Joseph Doherty aa8834a231 Phase 3 PR 40 — LiveStackSmokeTests: write-roundtrip + subscribe-receives-OnDataChange against the live Galaxy. Finishes LMX #5 by exercising the IWritable + ISubscribable capability paths end-to-end through the Proxy → OtOpcUaGalaxyHost service → MXAccess → real Galaxy.
Two new facts target DelmiaReceiver_001.TestAttribute — the writable Boolean UDA on the TestMachine_001 hierarchy in this dev Galaxy. The user nominated TestMachine_001 (the deployed test-target object) as a scratch surface for live testing; ZB query showed DelmiaReceiver_001 carries one dynamic_attribute named TestAttribute (mx_data_type=1=Boolean, lock_type=0=writable, security_classification=1=Operate). Naming makes the intent obvious — the attribute exists for exactly this kind of integration testing — and Boolean keeps the assertions simple (invert, write, read back).
Write_then_read_roundtrips_a_writable_Boolean_attribute_on_TestMachine_001: reads the current value as the baseline (Galaxy may return Uncertain quality until the Engine has scanned the attribute at least once — we don't read into a typed bool until Status is Good), inverts it, writes via IWritable, then polls reads in a 5s loop until either the new value comes back or the budget expires. The scan-window poll (rather than a single read after a fixed delay) accommodates Galaxy's variable scan latency on a fresh service start. Restore-on-finally writes the original value back so re-running the test doesn't accumulate a flipped TestAttribute on the dev box (Galaxy holds UDA values across runs since they're deployed). Best-effort restore — swallows exceptions so a failure in restore doesn't mask the primary assertion.
Subscribe_fires_OnDataChange_with_initial_value_then_again_after_a_write: subscribes to the same attribute with a 250ms publishing interval, captures every OnDataChange notification onto a thread-safe ConcurrentQueue (MXAccess advisory fires on its own thread per Galaxy's COM apartment model — must not block it), waits up to 5s for the initial-value callback (per ISubscribable's contract: 'driver MAY fire OnDataChange immediately with the current value'), records the queue depth as a baseline, writes the toggled value, waits up to 8s for at least one MORE notification, then searches the queue tail for the notification carrying the toggled value (initial value may appear multiple times before the write commits — looking at the tail finds the post-write delta even if the queue grew during the wait window). Unsubscribes on finally + restores baseline.
Both tests use Convert.ToBoolean(value ?? false) to defensively handle the Boxed-vs-typed quirk in MessagePack-deserialized Galaxy values — depending on the wire encoding the Boolean might come back as System.Boolean or System.Object boxing one. Convert.ToBoolean handles both. Same pattern in OnReadValue's existing usage.
WaitForAsync helper does the loop+budget pattern shared by both tests.
PR 40 is the code side of LMX #5's final two deferred facts. To actually run them green requires re-executing from a normal (non-admin) PowerShell — the elevated-shell skip from PR 39 fires correctly under bash + sc.exe-context (verified). lmx-followups.md #5 updated to note the new facts + the run command + the one remaining genuine follow-up (alarm-condition fact when an alarm-flagged attribute is deployed on TestMachine_001).
Test posture from elevated bash: 7 LiveStackSmokeTests facts discovered (was 5; +2 new), all skip cleanly with the elevation message. Build clean.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-18 19:38:34 -04:00
..
Phase 3 PR 28 — Admin UI cert-trust management page. New /certificates route (FleetAdmin-only) surfaces the OPC UA server's PKI store rejected + trusted certs and gives operators Trust / Delete / Revoke actions so rejected client certs can be promoted without touching disk. CertTrustService reads $PkiStoreRoot/{rejected,trusted}/certs/*.der files directly via X509CertificateLoader — no Opc.Ua dependency in the Admin project, which keeps the Admin host runnable on a machine that doesn't have the full Server install locally (only needs the shared PKI directory reachable; typical deployment has Admin + Server side-by-side on the same box and PkiStoreRoot defaults match so a plain-vanilla install needs no override). CertTrustOptions bound from the Admin's 'CertTrust:PkiStoreRoot' section, default %ProgramData%\OtOpcUa\pki (matches OpcUaServerOptions.PkiStoreRoot default). Trust action moves the .der from rejected/certs/ to trusted/certs/ via File.Move(overwrite:true) — idempotent, tolerates a concurrent operator doing the same move. Delete wipes the file. Revoke removes from trusted/certs/ (Opc.Ua re-reads the Directory store on each new client handshake, so no explicit reload signal is needed; operators retry the rejected connection after trusting). Thumbprint matching is case-insensitive because X509Certificate2.Thumbprint is upper-case hex but operators copy-paste from logs that sometimes lowercase it. Malformed files in the store are logged + skipped — a single bad .der can't take the whole management page offline. Missing store directories produce empty lists rather than exceptions so a pristine install (Server never run yet, no rejected/trusted dirs yet) doesn't crash the page.
