConfigEditor.razor) needs the Wave 4 live check. Refs #740 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT