Joseph Doherty 8be82e02c2 Path-based NodeIds — decouple client contract from driver address
The pre-refactor design minted OPC UA NodeIds directly from the driver's
FullReference (the native-address string). That had three long-term
problems:

1. OPC UA Part 3 §5.2.2 requires NodeIds to be immutable across a node's
   lifetime. A rename of the underlying device address — Galaxy attribute,
   S7 tag, Modbus register alias — changed the NodeId and broke every
   client that had pinned the previous identifier.
2. Two drivers with coincidentally-matching native addresses (e.g. `temp`
   in Modbus and `temp` in S7 under different Equipment rows) collided on
   the NodeId identifier.
3. TagConfig was being placed verbatim on the wire; for drivers whose
   TagConfig is JSON (every driver shipped today, per the
   CK_Tag_TagConfig_IsJson check constraint), clients saw the raw JSON
   blob as the NodeId string.

Refactor:

* DriverNodeManager.Variable now mints a stable path-based NodeId
  `{driverId}/{folder-path}/{browseName}` and records the driver-side
  FullReference in a new _fullRefByNodeId map. OnReadValue / OnWriteValue
  / ResolveFullRef look the FullReference up via that map instead of
  casting NodeId.Identifier. The old cast path is preserved as a
  fallback so any test fixture that still registers variables with
  FullRef-shaped NodeIds keeps working.

* EquipmentNodeWalker.AddTagVariable now extracts the cross-driver
  `FullName` field from Tag.TagConfig before handing the address to
  DriverAttributeInfo. Every shipped driver stores the wire reference in
  TagConfig[FullName]; falling back to the raw string covers any future
  driver that wants an opaque non-JSON address. ExtractFullName is
  exposed internal for unit coverage.

* scripts/e2e/test-galaxy.ps1 defaults updated to the new path-based
  NodeIds. Verified live against p7-smoke-galaxy on the dev box:
  `ns=2;s=p7-smoke-galaxy/lab-floor/galaxy-line/reactor-1/Source` reads
  return Status=0x00000000 with a real Galaxy byte-array value.

Test suite: 195/195 Core.Tests + 283/283 Server.Tests green. Five new
ExtractFullName / FullName-passthrough tests added.

Task #112 GA-3 — golden-path read verified end-to-end; remaining E2E
script stages still blocked on pre-existing issues (ScriptedAlarm
predicate NRE on empty upstream cache, PowerShell $changeLines.Count
guard), tracked separately.
Task #134 — complete.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-24 16:57:20 -04:00
..
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00