Files
lmxopcua/tests
Joseph Doherty 02a0e8efd1 Phase 3 PR 42 — ModbusPal simulator profiles for Standard Modbus + DL205/DL260 quirks. Two hand-authored .xmpp profiles in tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/ModbusPal/ that integration tests load via the GUI to drive the suite without a real PLC. Both well-formed XML (verified via PowerShell [xml] cast); both copied to test-output as PreserveNewest content per the existing csproj rule.
Standard.xmpp — generic Modbus TCP server on port 502, slave id 1. HR[0..31] seeded with address-as-value (HR[5]=5 — easy mental map for diagnostics), HR[100] auto-incrementing via a 1Hz LinearGenerator binding (drives subscribe-and-receive integration tests so they have a register that actually changes without a write), HR[200..209] scratch range for write-roundtrip tests, coils 0..31 alternating on/off, coils 100..109 scratch. The Tick automation runs 0..65535 over 60s looping; bound to HR[100] via Binding_SINT16 — slow enough that a 250ms-poll integration test sees discrete jumps, fast enough that a 5s subscribe test sees several change notifications.
DL205.xmpp — AutomationDirect DirectLOGIC DL205/DL260 quirk simulator on port 502, slave id 1, modeling the behaviors documented in docs/v2/dl205.md as concrete register values so DL205 integration tests can assert each quirk WITHOUT a live PLC. Per-quirk encoding: V0 marker at HR[0]=0xCAFE proves register 0 is valid (rejects-register-0 rumour disproved); V2000 marker at HR[1024]=0x2000 proves V-memory octal-to-decimal mapping; V40400 marker at HR[8448]=0x4040 proves V40400→PDU 0x2100 (NOT register 0, contrary to the widespread shorthand); 'Hello' string at HR[1040..1042] packed first-char-low-byte (HR[1040]=0x6548 = 'H' lo + 'e' hi, HR[1041]=0x6C6C, HR[1042]=0x006F) — the headline string-byte-order quirk the user flagged; Float32 1.5f at HR[1056..1057] in CDAB word order (low word first: 0, then 0x3FC0); BCD register at HR[1072]=0x1234 representing decimal 1234 in BCD nibbles (NOT binary 0x04D2); 128-register block at HR[1280..1407] for FC03-128-cap testing; Y0 marker at coil 2048, C0 marker at coil 3072, scratch C-coils at 4000..4007 for write tests.
Critical limitation flagged inline + in README: ModbusPal 1.6b CANNOT represent the DL205 quirks semantically — it has no string binding, no BCD binding, no arbitrary-byte-layout binding (only SINT16/SINT32/FLOAT32 with word-order). So every DL205 quirk is encoded as a pre-computed raw 16-bit integer with the math worked out in inline comments above each register. Becomes unreadable past ~50 quirky registers; the README's 'alternatives' section recommends switching to pymodbus when that threshold approaches (pymodbus's ModbusSimulatorServer has first-class headless + scriptable callbacks for byte-level layouts).
Other ModbusPal 1.6b limitations called out in README: only holding_registers + coils sections in the official build (no input_registers / discrete_inputs — DL260 X-input markers can't be encoded faithfully here, FC02/FC04 tests wait for a fork or pymodbus); abandoned project (last release 1.6b, active forks at SCADA-LTS/ModbusPal, ControlThings-io/modbuspal, mrhenrike/ModbusPalEnhanced); no headless mode in the official JAR (-loadFile / -hide flags only in source-built forks); CVE-2018-10832 XXE on .xmpp import (don't import untrusted profiles — the in-repo ones are author-controlled).
README.md updated with: per-profile description tables, getting-started (download jar + java -jar + GUI File>Load>Run), MODBUS_SIM_ENDPOINT env-var override doc, two reference tables documenting which HR / coil address encodes which DL205 quirk + which test name asserts it (the same DL205_<behavior> naming convention from docs/v2/modbus-test-plan.md), 4-row alternatives comparison (pymodbus / diagslave / ModbusMechanic / ModRSsim2) for when ModbusPal can no longer carry the load, and a quick-reference XML format table at the bottom for future-me hand-authoring more profiles.
Pure documentation + test-asset PR — no code changes. The integration tests that consume these profiles (the actual DL205_<behavior> facts) land one at a time in PR 43+ as user validates each quirk via ModbusPal on the bench.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 20:05:20 -04:00
..