2026-04-18 14:37:55 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 3 PR 15 — alarm-condition contract in IAddressSpaceBuilder + wire OnAlarmEvent through GenericDriverNodeManager. IAddressSpaceBuilder.IVariableHandle gains MarkAsAlarmCondition(AlarmConditionInfo) which returns an IAlarmConditionSink. AlarmConditionInfo carries SourceName/InitialSeverity/InitialDescription. Concrete address-space builders (the upcoming PR 16 OPC UA server backend) materialize a sibling AlarmConditionState node on the first call; the sink receives every lifecycle transition the generic node manager forwards. GenericDriverNodeManager gains a CapturingBuilder wrapper that transparently wraps every Folder/Variable call — the wrapper observes MarkAsAlarmCondition calls without participating in materialization, captures the resulting IAlarmConditionSink into an internal source-node-id → sink ConcurrentDictionary keyed by IVariableHandle.FullReference. After DiscoverAsync completes, if the driver implements IAlarmSource the node manager subscribes to OnAlarmEvent and routes every AlarmEventArgs to the sink registered for args.SourceNodeId — unknown source ids are dropped silently (may belong to another driver or to a variable the builder chose not to flag). Dispose unsubscribes the forwarder to prevent dangling invocation-list references across node-manager rebuilds. GalaxyProxyDriver.DiscoverAsync now calls handle.MarkAsAlarmCondition(new AlarmConditionInfo(fullName, AlarmSeverity.Medium, null)) on every attr.IsAlarm=true variable — severity seed is Medium because the live Priority byte arrives through the subsequent GalaxyAlarmEvent stream (which PR 14's GalaxyAlarmTracker now emits); the Admin UI sees the severity update on the first transition. RecordingAddressSpaceBuilder in Driver.Galaxy.E2E gains a RecordedAlarmCondition list + a RecordingSink implementation that captures AlarmEventArgs for test assertion — the E2E parity suite can now verify alarm-condition registration shape in addition to folder/variable shape. Tests (4 new GenericDriverNodeManagerTests): Alarm_events_are_routed_to_the_sink_registered_for_the_matching_source_node_id — 2 alarms registered (Tank.HiHi + Heater.OverTemp), driver raises an event for Tank.HiHi, the Tank.HiHi sink captures the payload, the Heater.OverTemp sink does not (tag-scoped fan-out, not broadcast); Non_alarm_variables_do_not_register_sinks — plain Tank.Level in the same discover is not in TrackedAlarmSources; Unknown_source_node_id_is_dropped_silently — a transition for Unknown.Source doesn't reach any sink + no exception; Dispose_unsubscribes_from_OnAlarmEvent — post-dispose, a transition for a previously-registered tag is no-op because the forwarder detached. InternalsVisibleTo('ZB.MOM.WW.OtOpcUa.Core.Tests') added to Core csproj so TrackedAlarmSources internal property is visible to the test. Full solution: 0 errors, 152 unit tests pass (8 Core + 14 Proxy + 14 Admin + 24 Configuration + 6 Shared + 84 Galaxy.Host + 2 Server). PR 16 will implement the concrete OPC UA address-space builder that materializes AlarmConditionState from this contract.
