Files
lmxopcua/tests/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware.Tests/ProgramAlarmWriterTests.cs
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00

83 lines
2.8 KiB
C#

using System;
using Shouldly;
using Xunit;
using ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware;
using ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware.Backend;
namespace ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Host.Tests
{
/// <summary>
/// PR C.2 — pins the env-var contract that gates whether the sidecar boots an
/// alarm-event writer. Default-on (when the historian itself is enabled) so a
/// fresh deploy picks up the writer without a service-config edit; explicit
/// <c>false</c> opts a read-only deployment out.
/// </summary>
[Trait("Category", "Unit")]
public sealed class ProgramAlarmWriterTests
{
[Fact]
public void BuildAlarmWriter_returns_writer_when_env_unset()
{
using var _ = ScopedEnv("OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED", null);
var writer = Program.BuildAlarmWriter();
writer.ShouldNotBeNull();
writer.ShouldBeOfType<AahClientManagedAlarmEventWriter>();
}
[Theory]
[InlineData("true")]
[InlineData("True")]
[InlineData("TRUE")]
public void BuildAlarmWriter_returns_writer_when_env_explicitly_true(string value)
{
using var _ = ScopedEnv("OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED", value);
var writer = Program.BuildAlarmWriter();
writer.ShouldNotBeNull();
}
[Theory]
[InlineData("false")]
[InlineData("False")]
[InlineData("FALSE")]
public void BuildAlarmWriter_returns_null_when_env_false(string value)
{
using var _ = ScopedEnv("OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED", value);
var writer = Program.BuildAlarmWriter();
writer.ShouldBeNull();
}
[Fact]
public void BuildAlarmWriter_treats_unrecognized_value_as_enabled()
{
// Anything other than the literal "false" (case-insensitive) keeps the writer
// wired — fail-open under accidental misconfiguration so an alarm-write deploy
// doesn't silently lose alarms because of a typo.
using var _ = ScopedEnv("OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED", "yes");
var writer = Program.BuildAlarmWriter();
writer.ShouldNotBeNull();
}
private static IDisposable ScopedEnv(string name, string? value)
{
var prior = Environment.GetEnvironmentVariable(name);
Environment.SetEnvironmentVariable(name, value);
return new DisposableAction(() => Environment.SetEnvironmentVariable(name, prior));
}
private sealed class DisposableAction : IDisposable
{
private readonly Action _action;
public DisposableAction(Action action) { _action = action; }
public void Dispose() => _action();
}
}
}