UnsTabDragDropE2ETests were timing out at the 'UNS Structure' nav-link locator because AdminWebAppFactory never registered AdminHubConnectionFactory / HubTokenService / DataProtection — ClusterDetail.razor's @inject threw at circuit boot, so the page never advanced past the Loading placeholder. 2 → 3 pass after the registrations land. Also documents the Modbus standard-vs- exception_injection coverage matrix in the fixture README + cross-references docs/drivers/AbServer-Test-Fixture.md from each Emulate test so a developer landing on a skipped test has a direct doc pointer. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
110 lines
5.4 KiB
C#
110 lines
5.4 KiB
C#
using Shouldly;
|
|
using Xunit;
|
|
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.AbCip;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests.Emulate;
|
|
|
|
/// <summary>
|
|
/// Golden-box-tier ALMD alarm projection tests against Logix Emulate.
|
|
/// Promotes the feature-flagged ALMD projection (task #177) from unit-only coverage
|
|
/// (<c>AbCipAlarmProjectionTests</c> with faked InFaulted sequences) to end-to-end
|
|
/// wire-level coverage — Emulate runs the real ALMD instruction, with real
|
|
/// rising-edge semantics on <c>InFaulted</c> + <c>Ack</c>, so the driver's poll-based
|
|
/// projection gets validated against the actual behaviour shops running FT View see.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// <para><b>Required Emulate project state</b> (see <c>LogixProject/README.md</c>):</para>
|
|
/// <list type="bullet">
|
|
/// <item>Controller-scope ALMD tag <c>HighTempAlarm</c> — a standard ALMD instruction
|
|
/// with default member set (<c>In</c>, <c>InFaulted</c>, <c>Acked</c>,
|
|
/// <c>Severity</c>, <c>Cfg_ProgTime</c>, …).</item>
|
|
/// <item>A periodic task that drives <c>HighTempAlarm.In</c> false→true→false at a
|
|
/// cadence the operator can script via a one-shot routine (e.g. a
|
|
/// <c>SimulateAlarm</c> bit the test case pulses through
|
|
/// <c>IWritable.WriteAsync</c>).</item>
|
|
/// <item>Operator writes <c>1</c> to <c>SimulateAlarm</c> to trigger the rising
|
|
/// edge on <c>HighTempAlarm.In</c>; ladder uses that as the alarm input.</item>
|
|
/// </list>
|
|
/// <para>Runs only when <c>AB_SERVER_PROFILE=emulate</c>. ab_server has no ALMD
|
|
/// instruction + no alarm subsystem, so this tier-gated class couldn't produce a
|
|
/// meaningful result against the default simulator.</para>
|
|
/// <para>The Emulate tier is hardware-gated (Rockwell per-seat license, Windows-only,
|
|
/// conflicts with Docker Desktop's WSL 2 backend) so a permanent skip in CI is expected
|
|
/// — see <c>docs/drivers/AbServer-Test-Fixture.md</c> §"Logix Emulate golden-box tier"
|
|
/// for the full rationale + the gap matrix this test closes.</para>
|
|
/// </remarks>
|
|
[Collection("AbServerEmulate")]
|
|
[Trait("Category", "Integration")]
|
|
[Trait("Tier", "Emulate")]
|
|
public sealed class AbCipEmulateAlmdTests
|
|
{
|
|
[AbServerFact]
|
|
public async Task Real_ALMD_raise_fires_OnAlarmEvent_through_the_driver_projection()
|
|
{
|
|
AbServerProfileGate.SkipUnless(AbServerProfileGate.Emulate);
|
|
|
|
var endpoint = Environment.GetEnvironmentVariable("AB_SERVER_ENDPOINT")
|
|
?? throw new InvalidOperationException(
|
|
"AB_SERVER_ENDPOINT must be set to the Logix Emulate instance when AB_SERVER_PROFILE=emulate.");
|
|
|
|
var options = new AbCipDriverOptions
|
|
{
|
|
Devices = [new AbCipDeviceOptions($"ab://{endpoint}/1,0")],
|
|
EnableAlarmProjection = true,
|
|
AlarmPollInterval = TimeSpan.FromMilliseconds(200),
|
|
Tags = [
|
|
new AbCipTagDefinition(
|
|
Name: "HighTempAlarm",
|
|
DeviceHostAddress: $"ab://{endpoint}/1,0",
|
|
TagPath: "HighTempAlarm",
|
|
DataType: AbCipDataType.Structure,
|
|
Members: [
|
|
new AbCipStructureMember("InFaulted", AbCipDataType.DInt),
|
|
new AbCipStructureMember("Acked", AbCipDataType.DInt),
|
|
new AbCipStructureMember("Severity", AbCipDataType.DInt),
|
|
new AbCipStructureMember("In", AbCipDataType.DInt),
|
|
]),
|
|
// The "simulate the alarm input" bit the ladder watches.
|
|
new AbCipTagDefinition(
|
|
Name: "SimulateAlarm",
|
|
DeviceHostAddress: $"ab://{endpoint}/1,0",
|
|
TagPath: "SimulateAlarm",
|
|
DataType: AbCipDataType.Bool,
|
|
Writable: true),
|
|
],
|
|
};
|
|
|
|
await using var drv = new AbCipDriver(options, driverInstanceId: "emulate-almd");
|
|
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
|
|
|
var raised = new TaskCompletionSource<AlarmEventArgs>(TaskCreationOptions.RunContinuationsAsynchronously);
|
|
drv.OnAlarmEvent += (_, e) =>
|
|
{
|
|
if (e.Message.Contains("raised")) raised.TrySetResult(e);
|
|
};
|
|
|
|
var sub = await drv.SubscribeAlarmsAsync(
|
|
["HighTempAlarm"], TestContext.Current.CancellationToken);
|
|
|
|
// Pulse the input bit the ladder watches, then wait for the driver's poll loop
|
|
// to see InFaulted rise + fire the raise event.
|
|
_ = await drv.WriteAsync(
|
|
[new WriteRequest("SimulateAlarm", true)],
|
|
TestContext.Current.CancellationToken);
|
|
|
|
var got = await Task.WhenAny(raised.Task, Task.Delay(TimeSpan.FromSeconds(5)));
|
|
got.ShouldBe(raised.Task, "driver must surface the ALMD raise within 5 s of the ladder-driven edge");
|
|
var args = await raised.Task;
|
|
args.SourceNodeId.ShouldBe("HighTempAlarm");
|
|
args.AlarmType.ShouldBe("ALMD");
|
|
|
|
await drv.UnsubscribeAlarmsAsync(sub, TestContext.Current.CancellationToken);
|
|
|
|
// Reset the bit so the next test run starts from a known state.
|
|
_ = await drv.WriteAsync(
|
|
[new WriteRequest("SimulateAlarm", false)],
|
|
TestContext.Current.CancellationToken);
|
|
}
|
|
}
|