Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/DL205/DL205CoilMappingTests.cs
T
Joseph Doherty a4c61989b2 test(v3): migrate 6 driver IntegrationTests to RawTags API
Replace pre-declared options.Tags (typed <Driver>TagDefinition lists) with
options.RawTags (IReadOnlyList<RawTagEntry>) across all 6 Docker-gated driver
integration suites so they COMPILE against the v3 driver API.

Each project gets a local <Driver>RawTags helper mirroring the unit-test
project's helper: it serialises a typed def back to its TagConfig blob via the
driver's <Driver>TagDefinitionFactory.ToTagConfig and packages it as a
RawTagEntry (RawPath = def.Name; DeviceName = def.DeviceHostAddress for the
multi-device drivers AbCip/AbLegacy/TwinCAT/FOCAS). Test intent (addresses,
data types, device routing, assertions) is unchanged — only the
tag-authoring/config-delivery shape was migrated.

Docker-gated: these still skip at runtime without fixtures; COMPILE is the gate.
2026-07-15 20:59:42 -04:00

113 lines
4.8 KiB
C#

using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
/// <summary>
/// Verifies DL260 I/O-memory coil mappings against the <c>dl205.json</c> pymodbus profile.
/// DirectLOGIC Y-outputs and C-relays are exposed to Modbus as FC01/FC05 coils, but at
/// non-zero base addresses that confuse operators used to "Y0 is the first coil". The sim
/// seeds Y0 → coil 2048 = ON and C0 → coil 3072 = ON as fixed markers.
/// </summary>
[Collection(ModbusSimulatorCollection.Name)]
[Trait("Category", "Integration")]
[Trait("Device", "DL205")]
public sealed class DL205CoilMappingTests(ModbusSimulatorFixture sim)
{
/// <summary>Verifies that DirectLOGIC Y0 output maps to Modbus coil 2048.</summary>
[Fact]
public async Task DL260_Y0_maps_to_coil_2048()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
StringComparison.OrdinalIgnoreCase))
{
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
}
var coil = DirectLogicAddress.YOutputToCoil("Y0");
coil.ShouldBe((ushort)2048);
var options = BuildOptions(sim, [
new ModbusTagDefinition("DL260_Y0",
ModbusRegion.Coils, Address: coil,
DataType: ModbusDataType.Bool, Writable: false),
]);
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-y0");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["DL260_Y0"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
results[0].Value.ShouldBe(true, "dl205.json seeds coil 2048 (Y0) = ON");
}
/// <summary>Verifies that DirectLOGIC C0 relay maps to Modbus coil 3072.</summary>
[Fact]
public async Task DL260_C0_maps_to_coil_3072()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
StringComparison.OrdinalIgnoreCase))
{
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
}
var coil = DirectLogicAddress.CRelayToCoil("C0");
coil.ShouldBe((ushort)3072);
var options = BuildOptions(sim, [
new ModbusTagDefinition("DL260_C0",
ModbusRegion.Coils, Address: coil,
DataType: ModbusDataType.Bool, Writable: false),
]);
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-c0");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var results = await driver.ReadAsync(["DL260_C0"], TestContext.Current.CancellationToken);
results[0].StatusCode.ShouldBe(0u);
results[0].Value.ShouldBe(true, "dl205.json seeds coil 3072 (C0) = ON");
}
/// <summary>Verifies that a scratch DirectLOGIC C relay supports write and read operations.</summary>
[Fact]
public async Task DL260_scratch_Crelay_supports_write_then_read()
{
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
StringComparison.OrdinalIgnoreCase))
{
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
}
// Scratch C-relay at coil 4000 (per dl205.json _quirk note) is writable. Write=true then
// read back to confirm FC05 round-trip works against the DL-mapped coil bank.
var options = BuildOptions(sim, [
new ModbusTagDefinition("DL260_C_Scratch",
ModbusRegion.Coils, Address: 4000,
DataType: ModbusDataType.Bool, Writable: true),
]);
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-cscratch");
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
var writeResults = await driver.WriteAsync(
[new(FullReference: "DL260_C_Scratch", Value: true)],
TestContext.Current.CancellationToken);
writeResults[0].StatusCode.ShouldBe(0u);
var readResults = await driver.ReadAsync(["DL260_C_Scratch"], TestContext.Current.CancellationToken);
readResults[0].StatusCode.ShouldBe(0u);
readResults[0].Value.ShouldBe(true);
}
private static ModbusDriverOptions BuildOptions(ModbusSimulatorFixture sim, IReadOnlyList<ModbusTagDefinition> tags)
=> new()
{
Host = sim.Host,
Port = sim.Port,
UnitId = 1,
Timeout = TimeSpan.FromSeconds(2),
RawTags = ModbusRawTags.Entries(tags),
Probe = new ModbusProbeOptions { Enabled = false },
};
}