Joseph Doherty b5464f11ee Phase 3 PR 50 -- DL260 bit-memory address helpers (Y/C/X/SP) + live coil integration tests. Adds four new static helpers to DirectLogicAddress covering every discrete-memory bank on the DL260: YOutputToCoil (Y0=coil 2048), CRelayToCoil (C0=coil 3072), XInputToDiscrete (X0=DI 0), SpecialToDiscrete (SP0=DI 1024). Each helper takes the DirectLOGIC ladder-logic address (e.g. 'Y0', 'Y17', 'C1777') and adds the octal-decoded offset to the bank's Modbus base per the DL260 user manual's I/O-configuration chapter table. Uses the same 'octal-walk + reject 8/9' pattern as UserVMemoryToPdu so misaligned addresses fail loudly with a clear ArgumentException rather than silently hitting the wrong coil. Fixes a pymodbus-config bug surfaced during integration-test validation: dl205.json had bits entries at cell indices 2048 / 3072 / 4000, but pymodbus's ModbusSimulatorContext.validate divides bit addresses by 16 before indexing into the shared cell array -- so Modbus coil 2048 reads cell 128, not cell 2048. The sim was returning Illegal Data Address (exception 02) for every bit read in the Y/C/scratch range. Moved bits entries to cells 128 (Y bank marker = 0b101 for Y0=ON, Y1=OFF, Y2=ON), 192 (C bank marker = 0b101 for C0/C1/C2), 250 (scratch cell covering coils 4000..4015). write list updated to the correct cell addresses. Unit tests: YOutputToCoil theory sweep (Y0->2048, Y1->2049, Y7->2055, Y10->2056 octal-to-decimal, Y17->2063, Y777->2559 top of DL260 Y range), CRelayToCoil theory (C0->3072 through C1777->4095), XInputToDiscrete theory, SpecialToDiscrete theory (with case-insensitive 'SP' prefix). Bit_address_rejects_non_octal_digits (Y8/C9/X18), Bit_address_rejects_empty, accepts_lowercase_prefix, accepts_bare_octal_without_prefix. 48/48 Modbus.Tests pass. Integration tests: DL205CoilMappingTests with three facts -- DL260_Y0_maps_to_coil_2048 (FC01 at Y0 returns ON), DL260_C0_maps_to_coil_3072 (FC01 at C0 returns ON), DL260_scratch_Crelay_supports_write_then_read (FC05 write + FC01 read round-trip at coil 4000 proves the DL-mapped coil bank is fully read/write capable end-to-end). 9/9 DL205 integration tests pass against the pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205. Caller opts into the helpers per tag the same way as PR 47's V-memory helper -- pass DirectLogicAddress.YOutputToCoil("Y0") as the ModbusTagDefinition Address; no driver-wide DL-family flag. PR 51 adds the X-input read-side integration test (there's nothing to write since X-inputs are FC02 discrete inputs, read-only); PR 52 exception-code translation; PR 53 transport reconnect-on-drop since DL260 doesn't send TCP keepalives.
2026-04-18 22:22:42 -04:00
..
