Joseph Doherty c36903d6a0 Auto: opcuaclient-12 — IHistoryProvider.ReadEventsAsync EventFilter spec + impl
Adds a filter-aware overload of IHistoryProvider.ReadEventsAsync that carries
EventFilter SelectClauses + WhereClause, and implements it on the OPC UA
Client driver via Session.HistoryReadAsync + ReadEventDetails.

The change is additive (default-impl returns NotSupportedException) so the
existing Galaxy.Proxy.GalaxyProxyDriver implementation keeps compiling
against the fixed-field overload — no cross-driver refactor required.

* Core.Abstractions: new EventHistoryRequest / SimpleAttributeSpec /
  ContentFilterSpec records mirror the OPC UA wire shape transport-neutrally.
  HistoricalEventBatch / HistoricalEventRow carry an open-ended Fields bag
  keyed by SimpleAttributeSpec.FieldName so server-side dispatch can re-align
  with the client's wire-side SelectClause order.
* OpcUaClient driver: new ReadEventsAsync(fullReference, EventHistoryRequest, ct)
  builds an EventFilter, calls Session.HistoryReadAsync, and unwraps
  HistoryEvent.Events into HistoricalEventBatch rows. Default SelectClause
  set matches BuildHistoryEvent on the server side. ContentFilter bytes are
  decoded through the live session's MessageContext (passthrough — the
  driver does not evaluate filters).
* Unit tests: 7 new tests cover SelectClause translation, default-clause
  fallback, malformed where-clause swallowing, uninitialized-driver guard,
  null-request guard, and IHistoryProvider default fallback.
* Integration scaffold: build-only [Fact] gated on opc-plc --alm; flips to
  green when the fixture image is upgraded.
* Docs: HistoryRead Events section in docs/drivers/OpcUaClient.md plus a
  cross-link from Client.CLI.md historyread page.
* E2E: -HistoryEvents switch on scripts/e2e/test-opcuaclient.ps1 confirms
  the gateway round-trips HistoryReadEvents without
  BadHistoryOperationUnsupported (gated; defaults to skip).

Closes #284
2026-04-26 09:29:40 -04:00
..

E2E CLI test scripts

End-to-end black-box tests that drive each protocol through its driver CLI and verify the resulting OPC UA address-space state through otopcua-cli. They answer one question per driver:

If I poke the real PLC through the driver, does the running OtOpcUa server see the change?

This is the acceptance gate v1 was missing — the driver-level integration tests (tests/.../IntegrationTests/) confirm the driver sees the PLC, and the OPC UA Client.CLI.Tests confirm the client sees the server — but nothing glued them end-to-end. These scripts close that loop.

Five-stage test per driver

Every per-driver script runs the same five tests. The goal is to prove both directions across the bridge plus subscription delivery — forward-only coverage would miss writable-flag drops, IWritable dispatch bugs, and broken data-change notification paths where a fresh read still returns the right value.

  1. probe — driver CLI opens a session + reads a sentinel. Confirms the simulator / PLC is reachable and speaking the protocol.
  2. Driver loopback — write a random value via the driver CLI, read it back via the same CLI. Confirms the driver round-trips without involving the OPC UA server. A failure here is a driver bug, not a server-bridge bug.
  3. Forward bridge (driver → server → client) — write a different random value via the driver CLI, wait --ServerPollDelaySec (default 3s), read the OPC UA NodeId the server publishes that tag at via otopcua-cli read. Confirms reads propagate from PLC to OPC UA client.
  4. Reverse bridge (client → server → driver) — write a fresh random value via otopcua-cli write against the same NodeId, wait --DriverPollDelaySec (default 3s), read the PLC-side via the driver CLI. Confirms writes propagate the other way — catches writable-flag drops, ACL misconfiguration, and IWritable dispatch bugs the forward test can't see.
  5. Subscribe-sees-change — start otopcua-cli subscribe --duration N in the background, give it --SettleSec (default 2s) to attach, write a random value via the driver CLI, wait for the subscription window to close, and assert the captured output mentions the new value. Confirms the server's monitored-item + data-change path actually fires — not just that a fresh read returns the new value.

The OtOpcUa server must already be running with a config that (a) binds a driver instance to the same PLC the script points at, and (b) publishes the address the script writes under a NodeId the script knows. Those NodeIds live in e2e-config.json (see below). The published tag must be writable — stages 4 + 5 will fail against a read-only tag.

Status

Stages 1 + 2 (driver-side probe + loopback) are verified end-to-end against the pymodbus / ab_server / python-snap7 fixtures. Stages 3-5 (anything crossing the OtOpcUa server) are blocked on server-side driver factory wiring:

  • src/ZB.MOM.WW.OtOpcUa.Server/Program.cs only registers Galaxy + FOCAS factories. DriverInstanceBootstrapper skips any DriverType without a registered factory — so Modbus / AB CIP / AB Legacy / S7 / TwinCAT rows in the Config DB are silently no-op'd even when the seed is perfect.
  • No Config DB seed script exists for non-Galaxy drivers; Admin UI is currently the only path to author one.

Tracking: #209 (umbrella) → #210 (Modbus), #211 (AB CIP), #212 (S7), #213 (AB Legacy, also hardware-gated — #222). Each child issue lists the factory class to write + the seed SQL shape + the verification command.

Until those ship, stages 3-5 will fail with "read failed" (nothing published at that NodeId) and [FAIL] the suite even on a running server.

Prereqs

  1. OtOpcUa server running on opc.tcp://localhost:4840 (or pass -OpcUaUrl to override). The server's Config DB must define a driver instance per protocol you want to test, bound to the matching simulator endpoint.
  2. Per-driver simulators running. See docs/v2/test-data-sources.md for the simulator matrix — pymodbus / ab_server / python-snap7 / opc-plc cover Modbus / AB / S7 / OPC UA Client. FOCAS and TwinCAT have no public simulator; they are gated with env-var skip flags below.
  3. PowerShell 7+. The runner uses null-coalescing + Set-StrictMode; the Windows-PowerShell-5.1 shell will not parse test-all.ps1.
  4. .NET 10 SDK. Each script either runs dotnet run --project src/ZB.MOM.WW.OtOpcUa.Driver.<Name>.Cli directly, or if $env:OTOPCUA_CLI_BIN points at a publish folder, runs the pre-built otopcua-*.exe from there (faster for repeat loops).

Running

One protocol at a time

./scripts/e2e/test-modbus.ps1 `
  -ModbusHost    127.0.0.1:5502 `
  -BridgeNodeId "ns=2;s=Modbus/HR100"

Every per-protocol script takes the driver endpoint, the address to write, and the OPC UA NodeId the server exposes it at.

Full matrix

./scripts/e2e/test-all.ps1 `
  -ConfigFile ./scripts/e2e/e2e-config.json

The runner reads the sidecar JSON, invokes each driver's script with the parameters from that section, and prints a FINAL MATRIX showing PASS / FAIL / SKIP per driver. Any driver absent from the sidecar is SKIP-ed rather than failing hard — useful on dev boxes that only have one simulator up.

Sidecar format

Copy e2e-config.sample.jsone2e-config.json and fill in the NodeIds from your server's Config DB. The file is .gitignore-d (each dev's NodeIds are specific to their local seed). Omit a driver section to skip it.

Expected pass/fail matrix (default config)

Driver Gate Default state on a clean dev box
Modbus PASS (pymodbus fixture)
AB CIP PASS (ab_server fixture)
AB Legacy PASS (ab_server SLC500/MicroLogix/PLC-5 profiles; /1,0 cip-path required for the Docker fixture)
Galaxy PASS (requires OtOpcUaGalaxyHost + a live Galaxy; 7 stages including alarms + history)
S7 PASS (python-snap7 fixture)
FOCAS FOCAS_TRUST_WIRE=1 SKIP (no public simulator — task #222 lab rig)
TwinCAT TWINCAT_TRUST_WIRE=1 SKIP (needs XAR or standalone Router — task #221)
Phase 7 PASS if the Modbus instance seeds a VT_DoubledHR100 virtual tag + AlarmHigh scripted alarm

Set the *_TRUST_WIRE env vars to 1 when you've pointed the script at real hardware or a properly-configured simulator.

Output

Each step prints one of:

  • [PASS] ... — step succeeded
  • [FAIL] ... — step failed, stdout of the failing CLI is echoed below for diagnosis
  • [SKIP] ... — step short-circuited (env-var gate)
  • [INFO] ... — progress note (e.g., "waiting 3s for server-side poll")

The runner ends with a coloured summary per driver:

==================== FINAL MATRIX ====================
  modbus     PASS
  abcip      PASS
  ablegacy   SKIP (no config entry)
  s7         PASS
  focas      SKIP (no config entry)
  twincat    SKIP (no config entry)
  phase7     PASS
All present suites passed.

Non-zero exit if any present suite failed. SKIPs do not fail the run.

Why this is separate from dotnet test

dotnet test covers driver-layer + server-layer correctness in isolation — mocks + in-process test hosts. These e2e scripts cover the integration seam that unit tests can't cover by design: a live OPC UA server process, a live simulator, and the wire between them. Run them before a v2 release-readiness sign-off, after a driver-layer change that could plausibly affect the NodeManager contract, and before any "it works on my box" handoff to QA.