1201d5fcfb
17 .hex fixtures captured from libplctag 1.5.2 (native 2.6.0) against otopcua-ab-server:libplctag-release, plus the CaptureFile loader, its length/alternation tests, and the re-runnable scripts/ab-capture/capture.sh. Observed and recorded in Captures/README.md "Routing observed": - Micro800 is NOT UCMM under libplctag 2.6.0: it opens a Large Forward Open (path 20 02 24 01) and reads connected; use_connected_msg=0 is ignored. - SLC500/MicroLogix/PLC-5 send Execute PCCC 0x4B unconnected and unwrapped; a configured path=1,0 never reaches the wire. - Only Large FO 0x5B was observed; no 0x54 fallback occurred. - LogixPccc is unreachable against ab_server (CIP 0x08); no fixture committed.
14 lines
1.1 KiB
Plaintext
14 lines
1.1 KiB
Plaintext
# plc5-read-n7.hex
|
|
# client : libplctag 1.5.2 (libplctag.NET wrapper; libplctag.NativeImport 1.0.41, native core 2.6.0)
|
|
# server : otopcua-ab-server:libplctag-release (ab_server from libplctag v2.7.0 + patches 0001/0002)
|
|
# profile: plc5 (host :44821)
|
|
# tag : protocol=ab_eip&gateway=10.100.0.35:44821&path=1,0&plc=plc5&name=N7:0
|
|
# session: plc5-read-n7 (captured 2026-10-07, scripts/ab-capture/capture.sh)
|
|
# frames : FULL session. PCCC 0x0F/0x01 PLC-5 typed read, twice (Initialize + Read). N7:0 held 1357.
|
|
> 65000400000000000000000000000000000000000000000001000000
|
|
< 650004008543D8A50000000000000000000000000000000001000000
|
|
> 6F002A008543D8A50000000075C4F9370000000000000000000000000100020000000000B2001A004B0220672401073DF3454350210F0073C4010000010006070002
|
|
< 6F0021008543D8A500000000000000000000000000000000000000000100020000000000B2001100CB000000073DF3454350214F0073C44D05
|
|
> 6F002A008543D8A50000000077C4F9370000000000000000000000000100020000000000B2001A004B0220672401073DF3454350210F0075C4010000010006070002
|
|
< 6F0021008543D8A500000000000000000000000000000000000000000100020000000000B2001100CB000000073DF3454350214F0075C44D05
|