Phase 3 PR 50 -- DL260 bit-memory address helpers (Y/C/X/SP) + live coil integration tests. Adds four new static helpers to DirectLogicAddress covering every discrete-memory bank on the DL260: YOutputToCoil (Y0=coil 2048), CRelayToCoil (C0=coil 3072), XInputToDiscrete (X0=DI 0), SpecialToDiscrete (SP0=DI 1024). Each helper takes the DirectLOGIC ladder-logic address (e.g. 'Y0', 'Y17', 'C1777') and adds the octal-decoded offset to the bank's Modbus base per the DL260 user manual's I/O-configuration chapter table. Uses the same 'octal-walk + reject 8/9' pattern as UserVMemoryToPdu so misaligned addresses fail loudly with a clear ArgumentException rather than silently hitting the wrong coil. Fixes a pymodbus-config bug surfaced during integration-test validation: dl205.json had bits entries at cell indices 2048 / 3072 / 4000, but pymodbus's ModbusSimulatorContext.validate divides bit addresses by 16 before indexing into the shared cell array -- so Modbus coil 2048 reads cell 128, not cell 2048. The sim was returning Illegal Data Address (exception 02) for every bit read in the Y/C/scratch range. Moved bits entries to cells 128 (Y bank marker = 0b101 for Y0=ON, Y1=OFF, Y2=ON), 192 (C bank marker = 0b101 for C0/C1/C2), 250 (scratch cell covering coils 4000..4015). write list updated to the correct cell addresses. Unit tests: YOutputToCoil theory sweep (Y0->2048, Y1->2049, Y7->2055, Y10->2056 octal-to-decimal, Y17->2063, Y777->2559 top of DL260 Y range), CRelayToCoil theory (C0->3072 through C1777->4095), XInputToDiscrete theory, SpecialToDiscrete theory (with case-insensitive 'SP' prefix). Bit_address_rejects_non_octal_digits (Y8/C9/X18), Bit_address_rejects_empty, accepts_lowercase_prefix, accepts_bare_octal_without_prefix. 48/48 Modbus.Tests pass. Integration tests: DL205CoilMappingTests with three facts -- DL260_Y0_maps_to_coil_2048 (FC01 at Y0 returns ON), DL260_C0_maps_to_coil_3072 (FC01 at C0 returns ON), DL260_scratch_Crelay_supports_write_then_read (FC05 write + FC01 read round-trip at coil 4000 proves the DL-mapped coil bank is fully read/write capable end-to-end). 9/9 DL205 integration tests pass against the pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205. Caller opts into the helpers per tag the same way as PR 47's V-memory helper -- pass DirectLogicAddress.YOutputToCoil("Y0") as the ModbusTagDefinition Address; no driver-wide DL-family flag. PR 51 adds the X-input read-side integration test (there's nothing to write since X-inputs are FC02 discrete inputs, read-only); PR 52 exception-code translation; PR 53 transport reconnect-on-drop since DL260 doesn't send TCP keepalives.
2026-04-18 22:22:42 -04:00
Phase 3 PR 49 -- Per-device FC03/FC16 register caps with auto-chunking. Adds MaxRegistersPerRead (default 125, spec max) + MaxRegistersPerWrite (default 123, spec max) to ModbusDriverOptions. Reads that exceed the cap automatically split into consecutive FC03 requests: the driver dispatches chunks of [cap] regs at incrementing addresses, copies each response into an assembled byte[] buffer, and hands the full payload to DecodeRegister. From the caller's view a 240-char string read against a cap-100 device is still one Read() call returning one string -- the chunking is invisible, the wire shows N requests of cap-sized quantity plus one tail chunk. Writes are NOT auto-chunked. Splitting an FC16 across two transactions would lose atomicity -- mid-split crash leaves half the value written, which is strictly worse than rejecting upfront. Instead, writes exceeding MaxRegistersPerWrite throw InvalidOperationException with a message naming the tag + cap + the caller's escape hatch (shorten StringLength or split into multiple tags). The driver catches the exception internally and surfaces it to IWritable as BadInternalError so the caller pattern stays symmetric with other failure modes. Per-family cap cheat-sheet (documented in xml-doc on the option): Modbus-TCP spec = 125 read / 123 write, AutomationDirect DL205/DL260 = 128 read / 100 write (128 exceeds spec byte-count capacity so in practice 125 is the working ceiling), Mitsubishi Q/FX3U = 64 / 64, Omron CJ/CS = 125 / 123. Not all PLCs reject over-cap requests cleanly -- some drop the connection silently -- so having the cap enforced client-side prevents the hard-to-diagnose 'driver just stopped' failure mode. Unit tests: Read_within_cap_issues_single_FC03_request (control: no unnecessary chunking), Read_above_cap_splits_into_two_FC03_requests (120 regs / cap 100 -> 100+20, asserts exact per-chunk (Address,Quantity) and end-to-end payload continuity starting with register[100] high byte = 'A'), Read_cap_honors_Mitsubishi_lower_cap_of_64 (100 regs / cap 64 -> 64+36), Write_exceeding_cap_throws_instead_of_splitting (110 regs / cap 100 -> status != 0 AND Fc16Requests.Count == 0 to prove nothing was sent), Write_within_cap_proceeds_normally (control: cap honored on short writes too). Tests use a new RecordingTransport that captures the (Address, Quantity) tuple of every FC03/FC16 request so the chunk layout is directly assertable -- the existing FakeTransport does not expose request history. 103/103 Modbus.Tests pass; 6/6 DL205 integration tests still pass against the live pymodbus dl205 profile with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:58:49 -04:00
