Joseph Doherty b8df230eb8 Task #152 — Modbus coalescing: surface auto-prohibitions through diagnostics
Auto-prohibited ranges (#148) were previously visible only through an
internal AutoProhibitedRangeCount accessor used by tests. Production
operators had no way to see what the planner had learned without pulling
logs or inspecting driver state.

Changes:

- New public record `ModbusAutoProhibition(UnitId, Region, StartAddress,
  EndAddress, LastProbedUtc, BisectionPending)` — operator-facing snapshot
  shape. Lives in the addressing assembly's logical namespace alongside
  the other public types.
- `ModbusDriver.GetAutoProhibitedRanges()` returns
  `IReadOnlyList<ModbusAutoProhibition>` — a copy of the live prohibition
  map. Lock-protected snapshot so consumers don't race with the re-probe
  loop.
- RecordAutoProhibition tracks first-fire vs re-fire via the dictionary
  insert path, leaving a hook to add structured logging once an ILogger
  is plumbed through (currently elided to keep the constructor minimal
  for testability — a future change can wire ILogger and emit a single
  warning per first-fire).

Tests (1 new, additive to the 6 in ModbusCoalescingAutoRecoveryTests):
- GetAutoProhibitedRanges_Surfaces_Operator_Visible_Snapshot — confirms
  the snapshot shape: empty before any failure, populated with correct
  UnitId/Region/Start/End/BisectionPending after a failed coalesced read,
  LastProbedUtc within the recent past.

Docs:
- docs/v2/modbus-addressing.md — new "Coalescing auto-recovery" subsection
  consolidates the #148/#150/#151/#152 surface in one place. Documents
  the diagnostic accessor + flags the in-process consumption pattern
  (Server health endpoints today; Admin UI when an RPC channel exists).

239 + 1 = 240 unit tests green.

