Files
lmxopcua/src/ZB.MOM.WW.OtOpcUa.Core/OpcUa
Joseph Doherty c1cab33e38 Phase 6.4 Stream D server-side — IdentificationFolderBuilder materializes OPC 40010 Machinery Identification sub-folder
Closes the server-side / non-UI piece of Phase 6.4 Stream D. The Razor
`IdentificationFields.razor` component for Admin-UI editing ships separately
when the Admin UI pass lands (still tracked under #157 UI follow-up).

Core.OpcUa additions:
- IdentificationFolderBuilder — pure-function builder that materializes the
  OPC 40010 Machinery companion-spec Identification sub-folder per decision
  #139. Reads the nine nullable columns off an Equipment row:
  Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision,
  YearOfConstruction (short → OPC UA Int32), AssetLocation, ManufacturerUri,
  DeviceManualUri. Emits one AddProperty call per non-null field; skips the
  sub-folder entirely when all nine are null so browse trees don't carry
  pointless empty folders.
- HasAnyFields(equipment) — cheap short-circuit so callers can decide
  whether to invoke Folder() at all.
- FolderName constant ("Identification") + FieldNames list exposed so
  downstream tools / tests can cross-reference without duplicating the
  decision-#139 field set.

ACL binding: the sub-folder + variables live under the Equipment node so
Phase 6.2's PermissionTrie treats them as part of the Equipment ScopeId —
no new scope level. A user with Equipment-level grant reads the
Identification fields; a user without gets BadUserAccessDenied on both the
Equipment node + its Identification variables. Documented in the class
remarks; cross-reference update to acl-design.md is a follow-up.

Tests (9 new IdentificationFolderBuilderTests):
- HasAnyFields all-null false / any-non-null true.
- Build all-null returns null + doesn't emit Folder.
- Build fully-populated emits all 9 fields in decision #139 order.
- Only non-null fields are emitted (3-of-9 case).
- YearOfConstruction short widens to DriverDataType.Int32 with int value.
- String values round-trip through AddProperty.
- FieldNames constant matches decision #139 exactly.
- FolderName is "Identification".

Full solution dotnet test: 1202 passing (was 1193, +9). Pre-existing
Client.CLI Subscribe flake unchanged.

Production integration: the component that consumes this is the
address-space-build flow that walks the live Equipment table + calls
IdentificationFolderBuilder.Build(equipmentFolder, equipment) under each
Equipment node. That integration is the remaining Stream D follow-up
alongside the Razor UI component.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-19 11:57:39 -04:00
..
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00