Phase 3 PR 28 — Admin UI cert-trust management page. New /certificates route (FleetAdmin-only) surfaces the OPC UA server's PKI store rejected + trusted certs and gives operators Trust / Delete / Revoke actions so rejected client certs can be promoted without touching disk. CertTrustService reads $PkiStoreRoot/{rejected,trusted}/certs/*.der files directly via X509CertificateLoader — no Opc.Ua dependency in the Admin project, which keeps the Admin host runnable on a machine that doesn't have the full Server install locally (only needs the shared PKI directory reachable; typical deployment has Admin + Server side-by-side on the same box and PkiStoreRoot defaults match so a plain-vanilla install needs no override). CertTrustOptions bound from the Admin's 'CertTrust:PkiStoreRoot' section, default %ProgramData%\OtOpcUa\pki (matches OpcUaServerOptions.PkiStoreRoot default). Trust action moves the .der from rejected/certs/ to trusted/certs/ via File.Move(overwrite:true) — idempotent, tolerates a concurrent operator doing the same move. Delete wipes the file. Revoke removes from trusted/certs/ (Opc.Ua re-reads the Directory store on each new client handshake, so no explicit reload signal is needed; operators retry the rejected connection after trusting). Thumbprint matching is case-insensitive because X509Certificate2.Thumbprint is upper-case hex but operators copy-paste from logs that sometimes lowercase it. Malformed files in the store are logged + skipped — a single bad .der can't take the whole management page offline. Missing store directories produce empty lists rather than exceptions so a pristine install (Server never run yet, no rejected/trusted dirs yet) doesn't crash the page.
2026-04-18 14:37:55 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 24 — Modbus PLC data type extensions. Extends ModbusDataType beyond the textbook Int16/UInt16/Int32/UInt32/Float32 set with Int64/UInt64/Float64 (4-register types), BitInRegister (single bit within a holding register, BitIndex 0-15 LSB-first), and String (ASCII packed 2 chars per register with StringLength-driven sizing). Adds ModbusByteOrder enum on ModbusTagDefinition covering the two word-orderings that matter in the real PLC population: BigEndian (ABCD — Modbus TCP standard, Schneider PLCs that follow it strictly) and WordSwap (CDAB — Siemens S7 family, several Allen-Bradley series, some Modicon families). NormalizeWordOrder helper reverses word pairs in-place for 32-bit values and reverses all four words for 64-bit values (keeps bytes big-endian within each register, which is universal; swaps only the word positions). Internal codec surface switched from (bytes, ModbusDataType) pairs to (bytes, ModbusTagDefinition) because the tag carries the ByteOrder + BitIndex + StringLength context the codec needs; RegisterCount similarly takes the tag so strings can compute ceil(StringLength/2). DriverDataType mapping in MapDataType extended to cover the new logical types — Int64/UInt64 widen to Int32 (PR 25 follow-up: extend DriverDataType enum with Int64 to avoid precision loss), Float64 maps to DriverDataType.Float64, String maps to DriverDataType.String, BitInRegister surfaces as Boolean, all other mappings preserved. BitInRegister writes throw a deliberate InvalidOperationException with a 'read-modify-write' hint — to atomically flip a single bit the driver needs to FC03 the register, OR/AND in the bit, then FC06 it back; that's a separate PR because the bit-modify atomicity story needs a per-register mutex and optional compare-and-write semantics. Everything else (decoder paths for both byte orders, Int64/UInt64/Float64 encode + decode, bit-index extraction across both register halves, String nul-truncation on decode, String nul-padding on encode) ships here. Tests (21 new ModbusDataTypeTests): RegisterCount_returns_correct_register_count_per_type theory (10 rows covering every numeric type); RegisterCount_for_String_rounds_up_to_register_pair theory (5 rows including the 0-char edge case that returns 0 registers); Int32_BigEndian_decodes_ABCD_layout + Int32_WordSwap_decodes_CDAB_layout + Float32_WordSwap_encode_decode_roundtrips (covers the two most-common 32-bit orderings); Int64_BigEndian_roundtrips + UInt64_WordSwap_reverses_four_words (word-swap on 64-bit reverses the four-word layout explicitly, with the test computing the expected wire shape by hand rather than trusting the implementation) + Float64_roundtrips_under_word_swap (3.14159265358979 survives the round-trip with 1e-12 tolerance); BitInRegister_extracts_bit_at_index theory (6 rows including LSB, MSB, and arbitrary bits in a multi-bit mask); BitInRegister_write_is_not_supported_in_PR24 (asserts the exception message steers the reader to the 'read-modify-write' follow-up); String_decodes_ASCII_packed_two_chars_per_register (decodes 'HELLO!' from 3 packed registers with the 'HELLO!'u8 test-only UTF-8 literal which happens to equal the ASCII bytes for this ASCII input); String_decode_truncates_at_first_nul ('Hi' padded with nuls reads back as 'Hi'); String_encode_nul_pads_remaining_bytes (short input writes remaining bytes as 0). Full solution: 0 errors, 217 unit + integration tests pass (22 + 30 new Modbus = 52 Modbus total, 165 pre-existing). ModbusDriver capability footprint now matches the most common industrial PLC workloads — Siemens S7 + Allen-Bradley + Modicon all supported via ByteOrder config without driver forks.
2026-04-18 12:27:12 -04:00