Caveat: the Admin UI surfacing (table render, "clear all prohibitions"
button) is intentionally NOT shipped here. Admin can't reach a live
ModbusDriver instance without a driver-diagnostics RPC channel that
doesn't exist yet — that's a larger architectural piece. For now the
data is queryable in-process by the Server's health endpoints; once an
RPC channel lands, Admin can wire the existing GetAutoProhibitedRanges
into a Blazor table without further driver changes.
2026-04-25 01:19:10 -04:00
..
Client rename residuals: lmxopcua-cli → otopcua-cli + LmxOpcUaClient → OtOpcUaClient with migration shim. Closes task #208 (the executable-name + LocalAppData-folder slice that was called out in Client.CLI.md / Client.UI.md as a deliberately-deferred residual of the Phase 0 rename). Six source references flipped to the canonical OtOpcUaClient spelling: Program.cs CliFx executable name + description (lmxopcua-cli → otopcua-cli), DefaultApplicationConfigurationFactory.cs ApplicationName + ApplicationUri (LmxOpcUaClient + urn:localhost:LmxOpcUaClient → OtOpcUaClient + urn:localhost:OtOpcUaClient), OpcUaClientService.CreateSessionAsync session-name arg, ConnectionSettings.CertificateStorePath default, MainWindowViewModel.CertificateStorePath default, JsonSettingsService.SettingsDir. Two consuming tests (ConnectionSettingsTests + MainWindowViewModelTests) updated to assert the new canonical name. New ClientStoragePaths static helper at src/ZB.MOM.WW.OtOpcUa.Client.Shared/ClientStoragePaths.cs is the migration shim — single entry point for the PKI root + pki subpath, runs a one-shot legacy-folder probe on first resolution: if {LocalAppData}/LmxOpcUaClient/ exists + {LocalAppData}/OtOpcUaClient/ does not, Directory.Move renames it in place (atomic on NTFS within the same volume) so trusted server certs + saved connection settings persist across the rename without operator action. Idempotent per-process via a Lock-guarded _migrationChecked flag so repeated CertificateStorePath getter calls on the hot path pay no IO cost beyond the first. Fresh-install path (neither folder exists) + already-migrated path (only canonical exists) + manual-override path (both exist — developer has set up something explicit) are all no-ops that leave state alone. IOException on the Directory.Move is swallowed + logged as a false return so a concurrent peer process losing the race doesn't crash the consumer; the losing process falls back to whatever state exists. Five new ClientStoragePathsTests assert: GetRoot ends with canonical name under LocalAppData, GetPkiPath nests pki under root, CanonicalFolderName is OtOpcUaClient, LegacyFolderName is LmxOpcUaClient (the migration contract — a typo here would leak the legacy folder past the shim), repeat invocation returns false after first-touch arms the in-process guard. Doc-side residual-explanation notes in docs/Client.CLI.md + docs/Client.UI.md are dropped now that the rename is real; replaced with a short "pre-#208 dev boxes migrate automatically on first launch" note that points at ClientStoragePaths. Sample CLI invocations in Client.CLI.md updated via sed from lmxopcua-cli to otopcua-cli across every command block (14 replacements). Pre-existing staleness in SubscribeCommandTests.Execute_PrintsSubscriptionMessage surfaced during the test run — the CLI's subscribe command has long since switched to an aggregate "Subscribed to {count}/{total} nodes (interval: ...)" output format but the test still asserted the original single-node form. Updated the assertion to match current output + added a comment explaining the change; this is unrelated to the rename but was blocking a green Client.CLI.Tests run. Full solution build 0 errors; Client.Shared.Tests 136/136 + 5 new shim tests passing; Client.UI.Tests 98/98; Client.CLI.Tests 52/52 (was 51/52 before the subscribe-test fix). No Admin/Core/Server changes — this touches only the client layer.
2026-04-20 01:50:40 -04:00
Client rename residuals: lmxopcua-cli → otopcua-cli + LmxOpcUaClient → OtOpcUaClient with migration shim. Closes task #208 (the executable-name + LocalAppData-folder slice that was called out in Client.CLI.md / Client.UI.md as a deliberately-deferred residual of the Phase 0 rename). Six source references flipped to the canonical OtOpcUaClient spelling: Program.cs CliFx executable name + description (lmxopcua-cli → otopcua-cli), DefaultApplicationConfigurationFactory.cs ApplicationName + ApplicationUri (LmxOpcUaClient + urn:localhost:LmxOpcUaClient → OtOpcUaClient + urn:localhost:OtOpcUaClient), OpcUaClientService.CreateSessionAsync session-name arg, ConnectionSettings.CertificateStorePath default, MainWindowViewModel.CertificateStorePath default, JsonSettingsService.SettingsDir. Two consuming tests (ConnectionSettingsTests + MainWindowViewModelTests) updated to assert the new canonical name. New ClientStoragePaths static helper at src/ZB.MOM.WW.OtOpcUa.Client.Shared/ClientStoragePaths.cs is the migration shim — single entry point for the PKI root + pki subpath, runs a one-shot legacy-folder probe on first resolution: if {LocalAppData}/LmxOpcUaClient/ exists + {LocalAppData}/OtOpcUaClient/ does not, Directory.Move renames it in place (atomic on NTFS within the same volume) so trusted server certs + saved connection settings persist across the rename without operator action. Idempotent per-process via a Lock-guarded _migrationChecked flag so repeated CertificateStorePath getter calls on the hot path pay no IO cost beyond the first. Fresh-install path (neither folder exists) + already-migrated path (only canonical exists) + manual-override path (both exist — developer has set up something explicit) are all no-ops that leave state alone. IOException on the Directory.Move is swallowed + logged as a false return so a concurrent peer process losing the race doesn't crash the consumer; the losing process falls back to whatever state exists. Five new ClientStoragePathsTests assert: GetRoot ends with canonical name under LocalAppData, GetPkiPath nests pki under root, CanonicalFolderName is OtOpcUaClient, LegacyFolderName is LmxOpcUaClient (the migration contract — a typo here would leak the legacy folder past the shim), repeat invocation returns false after first-touch arms the in-process guard. Doc-side residual-explanation notes in docs/Client.CLI.md + docs/Client.UI.md are dropped now that the rename is real; replaced with a short "pre-#208 dev boxes migrate automatically on first launch" note that points at ClientStoragePaths. Sample CLI invocations in Client.CLI.md updated via sed from lmxopcua-cli to otopcua-cli across every command block (14 replacements). Pre-existing staleness in SubscribeCommandTests.Execute_PrintsSubscriptionMessage surfaced during the test run — the CLI's subscribe command has long since switched to an aggregate "Subscribed to {count}/{total} nodes (interval: ...)" output format but the test still asserted the original single-node form. Updated the assertion to match current output + added a comment explaining the change; this is unrelated to the rename but was blocking a green Client.CLI.Tests run. Full solution build 0 errors; Client.Shared.Tests 136/136 + 5 new shim tests passing; Client.UI.Tests 98/98; Client.CLI.Tests 52/52 (was 51/52 before the subscribe-test fix). No Admin/Core/Server changes — this touches only the client layer.
2026-04-20 01:50:40 -04:00

OtOpcUa documentation

Two tiers of documentation live here:

  • Current reference at the top level (docs/*.md) — describes what's shipped today. Start here for operator + integrator reference.
  • Implementation history + design notes at docs/v2/*.md — the authoritative plan + decision log the current reference is built from. Start here when you need the why behind an architectural choice, or when a top-level doc says "see plan.md § X".

The project was originally called LmxOpcUa (a single-driver Galaxy/MXAccess OPC UA server) and has since become OtOpcUa, a multi-driver OPC UA server platform. Any lingering LmxOpcUa-string in a path you see in docs is a deliberate residual (executable name lmxopcua-cli, client PKI folder {LocalAppData}/LmxOpcUaClient/) — fixing those requires migration shims + is tracked as follow-ups.