Phase 3 PR 46 -- DL205 BCD decoder (binary-coded-decimal numeric encoding). Adds ModbusDataType.Bcd16 and Bcd32 to the driver. Bcd16 is 1 register wide, Bcd32 is 2 registers wide; Bcd32 respects ModbusByteOrder (BigEndian/WordSwap) the same way Int32 does so the CDAB-style families (including DL205/DL260 themselves) can be configured. DecodeRegister uses the new internal DecodeBcd helper: walks each nibble from MSB to LSB, multiplies the running result by 10, adds the nibble as a decimal digit. Explicitly rejects nibbles > 9 with InvalidDataException -- hardware sometimes produces garbage during write-in-progress transitions and silently returning wrong numeric values would quietly corrupt the caller's data. EncodeRegister's new EncodeBcd inverts the operation (mod/div by 10 nibble-by-nibble) with an up-front overflow check against 10^nibbles-1. Why this matters for DL205/DL260: AutomationDirect DirectLOGIC uses BCD as the default numeric encoding for timers, counters, and operator-display numerics (not binary). A plain Int16 read of register 0x1234 returns 4660; the BCD path returns 1234. The two differ enough that silently defaulting to Int16 would give wildly wrong HMI values -- the caller must opt in to Bcd16/Bcd32 per tag. Unit tests: DecodeBcd (theory: 0,1,9,10,1234,9999), DecodeBcd_rejects_nibbles_above_nine, EncodeBcd (theory), Bcd16_decodes_DL205_register_1234_as_decimal_1234 (control: same bytes as Int16 decode to 4660), Bcd16_encode_round_trips_with_decode, Bcd16_encode_rejects_out_of_range_values, Bcd32_decodes_8_digits_big_endian, Bcd32_word_swap_handles_CDAB_layout, Bcd32_encode_round_trips_with_decode, Bcd_RegisterCount_matches_underlying_width. 66/66 Modbus.Tests pass. Integration test: DL205BcdQuirkTests.DL205_BCD16_decodes_HR1072_as_decimal_1234 against dl205.json pymodbus profile (HR[1072]=0x1234). Asserts Bcd16 decode=1234 AND Int16 decode=0x1234 on the same wire bytes to prove the paths are distinct. 3/3 DL205 integration tests pass with MODBUS_SIM_PROFILE=dl205.
2026-04-18 21:46:25 -04:00
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
2026-04-18 11:55:21 -04:00
Phase 3 PR 23 — Modbus IHostConnectivityProbe. ModbusDriver now implements 6 of 8 capability interfaces (adds IHostConnectivityProbe alongside IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable from the earlier PRs). Background probe loop kicks off in InitializeAsync when ModbusProbeOptions.Enabled is true, sends a cheap FC03 read-1-register at ProbeAddress (default 0) every Interval (default 5s) with a per-tick Timeout (default 2s), and tracks the single Modbus endpoint's state in the HostState machine. Initial state = Unknown; first successful probe transitions to Running; any transport/timeout failure transitions to Stopped; recovery transitions back to Running. OnHostStatusChanged fires exactly on transitions (not on repeat successes — prevents event-spam on a healthy connection). HostName format is 'host:port' so the Admin UI can display the endpoint uniformly with Galaxy platforms/engines in the fleet status dashboard. GetHostStatuses returns a single-item list with the current state + last-change timestamp (Modbus driver talks to exactly one endpoint per instance — operators spin up multiple driver instances for multi-PLC deployments). ShutdownAsync cancels the probe CTS before tearing down the transport so the loop can't log a spurious Stopped after intentional shutdown (OperationCanceledException caught separately from the 'real' transport errors). ModbusDriverOptions extended with ModbusProbeOptions sub-record (Enabled default true, Interval 5s, Timeout 2s, ProbeAddress ushort for PLCs that have register-0 policies; most PLCs tolerate an FC03 at 0 but some industrial gateways lock it). Tests (7 new ModbusProbeTests): Initial_state_is_Unknown_before_first_probe_tick (probe disabled, state stays Unknown, HostName formatted); First_successful_probe_transitions_to_Running (enabled, waits for probe count + event queue, asserts Unknown → Running with correct OldState/NewState); Transport_failure_transitions_to_Stopped (flip fake.Reachable = false mid-run, wait for state diff); Recovery_transitions_Stopped_back_to_Running (up → down → up, asserts ≥ 3 transitions); Repeated_successful_probes_do_not_generate_duplicate_Running_events (several hundred ms of stable probes, count stays at 1); Disabled_probe_stays_Unknown_and_fires_no_events (safety guard when operator wants to disable probing); Shutdown_stops_the_probe_loop (probe count captured at shutdown, delay 400ms, assert ≤ 1 extra to tolerate the narrow race where an in-flight tick completes after shutdown — the contract is 'no new ticks scheduled' not 'instantaneous freeze'). FlappyTransport fake exposes a volatile Reachable flag so tests can toggle the PLC availability mid-run, + ProbeCount counter so tests can assert the loop actually issued requests. WaitForStateAsync helper polls GetHostStatuses up to a deadline; tolerates scheduler jitter on slow CI runners. Full solution: 0 errors, 202 unit + integration tests pass (22 Modbus + 180 pre-existing).
2026-04-18 12:12:00 -04:00
Phase 3 PR 22 — Modbus ISubscribable via polling overlay. Modbus has no push model at the wire protocol (unlike MXAccess's OnDataChange callback or OPC UA's own Subscription service), so the driver layers a per-subscription polling loop on top of the existing IReadable path: SubscribeAsync returns an opaque ModbusSubscriptionHandle, starts a background Task.Run that sleeps for the requested publishing interval (floored to 100ms so a misconfigured sub-10ms request doesn't hammer the PLC), reads every subscribed tag through the same FC01/03/04 path the one-shot ReadAsync uses, diffs the returned DataValueSnapshot against the last known value per tag, and raises OnDataChange exactly when (a) it's the first poll (initial-data push per OPC UA Part 4 convention) or (b) boxed value changed or (c) StatusCode changed — stable values don't generate event traffic after the initial push, matching the v1 MXAccess OnDataChange shape. SubscriptionState record holds the handle + tag list + interval + per-subscription CancellationTokenSource + ConcurrentDictionary<string,DataValueSnapshot> LastValues; UnsubscribeAsync removes the state from _subscriptions and cancels the CTS, stopping the polling loop cleanly. Multiple overlapping subscriptions each get their own polling Task so a slow PLC on one subscription can't stall the others. ShutdownAsync cancels every active subscription CTS before tearing down the transport so the driver doesn't leave orphaned polling tasks pumping requests against a disposed socket. Transient poll errors are swallowed inside the loop (the loop continues to the next tick) — the driver's health surface reflects the last-known Degraded state from the underlying ReadAsync path. OperationCanceledException is caught separately to exit the loop silently on unsubscribe/shutdown. Tests (6 new ModbusSubscriptionTests): Initial_poll_raises_OnDataChange_for_every_subscribed_tag asserts the initial-data push fires once per tag in the subscribe call (2 tags → 2 events with FullReference='Level' and FullReference='Temp'); Unchanged_values_do_not_raise_after_initial_poll lets the loop run ~5 cycles at 100ms with a stable register value, asserts only the initial push fires (no event spam on stable tags); Value_change_between_polls_raises_OnDataChange mutates the fake register bank between poll ticks and asserts a second event fires with the new value (verified via e.Snapshot.Value.ShouldBe((short)200)); Unsubscribe_stops_the_polling_loop captures the event count right after UnsubscribeAsync, mutates a register that would have triggered a change if polling continued, asserts the count stays the same after 400ms; SubscribeAsync_floors_intervals_below_100ms passes a 10ms interval + asserts only 1 event fires across 300ms (if the floor weren't enforced we'd see 30 — the test asserts the floor semantically by counting events on stable data); Multiple_subscriptions_fire_independently creates two subs on different tags, unsubscribes only one, mutates the other's tag, asserts only the surviving sub emits while the unsubscribed one stays at its pre-unsubscribe count. FakeTransport in this test file is scoped to FC03 only since that's all the subscription path exercises — keeps the test doubles minimal and the failure modes obvious. WaitForCountAsync helper polls a ConcurrentQueue up to a deadline, makes the tests tolerant of scheduler jitter on slow CI runners. Full solution: 0 errors, 195 tests pass (6 new subscription + 9 existing Modbus + 180 pre-existing). ModbusDriver now implements IDriver + ITagDiscovery + IReadable + IWritable + ISubscribable — five of the eight capability interfaces. IAlarmSource + IHistoryProvider remain unimplemented because Modbus has no wire-level alarm or history semantics; IHostConnectivityProbe is a plausible future addition (treat transport disconnect as a Stopped signal) but needs the socket-level connection-state tracking plumbed through IModbusTransport which is its own PR.
