17 .hex fixtures captured from libplctag 1.5.2 (native 2.6.0) against otopcua-ab-server:libplctag-release, plus the CaptureFile loader, its length/alternation tests, and the re-runnable scripts/ab-capture/capture.sh. Observed and recorded in Captures/README.md "Routing observed": - Micro800 is NOT UCMM under libplctag 2.6.0: it opens a Large Forward Open (path 20 02 24 01) and reads connected; use_connected_msg=0 is ignored. - SLC500/MicroLogix/PLC-5 send Execute PCCC 0x4B unconnected and unwrapped; a configured path=1,0 never reaches the wire. - Only Large FO 0x5B was observed; no 0x54 fallback occurred. - LogixPccc is unreachable against ab_server (CIP 0x08); no fixture committed.
12 lines
974 B
Plaintext
12 lines
974 B
Plaintext
# logix-write-dint.hex
|
|
# client : libplctag 1.5.2 (libplctag.NET wrapper; libplctag.NativeImport 1.0.41, native core 2.6.0)
|
|
# server : otopcua-ab-server:libplctag-release (ab_server from libplctag v2.7.0 + patches 0001/0002)
|
|
# profile: controllogix
|
|
# tag : protocol=ab_eip&gateway=10.100.0.35:44818&path=1,0&plc=controllogix&name=TestDINT
|
|
# session: logix-write-dint (captured 2026-10-07, scripts/ab-capture/capture.sh)
|
|
# frames : Initialize read (0x52) then Write Tag (0x4D) of 123456.
|
|
> 70002800B517D7FE000000000000000000000000000000000000000001000200A10004000B9D929FB10014000100520591085465737444494E54010000000000
|
|
< 70002000B517D7FE000000000000000000000000000000000000000001000200A1000400390C6A4CB1000C000100D2000000C40000000000
|
|
> 70002A00B517D7FE000000000000000000000000000000000000000001000200A10004000B9D929FB100160002004D0591085465737444494E54C400010040E20100
|
|
< 70001A00B517D7FE000000000000000000000000000000000000000001000200A1000400390C6A4CB10006000200CD000000
|