Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Host/Domain/IMxProxy.cs
Joseph Doherty 3b2defd94f Phase 0 — mechanical rename ZB.MOM.WW.LmxOpcUa.* → ZB.MOM.WW.OtOpcUa.*
Renames all 11 projects (5 src + 6 tests), the .slnx solution file, all source-file namespaces, all axaml namespace references, and all v1 documentation references in CLAUDE.md and docs/*.md (excluding docs/v2/ which is already in OtOpcUa form). Also updates the TopShelf service registration name from "LmxOpcUa" to "OtOpcUa" per Phase 0 Task 0.6.

Preserves runtime identifiers per Phase 0 Out-of-Scope rules to avoid breaking v1/v2 client trust during coexistence: OPC UA `ApplicationUri` defaults (`urn:{GalaxyName}:LmxOpcUa`), server `EndpointPath` (`/LmxOpcUa`), `ServerName` default (feeds cert subject CN), `MxAccessConfiguration.ClientName` default (defensive — stays "LmxOpcUa" for MxAccess audit-trail consistency), client OPC UA identifiers (`ApplicationName = "LmxOpcUaClient"`, `ApplicationUri = "urn:localhost:LmxOpcUaClient"`, cert directory `%LocalAppData%\LmxOpcUaClient\pki\`), and the `LmxOpcUaServer` class name (class rename out of Phase 0 scope per Task 0.5 sed pattern; happens in Phase 1 alongside `LmxNodeManager → GenericDriverNodeManager` Core extraction). 23 LmxOpcUa references retained, all enumerated and justified in `docs/v2/implementation/exit-gate-phase-0.md`.

Build clean: 0 errors, 30 warnings (lower than baseline 167). Tests at strict improvement over baseline: 821 passing / 1 failing vs baseline 820 / 2 (one flaky pre-existing failure passed this run; the other still fails — both pre-existing and unrelated to the rename). `Client.UI.Tests`, `Historian.Aveva.Tests`, `Client.Shared.Tests`, `IntegrationTests` all match baseline exactly. Exit gate compliance results recorded in `docs/v2/implementation/exit-gate-phase-0.md` with all 7 checks PASS or DEFERRED-to-PR-review (#7 service install verification needs Windows service permissions on the reviewer's box).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-17 13:57:47 -04:00

99 lines
4.7 KiB
C#

using ArchestrA.MxAccess;
namespace ZB.MOM.WW.OtOpcUa.Host.Domain
{
/// <summary>
/// Delegate matching LMXProxyServer.OnDataChange COM event signature.
/// </summary>
/// <param name="hLMXServerHandle">The runtime connection handle that raised the change.</param>
/// <param name="phItemHandle">The runtime item handle for the attribute that changed.</param>
/// <param name="pvItemValue">The new raw runtime value for the attribute.</param>
/// <param name="pwItemQuality">The OPC DA quality code supplied by the runtime.</param>
/// <param name="pftItemTimeStamp">The timestamp object supplied by the runtime for the value.</param>
/// <param name="ItemStatus">The MXAccess status payload associated with the callback.</param>
public delegate void MxDataChangeHandler(
int hLMXServerHandle,
int phItemHandle,
object pvItemValue,
int pwItemQuality,
object pftItemTimeStamp,
ref MXSTATUS_PROXY[] ItemStatus);
/// <summary>
/// Delegate matching LMXProxyServer.OnWriteComplete COM event signature.
/// </summary>
/// <param name="hLMXServerHandle">The runtime connection handle that processed the write.</param>
/// <param name="phItemHandle">The runtime item handle that was written.</param>
/// <param name="ItemStatus">The MXAccess status payload describing the write outcome.</param>
public delegate void MxWriteCompleteHandler(
int hLMXServerHandle,
int phItemHandle,
ref MXSTATUS_PROXY[] ItemStatus);
/// <summary>
/// Abstraction over LMXProxyServer COM object to enable testing without the COM runtime. (MXA-001)
/// </summary>
public interface IMxProxy
{
/// <summary>
/// Registers the bridge as an MXAccess client with the runtime proxy.
/// </summary>
/// <param name="clientName">The client identity reported to the runtime for diagnostics and session tracking.</param>
/// <returns>The runtime connection handle assigned to the client session.</returns>
int Register(string clientName);
/// <summary>
/// Unregisters the bridge from the runtime proxy and releases the connection handle.
/// </summary>
/// <param name="handle">The connection handle returned by <see cref="Register(string)" />.</param>
void Unregister(int handle);
/// <summary>
/// Adds a Galaxy attribute reference to the active runtime session.
/// </summary>
/// <param name="handle">The runtime connection handle.</param>
/// <param name="address">The fully qualified attribute reference to resolve.</param>
/// <returns>The runtime item handle assigned to the attribute.</returns>
int AddItem(int handle, string address);
/// <summary>
/// Removes a previously registered attribute from the runtime session.
/// </summary>
/// <param name="handle">The runtime connection handle.</param>
/// <param name="itemHandle">The item handle returned by <see cref="AddItem(int, string)" />.</param>
void RemoveItem(int handle, int itemHandle);
/// <summary>
/// Starts supervisory updates for an attribute so runtime changes are pushed to the bridge.
/// </summary>
/// <param name="handle">The runtime connection handle.</param>
/// <param name="itemHandle">The item handle to monitor.</param>
void AdviseSupervisory(int handle, int itemHandle);
/// <summary>
/// Stops supervisory updates for an attribute.
/// </summary>
/// <param name="handle">The runtime connection handle.</param>
/// <param name="itemHandle">The item handle to stop monitoring.</param>
void UnAdviseSupervisory(int handle, int itemHandle);
/// <summary>
/// Writes a new value to a runtime attribute through the COM proxy.
/// </summary>
/// <param name="handle">The runtime connection handle.</param>
/// <param name="itemHandle">The item handle to write.</param>
/// <param name="value">The new value to push into the runtime.</param>
/// <param name="securityClassification">The Wonderware security classification applied to the write.</param>
void Write(int handle, int itemHandle, object value, int securityClassification);
/// <summary>
/// Occurs when the runtime pushes a data-change callback for a subscribed attribute.
/// </summary>
event MxDataChangeHandler? OnDataChange;
/// <summary>
/// Occurs when the runtime acknowledges completion of a write request.
/// </summary>
event MxWriteCompleteHandler? OnWriteComplete;
}
}