2026-04-18 07:51:35 -04:00
Phase 1 Streams B–E scaffold + Phase 2 Streams A–C scaffold — 8 new projects with ~70 new tests, all green alongside the 494 v1 IntegrationTests baseline (parity preserved: no v1 tests broken; legacy OtOpcUa.Host untouched). Phase 1 finish: Configuration project (16 entities + 10 enums + DbContext + DesignTimeDbContextFactory + InitialSchema/StoredProcedures/AuthorizationGrants migrations — 8 procs including sp_PublishGeneration with MERGE on ExternalIdReservation per decision #124, sp_RollbackToGeneration cloning rows into a new published generation, sp_ValidateDraft with cross-cluster-namespace + EquipmentUuid-immutability + ZTag/SAPID reservation pre-flight, sp_ComputeGenerationDiff with CHECKSUM-based row signature — plus OtOpcUaNode/OtOpcUaAdmin SQL roles with EXECUTE grants scoped to per-principal-class proc sets and DENY UPDATE/DELETE/INSERT/SELECT on dbo schema); managed DraftValidator covering UNS segment regex, path length, EquipmentUuid immutability across generations, same-cluster namespace binding (decision #122), reservation pre-flight, EquipmentId derivation (decision #125), driver↔namespace compatibility — returning every failing rule in one pass; LiteDB local cache with round-trip + ring pruning + corruption-fast-fail; GenerationApplier with per-entity Added/Removed/Modified diff and dependency-ordered callbacks (namespace → driver → device → equipment → poll-group → tag, Removed before Added); Core project with GenericDriverNodeManager (scaffold for the Phase 2 Galaxy port) and DriverHost lifecycle registry; Server project using Microsoft.Extensions.Hosting BackgroundService replacing TopShelf, with NodeBootstrap that falls back to LiteDB cache when the central DB is unreachable (decision #79); Admin project scaffolded as Blazor Server with Bootstrap 5 sidebar layout, cookie auth, three admin roles (ConfigViewer/ConfigEditor/FleetAdmin), Cluster + Generation services fronting the stored procs. Phase 2 scaffold: Driver.Galaxy.Shared (netstandard2.0) with full MessagePack IPC contract surface — Hello version negotiation, Open/CloseSession, Heartbeat, DiscoverHierarchy + GalaxyObjectInfo/GalaxyAttributeInfo, Read/WriteValues, Subscribe/Unsubscribe/OnDataChange, AlarmSubscribe/Event/Ack, HistoryRead, HostConnectivityStatus, Recycle — plus length-prefixed framing (decision #28) with a 16 MiB cap and thread-safe FrameWriter/FrameReader; Driver.Galaxy.Host (net48) implementing the Tier C cross-cutting protections from driver-stability.md — strict PipeAcl (allow configured server SID only, explicit deny on LocalSystem + Administrators), PipeServer with caller-SID verification via pipe.RunAsClient + WindowsIdentity.GetCurrent and per-process shared-secret Hello, Galaxy-specific MemoryWatchdog (warn at max(1.5×baseline, +200 MB), soft-recycle at max(2×baseline, +200 MB), hard ceiling 1.5 GB, slope ≥5 MB/min over 30-min rolling window), RecyclePolicy (1 soft recycle per hour cap + 03:00 local daily scheduled), PostMortemMmf (1000-entry ring buffer in %ProgramData%\OtOpcUa\driver-postmortem\galaxy.mmf, survives hard crash, readable cross-process), MxAccessHandle : SafeHandle (ReleaseHandle loops Marshal.ReleaseComObject until refcount=0 then calls optional unregister callback), StaPump with responsiveness probe (BlockingCollection dispatcher for Phase 1 — real Win32 GetMessage/DispatchMessage pump slots in with the same semantics when the Galaxy code lift happens), IsExternalInit shim for init setters on .NET 4.8; Driver.Galaxy.Proxy (net10) implementing IDriver + ITagDiscovery forwarding over the IPC channel with MX data-type and security-classification mapping, plus Supervisor pieces — Backoff (5s → 15s → 60s capped, reset-on-stable-run), CircuitBreaker (3 crashes per 5 min opens; 1h → 4h → manual cooldown escalation; sticky alert doesn't auto-clear), HeartbeatMonitor (2s cadence, 3 consecutive misses = host dead per driver-stability.md). Infrastructure: docker SQL Server remapped to host port 14330 to coexist with the native MSSQL14 Galaxy ZB DB instance on 1433; NuGetAuditSuppress applied per-project for two System.Security.Cryptography.Xml advisories that only reach via EF Core Design with PrivateAssets=all (fix ships in 11.0.0-preview); .slnx gains 14 project registrations. Deferred with explicit TODOs in docs/v2/implementation/phase-2-partial-exit-evidence.md: Phase 1 Stream E Admin UI pages (Generations listing + draft-diff-publish, Equipment CRUD with OPC 40010 fields, UNS Areas/Lines tabs, ACLs + permission simulator, Generic JSON config editor, SignalR real-time, Release-Reservation + Merge-Equipment workflows, LDAP login page, AppServer smoke test per decision #142), Phase 2 Stream D (Galaxy MXAccess code lift out of legacy OtOpcUa.Host, dual-service installer, appsettings → DriverConfig migration script, legacy Host deletion — blocked by parity), Phase 2 Stream E (v1 IntegrationTests against v2 topology, Client.CLI walkthrough diff, four 2026-04-13 stability findings regression tests, adversarial review — requires live MXAccess runtime).