Platform overview

  • Core owns the OPC UA stack, address space, session/security/subscription machinery.
  • Drivers plug in via capability interfaces in ZB.MOM.WW.OtOpcUa.Core.Abstractions: IDriver, IReadable, IWritable, ITagDiscovery, ISubscribable, IHostConnectivityProbe, IAlarmSource, IHistoryProvider, IPerCallHostResolver. Each driver opts into whichever it supports.
  • Server is the OPC UA endpoint process (net10, x64). Hosts every driver except Galaxy in-process; talks to Galaxy via a named pipe because MXAccess COM is 32-bit-only.
  • Admin is the Blazor Server operator UI (net10, x64). Owns the Config DB draft/publish flow, ACL + role-grant authoring, fleet status + /metrics scrape endpoint.
  • Galaxy.Host is a .NET Framework 4.8 x86 Windows service that wraps MXAccess COM on an STA thread for the Galaxy driver.

Where to find what

Architecture + data-path reference

Doc Covers
OpcUaServer.md Top-level server architecture — Core, driver dispatch, Config DB, generations
AddressSpace.md GenericDriverNodeManager + ITagDiscovery + IAddressSpaceBuilder
ReadWriteOperations.md OPC UA Read/Write → CapabilityInvokerIReadable/IWritable
Subscriptions.md Monitored items → ISubscribable + per-driver subscription refcount
AlarmTracking.md IAlarmSource + AlarmSurfaceInvoker + OPC UA alarm conditions
DataTypeMapping.md Per-driver DriverAttributeInfo → OPC UA variable types
IncrementalSync.md Address-space rebuild on redeploy + sp_ComputeGenerationDiff
HistoricalDataAccess.md IHistoryProvider as a per-driver optional capability
VirtualTags.md Core.Scripting + Core.VirtualTags — Roslyn script sandbox, engine, dispatch alongside driver tags
ScriptedAlarms.md Core.ScriptedAlarms — script-predicate IAlarmSource + Part 9 state machine

Two Core subsystems are shipped without a dedicated top-level doc; see the section in the linked doc:

Project See
Core.AlarmHistorian AlarmTracking.md § Alarm historian sink
Analyzers (Roslyn OTOPCUA0001) security.md § OTOPCUA0001 Analyzer

Drivers

Doc Covers
drivers/README.md Index of the eight shipped drivers + capability matrix
drivers/Galaxy.md Galaxy driver — MXAccess bridge, Host/Proxy split, named-pipe IPC
drivers/Galaxy-Repository.md Galaxy-specific discovery via the ZB SQL database

For Modbus / S7 / AB CIP / AB Legacy / TwinCAT / FOCAS / OPC UA Client specifics, see v2/driver-specs.md.

Operational

Doc Covers
Configuration.md appsettings bootstrap + Config DB + Admin UI draft/publish
security.md Transport security profiles, LDAP auth, ACL trie, role grants, OTOPCUA0001 analyzer
Redundancy.md RedundancyCoordinator, ServiceLevelCalculator, apply-lease, Prometheus metrics
ServiceHosting.md Three-process deploy (Server + Admin + Galaxy.Host) install/uninstall
StatusDashboard.md Pointer — superseded by v2/admin-ui.md

Client tooling

Doc Covers
Client.CLI.md otopcua-cli — OPC UA command-line client
Client.UI.md Avalonia desktop client
DriverClis.md Driver test-client CLIs — index + shared commands
Driver.Modbus.Cli.md otopcua-modbus-cli — Modbus-TCP
Driver.AbCip.Cli.md otopcua-abcip-cli — ControlLogix / CompactLogix / Micro800 / GuardLogix
Driver.AbLegacy.Cli.md otopcua-ablegacy-cli — SLC / MicroLogix / PLC-5 (PCCC)
Driver.S7.Cli.md otopcua-s7-cli — Siemens S7-300 / S7-400 / S7-1200 / S7-1500
Driver.TwinCAT.Cli.md otopcua-twincat-cli — Beckhoff TwinCAT 2/3 ADS
Driver.FOCAS.Cli.md otopcua-focas-cli — Fanuc FOCAS/2 CNC

Requirements

Doc Covers
reqs/HighLevelReqs.md HLRs — numbered system-level requirements
reqs/OpcUaServerReqs.md OPC UA server-layer reqs
reqs/ServiceHostReqs.md Per-process hosting reqs
reqs/ClientRequirements.md Client CLI + UI reqs
reqs/GalaxyRepositoryReqs.md Galaxy-scoped repository reqs
reqs/MxAccessClientReqs.md Galaxy-scoped MXAccess reqs
reqs/StatusDashboardReqs.md Pointer — superseded by Admin UI

Implementation history (docs/v2/)

Design decisions + phase plans + execution notes. Load-bearing cross-references from the top-level docs: