Files
lmxopcua/tests/Server/ZB.MOM.WW.OtOpcUa.AdminUI.Tests/Uns/ModbusDeviceModelTests.cs
T
Joseph Doherty 844f93f64f feat(adminui): B2-WP3 driver/device config modals + page-to-form refactor
Extract the 8 typed driver pages into embeddable <Driver>DriverForm bodies
(channel/protocol config) and add per-driver <Driver>DeviceForm bodies
(connection endpoint -> Device.DeviceConfig, v3 endpoint split). New
DriverConfigModal + DeviceModal dispatch by DriverType (DriverTypeNames) for
the /raw tree; Test-connect inside DeviceModal builds the merged Driver+Device
config transiently via DriverDeviceConfigMerger. Routed pages now host the
form bodies and keep working. Round-trip + enum-serialization guard tests for
the Modbus driver form + Modbus device model; retargeted the existing
page-form serialization tests + the _jsonOpts converter guard to the forms.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 03:26:24 -04:00

71 lines
2.2 KiB
C#

using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.AdminUI.Components.Shared.Drivers.DeviceForms;
namespace ZB.MOM.WW.OtOpcUa.AdminUI.Tests.Uns;
/// <summary>
/// Round-trip guard for the Modbus <b>device</b> endpoint model — the gate-critical DeviceConfig
/// surface. Endpoint keys MUST be PascalCase (Host/Port/UnitId) so the merged probe config binds via
/// the runtime's case-insensitive deserializer, matching the seed and Wave-B service tests.
/// </summary>
public sealed class ModbusDeviceModelTests
{
[Theory]
[InlineData(null)]
[InlineData("")]
[InlineData(" ")]
[InlineData("{}")]
public void FromJson_returns_defaults_for_empty_input(string? json)
{
var m = ModbusDeviceModel.FromJson(json);
m.Host.ShouldBe("127.0.0.1");
m.Port.ShouldBe(502);
m.UnitId.ShouldBe(1);
}
[Fact]
public void Round_trip_preserves_endpoint_fields()
{
var m = new ModbusDeviceModel { Host = "10.100.0.35", Port = 5020, UnitId = 7 };
var json = m.ToJson();
var m2 = ModbusDeviceModel.FromJson(json);
m2.Host.ShouldBe("10.100.0.35");
m2.Port.ShouldBe(5020);
m2.UnitId.ShouldBe(7);
}
[Fact]
public void ToJson_emits_PascalCase_endpoint_keys()
{
var json = new ModbusDeviceModel { Host = "10.1.2.3", Port = 5020, UnitId = 1 }.ToJson();
// Runtime binds ModbusDriverOptions.Host/Port/UnitId from these exact PascalCase keys.
json.ShouldContain("\"Host\":\"10.1.2.3\"");
json.ShouldContain("\"Port\":5020");
json.ShouldContain("\"UnitId\":1");
}
[Fact]
public void FromJson_then_ToJson_preserves_unknown_keys()
{
var json = ModbusDeviceModel
.FromJson("""{"Host":"10.1.2.3","Port":5020,"UnitId":1,"customKey":"keepme"}""")
.ToJson();
json.ShouldContain("customKey");
json.ShouldContain("keepme");
json.ShouldContain("\"Host\":\"10.1.2.3\"");
}
[Fact]
public void Validate_flags_blank_host()
{
new ModbusDeviceModel { Host = "" }.Validate().ShouldNotBeNull();