2026-04-17 21:35:25 -04:00
Phase 3 PR 24 — Modbus PLC data type extensions. Extends ModbusDataType beyond the textbook Int16/UInt16/Int32/UInt32/Float32 set with Int64/UInt64/Float64 (4-register types), BitInRegister (single bit within a holding register, BitIndex 0-15 LSB-first), and String (ASCII packed 2 chars per register with StringLength-driven sizing). Adds ModbusByteOrder enum on ModbusTagDefinition covering the two word-orderings that matter in the real PLC population: BigEndian (ABCD — Modbus TCP standard, Schneider PLCs that follow it strictly) and WordSwap (CDAB — Siemens S7 family, several Allen-Bradley series, some Modicon families). NormalizeWordOrder helper reverses word pairs in-place for 32-bit values and reverses all four words for 64-bit values (keeps bytes big-endian within each register, which is universal; swaps only the word positions). Internal codec surface switched from (bytes, ModbusDataType) pairs to (bytes, ModbusTagDefinition) because the tag carries the ByteOrder + BitIndex + StringLength context the codec needs; RegisterCount similarly takes the tag so strings can compute ceil(StringLength/2). DriverDataType mapping in MapDataType extended to cover the new logical types — Int64/UInt64 widen to Int32 (PR 25 follow-up: extend DriverDataType enum with Int64 to avoid precision loss), Float64 maps to DriverDataType.Float64, String maps to DriverDataType.String, BitInRegister surfaces as Boolean, all other mappings preserved. BitInRegister writes throw a deliberate InvalidOperationException with a 'read-modify-write' hint — to atomically flip a single bit the driver needs to FC03 the register, OR/AND in the bit, then FC06 it back; that's a separate PR because the bit-modify atomicity story needs a per-register mutex and optional compare-and-write semantics. Everything else (decoder paths for both byte orders, Int64/UInt64/Float64 encode + decode, bit-index extraction across both register halves, String nul-truncation on decode, String nul-padding on encode) ships here. Tests (21 new ModbusDataTypeTests): RegisterCount_returns_correct_register_count_per_type theory (10 rows covering every numeric type); RegisterCount_for_String_rounds_up_to_register_pair theory (5 rows including the 0-char edge case that returns 0 registers); Int32_BigEndian_decodes_ABCD_layout + Int32_WordSwap_decodes_CDAB_layout + Float32_WordSwap_encode_decode_roundtrips (covers the two most-common 32-bit orderings); Int64_BigEndian_roundtrips + UInt64_WordSwap_reverses_four_words (word-swap on 64-bit reverses the four-word layout explicitly, with the test computing the expected wire shape by hand rather than trusting the implementation) + Float64_roundtrips_under_word_swap (3.14159265358979 survives the round-trip with 1e-12 tolerance); BitInRegister_extracts_bit_at_index theory (6 rows including LSB, MSB, and arbitrary bits in a multi-bit mask); BitInRegister_write_is_not_supported_in_PR24 (asserts the exception message steers the reader to the 'read-modify-write' follow-up); String_decodes_ASCII_packed_two_chars_per_register (decodes 'HELLO!' from 3 packed registers with the 'HELLO!'u8 test-only UTF-8 literal which happens to equal the ASCII bytes for this ASCII input); String_decode_truncates_at_first_nul ('Hi' padded with nuls reads back as 'Hi'); String_encode_nul_pads_remaining_bytes (short input writes remaining bytes as 0). Full solution: 0 errors, 217 unit + integration tests pass (22 + 30 new Modbus = 52 Modbus total, 165 pre-existing). ModbusDriver capability footprint now matches the most common industrial PLC workloads — Siemens S7 + Allen-Bradley + Modicon all supported via ByteOrder config without driver forks.
2026-04-18 12:27:12 -04:00