2026-04-18 12:03:39 -04:00
Phase 3 PR 21 — Modbus TCP driver: first native-protocol greenfield for v2. New src/Driver.Modbus project with ModbusDriver implementing IDriver + ITagDiscovery + IReadable + IWritable. Validates the driver-agnostic abstractions (IAddressSpaceBuilder, DriverAttributeInfo, DataValueSnapshot, WriteRequest/WriteResult) generalize beyond Galaxy — nothing Galaxy-specific is used here. ModbusDriverOptions carries Host/Port/UnitId/Timeout + a pre-declared tag list (Modbus has no discovery protocol — tags are configuration). IModbusTransport abstracts the socket layer so tests swap in-memory fakes; concrete ModbusTcpTransport speaks the MBAP ADU (TxId + Protocol=0 + Length + UnitId + PDU) over TcpClient, serializes requests through a semaphore for single-flight in-order responses, validates the response TxId matches, surfaces server exception PDUs as ModbusException with function code + exception code. DiscoverAsync streams one folder per driver with a BaseDataVariable per tag + DriverAttributeInfo that flags writable tags as SecurityClassification.Operate vs ViewOnly for read-only regions. ReadAsync routes per-tag by ModbusRegion: FC01 for Coils, FC02 for DiscreteInputs, FC03 for HoldingRegisters, FC04 for InputRegisters; register values decoded through System.Buffers.Binary.BinaryPrimitives (BigEndian for single-register Int16/UInt16 + two-register Int32/UInt32/Float32 per standard modbus word-swap conventions). WriteAsync uses FC05 (Write Single Coil with 0xFF00/0x0000 encoding) for booleans, FC06 (Write Single Register) for 16-bit types, FC16 (Write Multiple Registers) for 32-bit types. Unknown tag → BadNodeIdUnknown; write to InputRegister or DiscreteInput or Writable=false tag → BadNotWritable; exception during transport → BadInternalError + driver health Degraded. Subscriptions + Historian + Alarms deliberately out of scope — Modbus has no push model (subscribe would be a polling overlay, additive PR) and no history/alarm semantics at the protocol level. Tests (9 new ModbusDriverTests): InitializeAsync connects + populates the tag map + sets health=Healthy; Read Int16 from HoldingRegister returns BigEndian value; Read Float32 spans two registers BigEndian (IEEE 754 single for 25.5f round-trips exactly); Read Coil returns boolean from the bit-packed response; unknown tag name returns BadNodeIdUnknown without an exception; Write UInt16 round-trips via FC06; Write Float32 uses FC16 (two-register write verified by decoding back through the fake register bank); Write to InputRegister returns BadNotWritable; Discover streams one folder + one variable per tag with correct DriverDataType mapping (Int16/Int32→Int32, UInt16/UInt32→Int32, Float32→Float32, Bool→Boolean). FakeTransport simulates a 256-register/256-coil bank + implements the 7 function codes the driver uses. slnx updated with the new src + tests entries. Full solution post-add: 0 errors, 189 tests pass (9 Modbus + 180 pre-existing). IDriver abstraction validated against a fundamentally different protocol — Modbus TCP has no AlarmExtension, no ScanState, no IPC boundary, no historian, no LDAP — and the same builder/reader/writer contract plugged straight in. Future PRs on this driver: ISubscribable via a polling loop, IHostConnectivityProbe for dead-device detection, PLC-specific data-type extensions (Int64/BCD/string-in-registers).
2026-04-18 11:55:21 -04:00